Information in this document can be modified without notice.
Edition 07.2020 ..
03
5
Quick Start Guide
Door Multi-point Locking System Automatic Smart Access Controlled
Door manufacturer
. Make sure you can manually open and close the door from the interior using either the prole cylinder
knob, or interior operating handle before installing the access control system
. Follow the correct wire diagram from this document
. After installing the access control system, make sure to test the system before shipping it to site:
- Connect a V DC power supply to the system
- Press the buttons + OK on the remote or + on the keypad
- If using a Secure Connect, try activating the lock by bridging V/ on Secure Connect R
- Check that the three LED (green/blue/red) are lit up on the keypad/ngerprint scanner
. Identify all the outside wiring before shipping it to site
(Wiring that will be connected to power supply or any rd party access control on site)
. If a third party is doing the installation of the door or the access control system,
make sure to send this document
Door installer
. After the installation of the door, the outside wiring needs to be accessible for
the access control installer to complete the job
. The insulation foam must not cover the Secure Connect R
Access control installer
. Follow the correct installation diagram from this document
. Power supply used must be stabilized V DC with minimum ,A
Any dierence in voltage may cause
malfunction and damage the system!
* Do not install the SECUREconnect if conditions require a higher protection class than IP