2. Chacking after installation
First, do the followings:First, do the followings:
First, do the followings:First, do the followings:
First, do the followings:
1.Checkforsecureconnections.
2. Check power supply voltage 21V to 31V.
3. Find MMSI No. of the ship, check the specification of the DSC, MF or MF/HF, and check
the remote station function setting, ON or OFF.
Check all the settings.Check all the settings.
Check all the settings.Check all the settings.
Check all the settings.
There are two kinds of settings: one is made through [#SETUP] menu and the other is made with DIP
switches. Refer to Page 4-4 and 4-17.
1.All the daily test results are OK? Refer to [DAILY TEST] on Page 5-2.
2. MMSI No. is set correctly? Refer to [System setup] on Page 4-14.
3. The position data on DSC stanby screen are entered correctly? Refer to [Position setup] on
Page 4-8 and [Setting for connection with navigational aids] on Page 4-19.
Check transmitting power of the radiotelephone for rated value.Check transmitting power of the radiotelephone for rated value.
Check transmitting power of the radiotelephone for rated value.Check transmitting power of the radiotelephone for rated value.
Check transmitting power of the radiotelephone for rated value.
1.The transmitting power of the MF/HF radiotelephone with DSC is the specified value?
Refer to [Frequency and power measurement] on Page 6-3.
2.Inthecase of remote-station specification, the transmitting power of the MF/HF radiotele-
phone with hand set is the specified value?
3.Actual DSC transmission test result of the MF/HF radiotelephone is OK? Make the test call
“CALL TYPE” to coast radio stations using [TEST CALL].
ExplanaExplana
ExplanaExplana
Explanations to usertions to user
tions to usertions to user
tions to users has ha
s has ha
s havv
vv
ve been made thore been made thor
e been made thore been made thor
e been made thoroughloughl
oughloughl
oughly?y?
y?y?
y?
General
If any malfunction occurs, turn off the power for a time to clear RAMIf any malfunction occurs, turn off the power for a time to clear RAM
If any malfunction occurs, turn off the power for a time to clear RAMIf any malfunction occurs, turn off the power for a time to clear RAM
If any malfunction occurs, turn off the power for a time to clear RAM
memormemor
memormemor
memoryy
yy
y. No memor. No memor
. No memor. No memor
. No memory bacy bac
y bacy bac
y backup bakup ba
kup bakup ba
kup battertter
ttertter
ttery is used in the DSC-60.y is used in the DSC-60.
y is used in the DSC-60.y is used in the DSC-60.
y is used in the DSC-60.