frieling MILKchiller II User manual

OWNER’S MANUAL
Model Number:
US/Canada: 0601
MILKchiller™ II
by

2
Important Safeguards
When using an electrical appliance, basic safety precautions should
always be followed to reduce the risk of fire, electrical shock and injury to
persons, including the following:
1. Read all instructions before using appliance.
2. Close supervision is necessary when any appliance is used near
children.
3. This appliance is not for use by children.
4. The cord to this appliance should be plugged into a 120V AC
electrical outlet only.
5. Do not operate any appliance with a damaged cord or plug or after
the appliance malfunctions, or has been dropped or damaged in
any manner. Contact Consumer Service for return authorization,
examination, repair or adjustment.
6. If this appliance malfunctions during use, immediately unplug the
cord from the outlet. Do not attempt to repair the malfunctioning
appliance.
7. Unplug unit when not in use and before cleaning.
8. Do not let the power supply hang over edge of table or counter.
9. Use caution when transporting MILKchiller™ II.
10. Do not place on or near a hot gas or electric burner or in a heated
oven.
11. The use of accessory attachments is not recommended by the
manufacturer as it may cause injuries.
12. Use MILKchiller™ II unit only with the provided base and on a
flat surface.
SAVE THESE INSTRUCTIONS

3
Important Safeguards
(cont.)
CAUTION: Do not block the cooling fan in the back of the unit nor
the exhaust ports on the side of the MILKchiller™ II. Allow ample
space for air circulation.
CAUTION: Do not immerse the power-supply, cord, or
appliance in water or any other liquid.
CAUTION: Do not use metal scouring pads to clean the
appliance. Pieces of the pad may break off and touch electrical
parts.
CAUTION: Do not pour water or any liquid into the chilling
chamber of the MILKchiller™ II.
CAUTION: The room temperature for normal operation of the
MILKchiller™ II is below 30°C / 86°F. We cannot guarantee
proper functioning of the MILKchiller™ II in a room or
environment above these temperatures.
Polarized
Plug
This appliance has a polarized plug (one blade is wider than the
other). As a safety feature to reduce the risk of electrical shock,
this plug is intended to fit in a polarized outlet only one way. If
the plug does not fit fully in the outlet, reverse the plug. If it still
does not fit, contact a qualified electrician. Do not attempt to
modify the plug in any way.
Power Cord
Instructions
A long power cord is provided so that the MILKchiller™ II can be
located away from the power outlet. Care must be taken to ensure
the cord does not become entangled or located where tripping can
occur.

4
MILKchiller™ II
Parts and Accessories
1
2
6
7
3
54 8
A complete list of parts/accessories and ordering details are
located at the end of the owner’s manual.
Parts List
Item No.
1MILKchiller™ II unit 0601
2Power Supply and Plug 0713
3Base with Drip Tray Cup 0721
4Drip Tray Insert 0710
5Drip Tray Metal platform 0711
6Air Filter 0705
7 Wire Tie 0725
8 Pipette -

5
Congratulations!
MILKchiller™ II is the ideal solution for your beverage station
because it…
• Maintains dairy products at a safe temperature of 5°C / 41ºF
or below.
• Features an LCD displaying 8 types of dairy products:
WHOLE; CREAM; ½ & ½; 1%; 2%; SKIM; FAT-FREE; SOY
in 5 languages: English, French, German, Italian and Spanish.
• Accommodates standard ½ gallon dairy cartons.
• Will also accommodate the dishwasher safe,
MILKchiller™ II Refillable Container.
• Dispenses dairy products with a simple press of a button.
• Eliminates mess and waste.
• Is easy to operate and to replace the dairy container.
Before Using for the First Time
1. Carefully unpack the MILKchiller™ II from the box.
2. Read all of the instructions included in this manual.
3. Remove all the packing material including the white wrappers
protecting the stainless steel components.
4. Make sure the MILKchiller™ II is unplugged and the power
switch is in the OFF position.
5. Wipe exterior surfaces with a damp cloth. Dry thoroughly with a
soft cloth. DO NOT use harsh or abrasive cleansers as these can
damage the exterior surfaces.
CAUTION: Do not immerse the power supply, the cord, or the
appliance in water or any other liquid.
6. Before first use, the MILKchiller™ II Refillable Container (if
using) should be hand washed in warm, soapy water or in the
dishwasher.
7. Thoroughly dry the Refillable Container and lid.

