Fujitsu ETERNUS AF250 S2 User manual

FUJITSU Storage
ETERNUS AF250 S2,
ETERNUS AF250
All-Flash Arrays
Configuration Guide (Basic)
P3AG-1832-04ENZ0

This page is intentionally left blank.

Preface
Fujitsu would like to thank you for purchasing the FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 (here-
inafter referred to as ETERNUS AF).
The ETERNUS AF is designed to be connected to Fujitsu servers (Fujitsu SPARC Servers, PRIMEQUEST, or PRI-
MERGY) or non-Fujitsu servers.
This manual describes how to install the ETERNUS AF and how to start the operation.
This manual is intended for use of the ETERNUS AF in regions other than Japan.
Please carefully review the information outlined in this manual.
Fourth Edition
December 2017
About This Manual
Organization
This manual is composed of the following eleven chapters:
•"Chapter 1 Component Names" (page 17)
This chapter provides components names of the ETERNUS AF.
•"Chapter 2 Rack Installation" (page 22)
This chapter describes the procedure for installing the ETERNUS AF in a rack.
•"Chapter 3 Checking the Configuration Environment" (page 34)
This chapter describes the environment required for system configuration.
•"Chapter 4 Connecting Cables" (page 44)
This chapter explains how to connect various cables to the ETERNUS AF.
•"Chapter 5 General Settings" (page 55)
This chapter describes the basic settings for the ETERNUS AF.
•"Chapter 6 Monitoring Settings" (page 85)
This chapter describes the settings required to monitor the ETERNUS AF.
•"Chapter 7 Power Control Setup" (page 105)
This chapter describes the settings required for power control of the ETERNUS AF.
•"Chapter 8 SAN Connection Settings" (page 109)
This chapter describes the settings required to use the ETERNUS AF with a SAN connection.
•"Chapter 9 Advanced Copy Settings" (page 141)
This chapter describes the settings required to operate Advanced Copy.
•"Chapter 10 System Status Check" (page 152)
This chapter describes the status check for the ETERNUS AF after system configuration.
•"Chapter 11 Solution Configuration" (page 158)
This chapter describes storage solutions using the ETERNUS AF.
3
FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic)
Copyright 2017 FUJITSU LIMITED
P3AG-1832-04ENZ0

Registered Trademarks and Trademarks
•All SPARC trademarks are used under license from SPARC International, Inc. and are trademarks or regis-
tered trademarks of that company in the United States and other countries.
•UNIX is a registered trademark of The Open Group in the United States and other countries.
•Microsoft, Windows, Windows Server, and Internet Explorer are either registered trademarks or trademarks
of Microsoft Corporation in the United States and/or other countries.
•Oracle and Java are registered trademarks of Oracle and/or its affiliates.
•HP-UX is a trademark of Hewlett-Packard Company in the U.S. and other countries.
•Mozilla, Firefox, and the Mozilla and Firefox logos are trademarks or registered trademarks of the Mozilla
Foundation in the United States and other countries.
•Red Hat and Red Hat Enterprise Linux are trademarks of Red Hat, Inc., registered in the U.S. and other
countries.
•Linux® is the registered trademark of Linus Torvalds in the U.S. and other countries.
•SUSE is a registered trademark of Novell, Inc. in the United States and other countries.
•IBM, AIX, and Tivoli are trademarks of International Business Machines Corporation, registered in many ju-
risdictions worldwide.
•VMware, VMware logos, Virtual SMP, and vMotion are either registered trademarks or trademarks of
VMware, Inc. in the U.S. and/or other countries.
•Arcserve is a registered trademark or trademark of Arcserve (USA), LLC.
•NetVault is a registered trademark of Dell Inc. in the United States and other countries.
•EMC and NetWorker are either registered trademarks or trademarks of EMC Corporation in the United
States and/or other countries.
•The company names, product names and service names mentioned in this document are registered trade-
marks or trademarks of their respective companies.
•Microsoft product screen shot(s) reprinted with permission from Microsoft Corporation.
Naming Conventions
■Product Names
•Oracle Solaris might be described as Solaris, Solaris Operating System, or Solaris OS.
•The following abbreviations are used for Microsoft® Windows Server®.
Product name Abbreviation
Microsoft® Windows Server® 2008 Datacenter
Microsoft® Windows Server® 2008 R2 Datacenter
Windows Server 2008
Microsoft® Windows Server® 2008 Enterprise
Microsoft® Windows Server® 2008 R2 Enterprise
Microsoft® Windows Server® 2008 Standard
Microsoft® Windows Server® 2008 R2 Standard
Microsoft® Windows Server® 2008 for Itanium-Based Systems
Microsoft® Windows Server® 2008 R2 for Itanium-Based Systems
Microsoft® Windows Server® 2008 HPC Edition
Microsoft® Windows Server® 2008 R2 HPC Edition
Preface
4
FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic)
Copyright 2017 FUJITSU LIMITED
P3AG-1832-04ENZ0

