INSTALLATION INSTRUCTIONS
MCU-005 CONTROL UNIT
The following installation instructions cover how to install the MCU-005 Control Unit.
Before installation, check the notes below regarding running of the cables.
The MCU-005 is designed to be flush-mounted in a console or panel.
Note regarding running of the cables
To reduce stress on the connectors, prevent accidental disconnection and also to prevent water
intrusion, make sure that the wiring at the rear of the control unit meets the following recommen-
dations.
• Cables should not be run upwards from the units. Make sure the cable are run downwards.
• Cables should be bundled together with sufficient slack to allow service and maintenance.
• Bundled cables should be secured in a manner that prevents stress on the connectors, caused
by heave and pitch.
The figures below show examples of cabling, along with the above recommendations.
Packing list
MCU-005 MODIFICATION KIT (Type: OP19-19, Code: 001-506-900)
Note: “*” indicates revision/version number.
Part name Type Code Amount
CONTROL UNIT MCU-005 1
PANEL REMOVER 19-028-3124 100-340-471-10 1
LAN CABLE ASSEMBLY MOD-Z072-050+ 001-167-890-10 1
PACKING BB 19-028-1581 100-340-742-10 1
SELF TAPPING SCREW 4x20 SUS304 000-158-850-10 4
FLUSH MOUTNING TEMPLATE C42-00703-* 000-167-223-1* 1
Cables should not be routed in
a way that allows moisture or
water to drip into the unit.
Cables should not be hung
freely. This causes stress
on the connectors and may
cause disconnections.
Cables should be bundled
with a wire-tie and secured
against the inside of the
console or to a bulkhead.
There should be enough
slack in the cables to allow
service and maintenance.
MCU-005 MCU-005
Other
equipment
MCU-005
Other
equipment