6
The MILKchiller™ II is now ready for use.
Plug the Power Supply Connector into the Power Inlet on the
MILKchiller™ II control panel. Connect the power supply to the
power cord and plug it into the wall outlet. Set the Power Switch to
ON.
Power Supply
Connector
Power Inlet
Power Switch
Upon start up, the LCD will alternately flash COOLING, LOW and
WHOLE until the MILKchiller™ II has reached the safety standard
temperature. (The “LOW” message will disappear when the full milk
container is inserted into the chilling chamber.)
When it has reached the safety standard temperature, the LCD will
display the default setting “WHOLE”.
For more information on the setting display, please see the section
DISPLAY SETTINGS and CONTROL PANEL FUNCTIONS.

7
Fine Tuning the Low Level Indicator
The Low Level Indicator has been calibrated
to trigger when the liquid is down to
approximately 18 fluid ounces (1/4 of total).
Once this amount is reached, the LOW
indicator flashes on the display. The Low
Level Indication can be adjusted to trigger
for more liquid remaining in the carton if
desired.
1. Locate the calibration screw on
the underside of the MILKchiller™ II
just behind the drip tray.
2. Fill a container 1/4 full or more with liquid.
This is the approximate amount of dairy product
remaining in the container when the LOW
indicator flashes on the display.
Place container in the MILKchiller™ II and close the
lid.
3. Place the MILKchiller™ II on a flat
surface that will provide access to the
calibration screw. We suggest using an
inside corner of a counter, or pushing
two tables together leaving 2 inches
between them for access to the screw.
4. Using a flat-head screwdriver,
SLOWLY adjust screw on the bottom in a
clockwise manner just until the LOW
indicator is flashing.
5. Further adjust the screw ½ turn
to complete the calibration.
If, after time, the LOW indicator does not
flash at the desired liquid level, readjust the
calibration screw as outlined above.

8
How to assemble Dispensing Sets for all milk containers:
standard ½ gallon plastic, refillable plastic container or
cardboard container
To ensure maximum sanitary conditions, please wear rubber gloves when
handling the disposable tubes. Also, please prevent contact with the lower
section of the tube.
Insert the long flexible or stainless steel tube into the extension of the plug.
Insert the plug with the tube into the spout of the container with the long
tube reaching down to the bottom of the milk container. The plug needs to
be positioned with the smaller hole at 12 o’clock and the raised hole at 6
o’clock.
How To Insert Dispensing Set into
the Refillable Plastic Container:
1. Unscrew lid from container.
2. Fill container with dairy product up to
the MAX Fill Line.
3. Screw on lid.
4. Insert dispensing set for plastic
container with attached long tube into
opening in lid. Insert the plug
assembly by positioning the smaller
hole at 12 o’clock and the raised hole
at 6 o’clock.
5. The MILKchiller™ II can now be
loaded with Refillable Plastic
Container filled with dairy product.
How To Insert Disposable Dispensing
Set into Standard Paper Half Gallon
Container:
1. Unscrew the cap.
2. Insert plug for plastic container with
attached long tube into the pour spout.
Insert the plug assembly by positioning
the smaller hole at 12 o’clock and the
raised hole at 6 o’clock.
3. The MILKchiller™ II can now be loaded
with a ½ gallon paper carton of dairy
product.

9
How To Insert Dispensing Set into the
standard ½ Gallon Plastic Container:
1. Unscrew lid from container.
2. Pour a minimum of 2 oz. of milk out of
the container*.
3. Insert dispensing set for plastic container
with attached long tube into opening in
lid. Insert the plug assembly by
positioning the smaller hole at 12 o’clock
and the raised hole at 6 o’clock
4. The MILKchiller™ II can now be loaded
with a standard ½ gallon plastic container
of diary product.
* Standard ½ gallon plastic containers are filled to the rim with milk and the
container is slightly bulging. Since the MILKchiller™ II chilling chamber is designed
tight for optimal cooling contact with the container, milk will be squeezed out of the
container while loading the chilling chamber if no milk was poured out prior to
inserting the container.
Load Container into MILKchiller™ II
It is required to keep all dairy products refrigerated prior to use in the
MILKchiller™ II. If using shelf stable milk, the MILKchiller™ II will
not operate until the milk has cooled to the safe temperature
specification.
To load the container into the MILKchiller™ II, regardless of the
type of container:
1. Lift the lid by pulling upward on the dispensing spout.
2. Orient the container so that the smaller of the two holes of the plug
inserted in the milk container is pointing to the front of the
machine.
3. Insert the container into the chilling chamber until it sits on the
bottom surface. Insert short flexible tube into the plug.
4.Insert the Air Hose Fitting into the smaller of the two open holes.
The small hole with the Air Hose Fitting should be in the 12 o’
clock position. See drawings below and on page 11 and 12 for
orientation. Press down for a tight fit.
5. Lower the lid to close the machine.