Product name Abbreviation
Microsoft® Windows Server® 2012 Datacenter
Microsoft® Windows Server® 2012 R2 Datacenter
Windows Server 2012
Microsoft® Windows Server® 2012 Standard
Microsoft® Windows Server® 2012 R2 Standard
Microsoft® Windows Server® 2012 Essentials
Microsoft® Windows Server® 2012 R2 Essentials
Microsoft® Windows Server® 2016 Datacenter
Microsoft® Windows Server® 2016 Standard
Windows Server 2016
•The following abbreviations are used for Red Hat Linux.
Product name Abbreviation
Red Hat Enterprise Linux 5 (for x86)
Red Hat Enterprise Linux 5 (for Intel64)
Red Hat Enterprise Linux 5
Red Hat Enterprise Linux 6 (for x86)
Red Hat Enterprise Linux 6 (for Intel64)
Red Hat Enterprise Linux 6
Red Hat Enterprise Linux 7 (for Intel 64) Red Hat Enterprise Linux 7
■Symbols Used in This Manual
The following symbols are used throughout this manual:
This indicates information for the user to note when using the ETERNUS AF. Please be
sure to read this information.
This indicates supplementary and reference information.
■Abbreviations Used in This Manual
•"ETERNUS AF250 S2" refers to the FUJITSU Storage ETERNUS AF250 S2 and "ETERNUS AF250" refers to the
FUJITSU Storage ETERNUS AF250.
•"ETERNUS AF" refers to the ETERNUS AF250 S2 and the ETERNUS AF250.
•"CA" refers to a host interface module that is used in an ETERNUS AF to connect to a server.
•"Host Bus Adapter (HBA)" refers to an interface module that is normally used in a server to connect to
ETERNUS AF storage systems.
•Trademark symbols such as ™ and ® are omitted in this document.
Preface
5
FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic)
Copyright 2017 FUJITSU LIMITED
P3AG-1832-04ENZ0

Warning Signs
Warning signs are shown throughout this manual in order to prevent injury to the user and/or material dam-
age. These signs are composed of a symbol and a message describing the recommended level of caution.
The following explains the symbol, its level of caution, and its meaning as used in this manual.
This symbol indicates the possibility of serious or fatal injury if the ETERNUS AF is not
used properly.
This symbol indicates the possibility of minor or moderate personal injury, as well as
damage to the ETERNUS AF and/or to other users and their property, if the ETERNUS AF
is not used properly.
This symbol indicates IMPORTANT information for the user to note when using the ETER-
NUS AF.
The following symbols are used to indicate the type of warnings or cautions being described.
Electric Shock
The triangle emphasizes the urgency of the WARNING and CAUTION contents. Inside
the triangle and above it are details concerning the symbol (e.g. Electrical Shock).
No Disassembly
The barred "Do Not..." circle warns against certain actions. The action which must be
avoided is both illustrated inside the barred circle and written above it (e.g. No Disas-
sembly).
Unplug
The black "Must Do..." circle indicates actions that must be taken. The required ac-
tion is both illustrated inside the black disk and written above it (e.g. Unplug).
Preface
6
FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic)
Copyright 2017 FUJITSU LIMITED
P3AG-1832-04ENZ0

