If you are not familiar with the Mag-
nascanner, it is recommended that you
view the Video that accompanied this
unit before beginning this checklist. To
prepare the Magnascanner for use...
Y U MUST:
❏1. Assemble unit and move to desired
location. Make necessary arrangements
of surrounding furniture and equipment.
(See Site Selection, Page 7.) Attac
cables necessary for remote consoles,
multiunit slaving, or control relays.
❏2. Connect unit to power source and
observe LCD panel. T e unit will begin
t e self test sequence automatically
w en power is connected. Correct any
problems reported. (See Self-Diagnostic
Tests, Page10.)
❏3. Determine optimum program based
on your particular application. (See Pro-
grams, Page 35.)
❏4. Set unit to desired program (See
Supervisor Adjustments, Program, Page
14.)
❏5. Determine sensitivity setting
required, using t e alarm level reading
and sample test objects selected for
your application. Be t oroug ; perform
t e test at various elevations and orien-
tations for objects t at produce t e ig -
est alarm level readings. (See Supervi-
sor Adjustments, Alarm Level Reading,
Page 15.)
❏6. Set sensitivity to value determined
in step 6.2 (See Supervisor Adjustments,
Sensitivity, Page14.)
❏7. Return to Operate Mode by pressing
PERATE touc pad.
❏8. Perform verifications test using
selected objects. (See Supervisor
Responsibilities, Page 16.)
STANDARD SETUP AND
PERATI N PR CEDURE
Y U MAY ALS :
❏9. If multiple unit operation is being uti-
lized, verify units are properly inter-
leaved. (See Multiple Unit Operation,
Page 38.)
❏10. If unit appears noisy, i.e. more t an
two LED s persistently displayed on bar
grap , furt er adjustments are required,
proceed to Step 11. If unit appears
quiet, proceed to Step 13.
❏11. Adjust video filter until noise sub-
sides. (See Installation Adjustments,
Video Filter, Page 13.)
❏12. Repeat steps 4-8.
❏13. Adjust tone to desired level. (See
Installation Adjustments, Tone, Page 12.)
❏14. Adjust volume to desired level. (see
Operating Instructions, Volume, Page 5.)
❏15. Alter access codes, if desired. (See
Installation Adjustments. Alter Access
Code #1 and #2, Page 13.)
SECURITY
When used in a security (weapons detection)
application, it is important that the following
procedures be followed:
1. Determine t e security level appropriate to t e
application.
2. Select test object(s) t at will allow calibration
and verification of t e desired settings.
3. Maintain t e Operation Work S eet s own on
Page 34 of t is booklet.
4. Using t e same test objects, verify t e calibra-
tion daily and any time t e equipment is moved
or t e operating environment c anges.
5. Seek corrective action immediately for any
problems or performance deficiencies and report
problems/deficiencies to t e sales representative
and manufacturer as well.