10
MILKchiller™ II Refillable Container
Air Hose
Straw Guide
Paper Half Gallon Container
Air Hose
Dispensing Tube Guide

11
Plastic Half Gallon Container
Orient the handle of the plastic container to the front
of the chilling chamber. This will ensure maximum
surface contact against the chiller plate.
Air Hose
Dispensing Tube Guide
Please remember to pour out 2 oz. of liquid prior to loading plastic
½ gallon container into MILKchiller™ II.

12
Control Panel Functions
The MILKchiller™ II is programmed for use worldwide. The LCD
displays the dairy contents in 5 different languages.
The MILKchiller™ II must be initialized before use by first setting
the language and then setting the contents.
Reset
Contents
Language
Power Input
Temperature
Display
0
Power Switch
Language Button – Button 2
ENGLISH
Sets the language in which the dairy
contents are displayed. Pressing
the button cycles through the 5
language options:
ENGLISH, GERMAN, ITALIAN,
FRENCH, SPANISH.
To set the LANGUAGE: Stop pressing the Language Button when the
desired language is displayed. After a few seconds the default content of
WHOLE (or the equivalent in another language) will be displayed.

13
Contents Button – Button 1
CREAM
Sets the display to show the
contents of the container in the
MILKchiller™ II.
Pressing the button cycles through
the 8 types of dairy product:
WHOLE; CREAM; ½ & ½; 1%;
2%; SKIM; FAT-FREE; SOY.
To set the CONTENTS: Stop pressing the Contents Button when the
desired dairy type is displayed.
To Change the CONTENTS display: Press the CONTENTS button to
cycle through the dairy types, stopping on the desired type to display.
Reset Button – Button 3, internal button, for operator use only.
By pressing the internal button with a small sharp object such as a
paper clip, the display is reset to the manufacturer’s default settings.
The default settings are ENGLISH and WHOLE. After resetting the
MILKchiller™ II, the LANGUAGE button and CONTENTS button
must be set to the desired display settings.
Temperature Display Button – for operator use only.
Pressing and holding the
Temperature Display button shows
the temperature of the dairy product
on the LCD in ºF and ºC. This
41ºF, 5ºC is for inspection purposes only.
Releasing the button returns the
display to the last setting.
Power Input – connector of the power supply, provided with each unit.
Power Switch – ON / OFF power switch. When the MILKchiller™ II
is powered off and on, the display retains its last setting.

14
Display Settings
The LCD on the front of the machine has many uses.
1. It shows the contents of the MILKchiller™ II in daily use.
2. It displays the temperature of the liquid when Temperature
Button is pressed.
3. It communicates the status of the machine:
When the unit is first starting
up, the LCD flashes COOLING
until it has reached cooling
temperature.
COOLING If after 2 hour
s the MILKchiller™ II does not
reach cooling temperature,
SERVICE is flashed on the
LCD, and the pump will not
operate.
LOW
When the level of the liquid
becomes low, the machine
notifies the operator by flashing
LOW.
The operator is alerted that the
dairy product needs to be refilled
soon.
SERVICE
LCD, the MILKchiller™ II
should be returned for service.
This indicates the machine is not
cooling to the safe temperature
specification, and the dairy
product may not be safe to ingest.

15
Dispensing Dairy Product
The push button on the left side of the MILKchiller™ II causes
the dairy product to be delivered through the dispensing spout.
Dairy product will be delivered for as long as the button is
depressed (up to 60 seconds). There might be a slight delay
between pushing the button and the delivery of the dairy product.
Dispensing
Spout
Push
Button to
Dispense
Dairy
Product
PLEASE NOTE: The force of depressing the Push Button may cause the
LOW level indicator to flash. When the button is released, the LOW level
indicator will disappear.
Removing Empty Carton or Container
The MILKchiller™ II notifies the operator that the content of the
container is getting low by flashing LOW on the display. To
remove an empty carton or container:
1. Lift the lid by pulling upward on the dispensing spout.
2. Disengage the Air Hose Fitting and Air Hose from the Disposable
Plug.
3. Lift the empty container from the chilling chamber.
4. Dispose of empty container and Disposable Set according to
local recycling laws and policies.
5. Clean the Chilling Cavity as outlined in the Care and Cleaning
Section.
To refill the MILKchiller™ II with a full carton or container,
follow the instructions found in section INSERT DISPOSABLE
DISPENSING SET and load container.