How Warnings are Presented in This Manual
A message is written beside the symbol indicating the caution level. This message is marked with a vertical
ribbon in the left margin, to distinguish this warning from ordinary descriptions.
A display example is shown here.
Warning level indicator
Warning type indicator
Warning details
To avoid damaging the ETERNUS storage system, pay attention to the
following points when cleaning the ETERNUS storage system:
- Make sure to disconnect the power when cleaning.
- Be careful that no liquid seeps into the ETERNUS storage system
when using cleaners, etc.
- Do not use alcohol or other solvents to clean the ETERNUS storage system.
Warning layout ribbon
Example warning
CAUTION Do
Preface
7
FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic)
Copyright 2017 FUJITSU LIMITED
P3AG-1832-04ENZ0

Warning Labels and Manufacturer's Labels
Warning labels, manufacturer's labels, and a device ID label are found in the ETERNUS AF, as shown in the
example below.
Never remove these labels from the equipment or allow them to become dirty.
Controller Enclosure
Manufacturer’s label
The model name and
the serial number are
listed.
Device ID label
The model name and the serial number
are listed.
Preface
8
FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic)
Copyright 2017 FUJITSU LIMITED
P3AG-1832-04ENZ0

Drive Enclosures
Power Distribution Units (for Regions other than the EMEIA, Central American, and Car-
ibbean Regions)
•Power distribution unit (AC200-240V, 1U)
Preface
9
FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic)
Copyright 2017 FUJITSU LIMITED
P3AG-1832-04ENZ0

•Power distribution unit (AC200-240V, 2U)
Preface
10
FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic)
Copyright 2017 FUJITSU LIMITED
P3AG-1832-04ENZ0

Table of Contents
Chapter 1 Component Names 17
1.1 Controller Enclosure ..................................................................................................................... 17
1.1.1 Front...................................................................................................................................................................17
1.1.2 Rear ....................................................................................................................................................................18
1.2 Drive Enclosures ........................................................................................................................... 18
1.2.1 Front...................................................................................................................................................................19
1.2.2 Rear ....................................................................................................................................................................19
1.3 Power Distribution Units (for Regions other than the EMEIA, Central American, and Caribbean Re-
gions) ........................................................................................................................................... 20
1.3.1 Power Distribution Units (1U).............................................................................................................................20
1.3.2 Power Distribution Units (2U).............................................................................................................................20
Chapter 2 Rack Installation 22
2.1 Power Distribution Unit Installation (for Regions other than the EMEIA, Central American, and Car-
ibbean Regions) ........................................................................................................................... 23
2.1.1 Installing Power Distribution Unit (1U)...............................................................................................................24
2.1.2 Installing Power Distribution Unit (2U)...............................................................................................................26
2.2 Controller Enclosure Installation (for Regions other than the EMEIA, Central American, and Carib-
bean Regions) .............................................................................................................................. 28
2.3 Drive Enclosure Installation (for Regions other than the EMEIA, Central American, and Caribbean
Regions) ....................................................................................................................................... 31
Chapter 3 Checking the Configuration Environment 34
3.1 System Configuration Example..................................................................................................... 34
3.2 Server Connection Preparation ..................................................................................................... 35
3.2.1 Driver Preparation ..............................................................................................................................................35
3.2.2 Driver Installation ...............................................................................................................................................36
3.2.3 iSCSI Initiator Parameter Settings .......................................................................................................................37
3.3 Preparing the PC Terminal for Setup............................................................................................. 40
3.4 LAN Connection Preparation for Operation Management............................................................. 41
3.4.1 Completing and Attaching the Network Setting Label ........................................................................................41
3.4.2 LAN Related Specifications..................................................................................................................................42
11
FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic)
Copyright 2017 FUJITSU LIMITED
P3AG-1832-04ENZ0

