manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. FUCHS
  6. •
  7. Tools
  8. •
  9. FUCHS CASSIDA HD Operating instructions

FUCHS CASSIDA HD Operating instructions

Other FUCHS Tools manuals

FUCHS CASSIDA HD Operating instructions

FUCHS

FUCHS CASSIDA HD Operating instructions

Popular Tools manuals by other brands

AGI Westfield MKX16 Assembly manual

AGI

AGI Westfield MKX16 Assembly manual

GYS HAND-DUCTION 056923 Translation of the original instructions

GYS

GYS HAND-DUCTION 056923 Translation of the original instructions

Grizzly H7583 instruction manual

Grizzly

Grizzly H7583 instruction manual

Sealey VS0462.V2 instructions

Sealey

Sealey VS0462.V2 instructions

Makita HR2650 instruction manual

Makita

Makita HR2650 instruction manual

Forza 1100H Series manual

Forza

Forza 1100H Series manual

Aventics EBS-PI operating instructions

Aventics

Aventics EBS-PI operating instructions

Martor SECUNORM 175 quick start guide

Martor

Martor SECUNORM 175 quick start guide

jbc N4473 instruction manual

jbc

jbc N4473 instruction manual

FEINMETALL FZWZ-SET-001 quick start guide

FEINMETALL

FEINMETALL FZWZ-SET-001 quick start guide

Worx Professional Sonicrafter WU676 Original instructions

Worx Professional

Worx Professional Sonicrafter WU676 Original instructions

Gage Bilt GB713SH Original instructions

Gage Bilt

Gage Bilt GB713SH Original instructions

Hilti DX 9-ENP Original operating instructions

Hilti

Hilti DX 9-ENP Original operating instructions

norbar NORTRONIC 34399 Operator's manual

norbar

norbar NORTRONIC 34399 Operator's manual

BGS technic 8578 manual

BGS technic

BGS technic 8578 manual

axing BWZ 5-02 Operation instructions

axing

axing BWZ 5-02 Operation instructions

Makita DHR241 instruction manual

Makita

Makita DHR241 instruction manual

Motor Guard JMB-1250 instructions

Motor Guard

Motor Guard JMB-1250 instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

THE SYSTEM
HOW TO USE
THE CASSIDA
HD GREASE GUN
Safer food with
CASSIDA food grade lubricants
HD two-handed grease gun
(pre-lubricated with food grade lubricant) Armoured pipe with grip coupling
THE COMBINATION
Special piston shape ensures
that the cartridge can be
completely emptied.
500g
SR-cartridge
0602078_Cassida Englisch_A4.qxd 20.02.2012 13:47 Seite 1
How to use the SYSTEM REINER two-handed
CASSIDA HD GREASE GUN
*) Minimum permissible bending radius: 100 mm; permissible dynamic operating pressure: 400 bar
General instructions for use
•Before starting lubrication:
Ensure that the grease nipple and the grip coupling are clean.
•During lubrication:
The grip coupling/armoured pipe must sit upright on the nipple.
If you hold the grip coupling at an angle, the nipple is not fully
covered. Keep checking the amount of lubricant being extruded.
•After lubrication:
Do not pull the mouthpiece/grip coupling off the nipple, but bend it
sideways. Nipples which do not work properly must be replaced as
soon as possible.
Important safety information
Our SYSTEM REINER CASSIDA HD GREASE GUN carries the GS label,
which means it has been checked for safety.
It is designed to operate at pressures of 400 bar, in accordance with
DIN 1283, and has a large built-in safety margin. The design of the
grease gun means it requires less operating force than conventional
grease guns.
Twist the screw top
off the cartridge.
Depending on how the cartridge was
filled, a small quantity of air may be
trapped in the area of the screw thread.
Gently press the centre of the piston to
push out this air in order to ensure that
the lubricant reaches the pump unit
immediately.
Attach the armoured pipe* to the
press head. This grease gun allows a
maximum pressure of 400 bar.
WARNING! Check the lubricating
channels, grease nipples and the points
of lubrication before you start operating
the press with both hands.
Screw in the cartridge up to the stop
line. Operate the press until lubricant
appears at the end of the armoured pipe
(3-5 strokes).
Now the press is ready to use. The pump
unit is refilled by vacuum after each
stroke.
At each stroke, you should open the
press smoothly and keep it open for as
long as it takes, to fill the pump unit
again. Depending on the temperature
and type of lubricant used, it may take
up to three seconds for the piston
chamber to be filled completely.
When you start to feel resistance
closing the hand lever, this indicates
the chamber contains the right amount
of lubricant.
You can check the level of lubricant in
the cartridge at any time (see diagram).
The special piston shape ensures
that the cartridge is being completely
emptied.
Deutsches
Gebrauchsmuster
HDP: 8709845
Europ. Patent
EHP: 0250890
0602078_Cassida Englisch_A4.qxd 20.02.2012 13:47 Seite 2
FUCHS LUBRICANTS (UK) PLC
New Century Street,
Hanley, Stoke-on-Trent,
ST1 5HU
Phone: +44 (0)1782 203 700
Fax: +44 (0)1782 202 072
email: [email protected]
www.fuchslubricants.com/cassida