16
Start the new Day
Start the new day with a full milk container, clean dispensing tube
set, and a clean drip tray (containing a little bit of water).
Fasten Base to Countertop
The base is equipped with two keyholes for locking
it to the countertop, if desired.
1. Place base at desired location
on counter top.
2. Mark screw locations at the
bottom of the keyhole.
3. Remove base. Drill pilot holes
into countertop.
4. Replace base, and drill screws
into countertop to lock down
base.
To move location of base:
1. Back out screws part way to unlock base.
2. Move base forward to clear screw head.
3. Lift base off counter top.

17
Lock MILKchiller™ II to Base
Place the MILKchiller™ II on the base, inserting the feet into
the corresponding holes in the base.
At the back of the unit and base, there are locking tabs that can be used
to secure the MILKchiller™ II to the base. Insert the provided wire tie
through both openings in the locking tabs and fasten. A small pad lock
can be looped in the locking tabs for added security.
PLEASE NOTE: Do not over-tighten the wire tie, as some movement
is required.

18
Drip Tray Features
The Drip Tray is an integral
part of the base.
The Drip Tray insert is
provided so that when
the base is fastened to the
countertop, the insert can be
removed and emptied.
Drip Tray Insert
Hole in Drip Tray
There is a fitting located on the
underside of the Drip Tray to
which a hose can be attached.
A Drain Hose can be routed
beneath the counter to a bin to
collect larger amounts of excess
liquid.
In this case, the Drip Tray Insert
is removed and not used.

19
Replace the Air Filter
The Air Filter located at the lower back of the MILKchiller™ II
filters the air being used to dispense the dairy product. It is
recommended
to change the filter at least once every three months; more often if the
environment requires and the Air Filter turns dark in color.
To Replace the Air Filter:
1. Gently pull upwards on the tab extending above the plastic grill.
2. Lift filter out of grill and dispose.
3. Load replacement filter by sliding it along the back wall and into the
slot between the grill and the housing.
4. It may be necessary to loosen the 4 screws in the grill to free or load
the filter. Be sure to tighten the screws after loading the Air Filter.
Air Filter
Screws

20
Care and Cleaning
CAUTION: Do not immerse the power supply, cord, or appliance in
water or any other liquid.
CAUTION: Do not use metal scouring pads to clean the appliance.
Pieces of the pad may break off and touch electrical parts.
CAUTION: Do not pour water or any liquid into the chilling chamber
of the MILKchiller™ II.
1. Unplug the MILKchiller™ II, open the lid and allow all parts to
reach room temperature before cleaning.
2. Clean the outside of the MILKchiller™ II with a clean, damp sponge.
Do not use an abrasive cleaner, as it may damage the exterior finish.
3. Clean the inside of the MILKchiller™ II with a clean sponge and
a small amount of mild dish detergent. Wipe dry with a paper or
cloth towel.
4. The MILKchiller™ II Refillable Container and Lid can be
washed with warm, soapy water or placed in the dishwasher.
Dry thoroughly before next use.
5. The base and drip tray insert can be washed with warm, soapy water
or placed in the dishwasher.
6. The Drip Tray Metal Platform can be washed with warm, soapy
water or placed in the dishwasher.
7. If using the drip tray and hose, run hot soapy water through the drip
tray and hose into the large bin to clean.
8. Do not clean the Disposable Dispensing Systems. They are
designed to be thrown away with each new milk container/carton.
9. The stainless steel tubes need to be cleaned after each use with the
included brush in soapy warm water or in the dishwasher.
10. A pipette is provided to clean the Disposable Dispensing Tubes
when “in a bind”. Starting with a new Disposable Dispensing Set
each time the dairy product is replaced eliminates contamination
risks. The exchange is easy, fast, safe, and compliant with health
department regulations. Please recycle used tubes and plugs.
11. Let all parts dry thoroughly prior to plugging in the MILKchiller™ II
and using.
11. Regularly clean fan and fan grill with a damp cloth to remove dust.
This manual suits for next models
1
Table of contents
Other frieling Kitchen Appliance manuals
Popular Kitchen Appliance manuals by other brands

KVS MORAVIA
KVS MORAVIA 9106 Operation and maintenance manual

Dometic
Dometic Delta15F Installation and operating manual

Kompernass
Kompernass KH 1144 operating instructions

OBH Nordica
OBH Nordica 6889 Instructions of use

Unold
Unold Mini Allround 38650 Instructions for use

Breville
Breville BSP400 instructions