Chapter 4 Connecting Cables 44
4.1 Host Interface Cable Connection................................................................................................... 44
4.2 Drive Enclosure Connection .......................................................................................................... 47
4.3 Power Synchronized Unit Connection ........................................................................................... 49
4.4 Power Cord Connection................................................................................................................. 49
4.4.1 When No Power Distribution Units Are Installed.................................................................................................50
4.4.2 When 1U Power Distribution Unit Is Installed (for Regions other than the EMEIA, Central American, and Carib-
bean Regions).......................................................................................................................................................51
4.4.3 When 2U Power Distribution Unit Is Installed (for Regions other than the EMEIA, Central American, and Carib-
bean Regions).......................................................................................................................................................52
Chapter 5 General Settings 55
5.1 PC Terminal Connection................................................................................................................ 58
5.2 Powering On................................................................................................................................. 59
5.2.1 Switching On and Off the Main Line Switch on the Power Distribution Unit........................................................59
5.2.2 Switching On and Off the PSU Switch on the Power Supply Unit .........................................................................60
5.2.3 Powering On .......................................................................................................................................................61
5.3 ETERNUS Web GUI Startup ............................................................................................................ 62
5.4 Storage Management (Initial Setup 1)......................................................................................... 64
5.5 LAN Cable Connection (for Operation Management).................................................................... 70
5.6 Firewall Settings........................................................................................................................... 72
5.7 RAID Configuration Settings ......................................................................................................... 74
5.7.1 RAID Group Creation ...........................................................................................................................................74
5.7.2 Operation Volume Creation.................................................................................................................................76
5.7.3 Generation Management Volume (SDV) Creation...............................................................................................79
5.7.4 Copy Data Destination Volume (SDPV) Creation .................................................................................................80
5.7.5 Hot Spare Registration........................................................................................................................................82
Chapter 6 Monitoring Settings 85
6.1 Event Notification Setup............................................................................................................... 85
6.2 Various Notification Settings ........................................................................................................ 86
6.2.1 SNMP Trap Setup ................................................................................................................................................86
6.2.2 E-mail Setup .......................................................................................................................................................93
6.2.3 Syslog Setup .......................................................................................................................................................95
Table of Contents
12
FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic)
Copyright 2017 FUJITSU LIMITED
P3AG-1832-04ENZ0

6.3 Remote Support Setup.................................................................................................................. 96
6.3.1 Remote Support (by AIS Connect) Setup .............................................................................................................97
6.3.2 Remote Support (by REMCS) Setup .....................................................................................................................98
6.4 Audit Log Setup.......................................................................................................................... 100
6.5 Monitoring Server (SNMP Manager) Settings ............................................................................. 101
6.6 Transmission Test Execution....................................................................................................... 102
6.6.1 SNMP Trap Test .................................................................................................................................................102
6.6.2 Send Test E-mail ...............................................................................................................................................103
Chapter 7 Power Control Setup 105
7.1 Setup of the Auto Power Function and/or the Power Resume Function ...................................... 105
7.2 Connection Setup for Power Synchronized Unit .......................................................................... 107
7.3 Wake On LAN Settings................................................................................................................ 107
Chapter 8 SAN Connection Settings 109
8.1 Connection Settings for the ETERNUS AF .................................................................................... 109
8.1.1 Host Response Settings.....................................................................................................................................109
8.1.2 Host Affinity Settings ........................................................................................................................................110
8.1.3 CA Reset Group Settings....................................................................................................................................118
8.2 Server Connection Setup............................................................................................................. 119
8.2.1 iSCSI Initiator Parameter Settings (Connection Information Settings)...............................................................119
8.2.2 LUN Recognition Check.....................................................................................................................................128
8.2.3 Disk Partition Settings ......................................................................................................................................130
Chapter 9 Advanced Copy Settings 141
9.1 Advanced Copy Basic Settings .................................................................................................... 141
9.1.1 Copy Priority Settings........................................................................................................................................141
9.1.2 Copy Table Size Settings....................................................................................................................................143
9.1.3 Copy Parameter Settings ..................................................................................................................................145
9.2 Performing a Copy (SnapOPC+) .................................................................................................. 146
Chapter 10 System Status Check 152
10.1 Checking the Component Status............................................................................................... 152
10.2 Checking the RAID Groups ........................................................................................................ 153
Table of Contents
13
FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic)
Copyright 2017 FUJITSU LIMITED
P3AG-1832-04ENZ0

