• Ensure the Energizer is fully protected from rain, condensaon and other sources of moisture.
• Electric animal fences and their ancillary equipment shall be installed, operated and maintained in a
manner that minimizes danger to persons, animals or their surroundings.
• Do NOT become entangled in the fence. Avoid electric fence construcons that are likely to lead to
the entanglement of animals or persons.
• WARNING - INSTALLERS /USERS SHOULD NOTE:
Avoid contacng the fence with the head, mouth, neck or
torso. Do not climb over, through or under a mul-wire electric
fence. Use a gate or a specially designed crossing point.
• An electric animal fence shall not be supplied from two separate energizers or from independent
fence circuits of the same energizer.
• For any two separate electric animal fences, each supplied from a separate energizer independently
med, the distance between the wires of the two electric animal fences shall be at least 2.5m. If
this gap is to be closed, this shall be effected by means of electrically non-conducve material or an
isolated metal barrier.
• Barbed wire or razor wire shall not be electrified by an energizer.
• A non-electrified fence incorporang barbed wire or razor wire may be used to support one or more
off-set electrified wires of an electric animal fence. The supporng devices for the electrified wires
shall be constructed so as to ensure that these wires are posioned at a minimum distance of 150
mm from the vercal plane of the non-electrified wires. The barbed wire and razor wire shall be
earthed at regular intervals.
• Follow the energizer manufacturer’s recommendaons regarding earthing.
• A distance of at least 10 m (33 ) shall be be maintaned between the energizer earth electrode and
any other earthing system connected pasrts such as the power suplly system protecve earth or
telecommunicaons system earth.
• Connecng leads that are run inside buildings shall be effecvely insulated from the earther
structural parts of the building. This may be achieved by using insulated high voltage cable.
• Connecng leads that are run underground shall be run in conduit of insulang material or else
insulated high voltage lead-out cable shall be used. Care must be taken to avoid damage to the
connecng leads due to the effects of animal hooves or tractor wheels sinking into the ground.
• Connecng leads shall not be installed in the same conduit as the mains supply wiring,
communicaon cables or data cables.
• Connecng leads and electric animal fence wires shall not cross above overhead power or
communicaon lines.
• Crossings with overhead power lines shall be avoided wherever possible. If such a crossing cannot
be avoided it shall be made underneath the power line and as nearly as possible at right angles to it.
• If connecng leads and electric animal fence wires are installed near an overhead power line, the
clearances shall not be less than those shown in the table following.
Minimum clearances from power lines for electric animal fences
Power line Voltage V Clearance m
Less than or equal to 1 000 3
Greater than 1 000 and less than or equal to 33 000 4
Greater than 33 000 8
• If connecng leads and electric animal fence wires are installed near an overhead power line, their
height above the ground shall not exceed 3 m
This height applies either side of the orthogonal projecon of the outermost conductors of the
power line on the ground surface, for a distance of:-
-2 m for power lines operang at a nominal voltage not exceeding 1 000 V;
-15 m for power lines operang at a nominal voltage exceeding 1 000 V.