10.3 Checking the Volumes.............................................................................................................. 154
10.4 Checking the Copy Sessions...................................................................................................... 155
10.5 Checking the LUNs ................................................................................................................... 155
10.6 Powering Off ............................................................................................................................ 156
Chapter 11 Solution Configuration 158
11.1 Continuous Business ................................................................................................................ 158
11.1.1 Remote Copy Operations for the Storage System (Copies between ETERNUS AF Storage Systems) ................158
11.1.2 Automatic Switching Operation of the Storage Systems (Storage Cluster) ......................................................160
11.2 Performance/Tuning................................................................................................................. 162
11.3 Virtualization Platform ............................................................................................................. 164
11.3.1 Oracle VM Linkage ..........................................................................................................................................164
11.3.2 VMware Linkage .............................................................................................................................................165
11.3.3 Microsoft Linkage ...........................................................................................................................................167
11.4 Security .................................................................................................................................... 168
Table of Contents
14
FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic)
Copyright 2017 FUJITSU LIMITED
P3AG-1832-04ENZ0

List of Figures
Figure 1.1 Front View of a Controller Enclosure.........................................................................................................17
Figure 1.2 Rear View of a Controller Enclosure ..........................................................................................................18
Figure 1.3 Front View of a Drive Enclosure ................................................................................................................19
Figure 1.4 Rear View of a Drive Enclosure .................................................................................................................19
Figure 1.5 Power Distribution Unit (AC200-240V, 1U, 4 Outlets)...............................................................................20
Figure 1.6 Power Distribution Unit (AC200-240V, 2U, 12 Outlets).............................................................................20
Figure 1.7 Power Distribution Unit (AC200-240V, 2U, 16 Outlets).............................................................................21
Figure 3.1 System Configuration Example.................................................................................................................34
Figure 3.2 Network Setting Label..............................................................................................................................41
Figure 5.1 Example of Differential Backup Settings with SnapOPC+..........................................................................56
Figure 5.2 Example of Creating Operation Volume and Backup Volume ...................................................................57
Figure 5.3 PC Terminal Connection for Initial Setup ..................................................................................................58
Figure 5.4 ON Position (Marked "|") of the Main Line Switches on a 1U Power Distribution Unit ..............................59
Figure 5.5 ON Position (Marked "|") of the Main Line Switches on a 2U Power Distribution Unit ..............................59
Figure 5.6 ON Position (Marked "|") of the PSU Switch on a Power Supply Unit ........................................................60
Figure 5.7 RAID Group Creation.................................................................................................................................74
Figure 5.8 Operation Volume Creation ......................................................................................................................76
Figure 5.9 Generation Management Volume (SDV) Creation ....................................................................................79
Figure 5.10 Copy Data Destination Volume (SDPV) Creation.......................................................................................80
Figure 8.1 Connection Configuration with Servers...................................................................................................119
Figure 11.1 Solution — Continuous Business (Copy between ETERNUS AF storage systems)......................................158
Figure 11.2 Solution — Continuous Business (Storage Cluster) ..................................................................................160
Figure 11.3 Solution — Performance/Tuning ..............................................................................................................162
Figure 11.4 Solution — Virtualization Platform (Oracle VM Linkage)..........................................................................164
Figure 11.5 Solution — Virtualization Platform (VMware Linkage).............................................................................165
Figure 11.6 Solution — Virtualization Platform (Microsoft Linkage)...........................................................................167
15
FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic)
Copyright 2017 FUJITSU LIMITED
P3AG-1832-04ENZ0

List of Tables
Table 3.1 Server (Host) Environment.......................................................................................................................35
Table 3.2 LAN Port Availability.................................................................................................................................42
Table 5.1 RAID Group Creation.................................................................................................................................74
Table 5.2 Operation Volume Creation ......................................................................................................................77
Table 7.1 ETERNUS AF Operation according to the Settings of the Auto Power Function and the Power Resume
Function.................................................................................................................................................105
16
FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic)
Copyright 2017 FUJITSU LIMITED
P3AG-1832-04ENZ0

Chapter 1
Component Names
This chapter provides the component names of the ETERNUS AF.
1.1 Controller Enclosure
An operation panel and drives are installed in the front of the ETERNUS AF (controller enclosure). Controllers
and power supply units are installed in the rear.
1.1.1 Front
This section provides the names of the components in the front of a controller enclosure.
Figure 1.1 Front View of a Controller Enclosure
1
3 3
2
1. Operation panel
2. Drive
3. Flange cover
17
FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic)
Copyright 2017 FUJITSU LIMITED
P3AG-1832-04ENZ0

1.1.2 Rear
This section provides the names of the components in the rear of a controller enclosure.
Figure 1.2 Rear View of a Controller Enclosure
12
3567 6734 588
9 10
4
1. Controller (CM#0)
2. Controller (CM#1)
3. PWC port
4. Host interface (CA#0)
5. Drive interface (OUT) port
6. RMT (LAN) port
7. Host interface (CA#1)
8. MNT (LAN) port
9. Power supply unit (PSU#0)
10. Power supply unit (PSU#1)
1.2 Drive Enclosures
Drives and an operation panel are installed in the front of the drive enclosure. I/O modules and power supply
units are installed in the rear.
Chapter 1 Component Names
1.2 Drive Enclosures
18
FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic)
Copyright 2017 FUJITSU LIMITED
P3AG-1832-04ENZ0

1.2.1 Front
This section provides the names of the components in the front of a drive enclosure.
Figure 1.3 Front View of a Drive Enclosure
1
3 3
2
1. Operation panel
2. Drive
3. Flange cover
1.2.2 Rear
This section provides the names of the components in the rear of a drive enclosure.
Figure 1.4 Rear View of a Drive Enclosure
3
12
45
3
1. I/O module (IOM#0)
2. I/O module (IOM#1)
3. Drive interface (IN) port
4. Power supply unit (PSU#0)
5. Power supply unit (PSU#1)
Chapter 1 Component Names
1.2 Drive Enclosures
19
FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic)
Copyright 2017 FUJITSU LIMITED
P3AG-1832-04ENZ0

1.3 Power Distribution Units (for Regions other than the EMEIA,
Central American, and Caribbean Regions)
There are two sizes for power distribution units: 1U and 2U.
1.3.1 Power Distribution Units (1U)
The 1U power distribution unit has four outlets and two inlets.
1.3.1.1 Power Distribution Unit (AC200-240V, 1U, 4 Outlets)
Figure 1.5 Power Distribution Unit (AC200-240V, 1U, 4 Outlets)
3
2
1
1. Main line switch
2. Outlet (OUTPUT)
3. Inlet (INPUT)
1.3.2 Power Distribution Units (2U)
2U power distribution units are available in two types: a 12 outlet type and a 16 outlet type.
1.3.2.1 Power Distribution Unit (AC200-240V, 2U, 12 Outlets)
There are 12 outlets.
Figure 1.6 Power Distribution Unit (AC200-240V, 2U, 12 Outlets)
2
1
1. Main line switch
2. Outlet (OUTPUT)
Chapter 1 Component Names
1.3 Power Distribution Units (for Regions other than the EMEIA, Central American, and Caribbean Regions)
20
FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic)
Copyright 2017 FUJITSU LIMITED