Quick-Start Guide
GCT
External Pump
READ FIRST BEFORE OPERATION
The GCT External Pump is a personal safety device designed to extend the capabilities of
Gas Clip Technologies’diusion gas detectors (Single Gas Clip, Single Gas Clip Plus, Multi
Gas Clip, MGC Simple and MGC Simple Plus). Before operation, ensure that you have been
properly trained on the use and daily testing of the device and the appropriate actions to
take in the event of an alarm condition.
READ GCT EXTERNAL PUMP USER’S MANUAL BEFORE OPERATION
Entry Description
1Infrared Communication Window
2 Audible Alarm
3 Power LED
4 Power Button
5 Charging LED
6 Flow LED
7 Alligator Clip
8 Gas Inlet Port
9 Pellet Filter
10 Hydrophobic Filter
11 Certication Label
12 Model and Serial Label
13 Gas Outlet Port
14 Charging Port
Set Up
Connect the 3 ft. hose from the gas outlet port to
a Gas Clip Technologies detector with a calibration
cap. Next, connect the 10 ft. sampling hose from
the gas inlet port to the diusion stone. Accessories,
such as the Quick Disconnect, Remote Sampling
Probe or Telescoping Sampling Probe, can also be
attached to the GCT External Pump with various
lengths of sampling hose (up to 75 ft.).
Included in the box: GCT External Pump, charger, 3 ft. hose, 10 ft. hose, stainless steel
diusion stone, 10 additional lters (5 hydrophobic & 5 particulate)
Device Components
Turning On the Device
To activate, press and hold down the power button for 5 seconds. Once the
device is activated, the start-up sequence will display the following behavior:
1. Power LED is green and begins to ash slowly.
2. Audible Alarm beeps once.
3. Flow LED is green and begins to ash slowly.
For ow, power and charging status, refer to LED Indicators section.
Blocked Flow Test
Before each day’s use, conduct a blocked ow test to ensure the pump is fully
operational. With the power on, block the free end of the sampling hose which
is attached to the gas inlet port. The device will display the following behavior:
1. Pump motor shuts down.
2. Audible alarm beeps continuously indicating a ow fault.
3. Flow LED turns red and ashes quickly.
Upon successful completion of the blocked ow test, press the power button
to reactivate the device.
Bump Test
Before each day’s use, complete a bump test of the detector connected to
the GCT External Pump. Refer to the GCT External Pump User’s Manual for
instructions.
Turning O the Device
Press and hold down the power button for 5 seconds until the 3 LEDs (power
LED, ow LED, charging LED) turn o, then release the button.
In the event of a low battery warning, exit the
work area immediately since the GCT External
Pump could turn o at any time.
Low Battery Warning
A fast, red intermittent ash of the power LED
with the audible alarm beep every 10 seconds
indicates that (on average) 20 minutes
of operation remains. However, the time
remaining can vary due to several dierent
factors.
LED Indicators
Contact Information:
QSG-GCT XP v1.01
A
S
S
E
M
B
L
E
D
I
N
U
S
A
Additional Questions?
For additional information on the GCT External Pump regarding
programming, bump testing, maintenance, etc., please refer to the GCT
External Pump User’s Manual. The manual and other helpful videos &
information are available for viewing or download at www.gascliptech.com.
Gas Clip Technologies, Inc.
305 W. FM 1382, Suite 540, Cedar Hill, TX 75104 USA
Phone: 1.972.775.7577 • Toll Free: 1.877.525.0808 • Fax: 1.972.775.2483
E-mail: [email protected] • Website: www.gascliptech.com
LED Pattern Description Status
Flow LED _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
**************************
* *_ _ * * _ _* *_ _ * * _ _
LED OFF
GREEN solid
RED fast ash & beep
Pump motor is OFF
Pump is ON, normal operation
Warning: Pump is blocked
Power
LED
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _
During Pump Operation:
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _
*________ _ _ _ _ _ _
* _______*_ _ _ _ _ _ _
* * * _ _ _ _ * * * _ _ _ _
* * * * * *_ _ * * * * * *_ _
* * * _ _ _* * * _ _ _* * * _ _
*_*_*_*_*_*_*_*_*_*_*_
LED OFF
LED OFF (Flow LED solid GREEN)
ORANGE slow ash every 2 sec.
ORANGE ash every sec.
RED fast ash & beep every 10 sec.
RED faster ash & beep every 5 sec.
RED very fast ash & beep every 2 sec.
RED very fast ash & very fast beep
Power OFF mode
Battery has > 40%
Between 20% to 40%
Between < 20%
Warning: < 20 min. left
Warning: < 10 min. left
Warning: < 5 min. left
Powering down
Charging
LED
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _
* * * * _ _ _ _ * * * * _ _ _ _
*_ __ _ _ _ _ _ _ _ _ _ _ _ _
LED OFF
ORANGE ash equal on and o
GREEN slow ash every 2 sec.
Not charging
Charging in progress
Fully charged

This manual suits for next models

1

Popular Safety Equipment manuals by other brands

Lanex PB-20 instruction manual

Lanex

Lanex PB-20 instruction manual

SKYLOTEC ANCHOR ROPES Instructions for use

SKYLOTEC

SKYLOTEC ANCHOR ROPES Instructions for use

Besto Buoyancy Aid 50N Instructions for use

Besto

Besto Buoyancy Aid 50N Instructions for use

TEUFELBERGER NODUS Manufacturer's information and instructions for use

TEUFELBERGER

TEUFELBERGER NODUS Manufacturer's information and instructions for use

Troy Lee Designs Tbone Product owners manual

Troy Lee Designs

Troy Lee Designs Tbone Product owners manual

Innova Xtirpa Instruction and safety manual

Innova

Innova Xtirpa Instruction and safety manual

bolle SAFETY B810 quick start guide

bolle SAFETY

bolle SAFETY B810 quick start guide

SHENZHEN FANHAI SANJIANG ELECTRONICS A9060T instruction manual

SHENZHEN FANHAI SANJIANG ELECTRONICS

SHENZHEN FANHAI SANJIANG ELECTRONICS A9060T instruction manual

Hiltron security POWER8E Installation and use manual

Hiltron security

Hiltron security POWER8E Installation and use manual

Salewa MTN SPIKE user manual

Salewa

Salewa MTN SPIKE user manual

Hatco B-950P installation guide

Hatco

Hatco B-950P installation guide

Sitec TX MATIC operating manual

Sitec

Sitec TX MATIC operating manual

TEUFELBERGER GRIP 12 Manufacturer's information and instructions for use

TEUFELBERGER

TEUFELBERGER GRIP 12 Manufacturer's information and instructions for use

MSA PremAire System Operation and instructions

MSA

MSA PremAire System Operation and instructions

AMC 1022M Series instruction manual

AMC

AMC 1022M Series instruction manual

Trinity CASS S3 Assembly manual

Trinity

Trinity CASS S3 Assembly manual

CMC Helitack HotSeat quick guide

CMC

CMC Helitack HotSeat quick guide

ACM SAFETY D200 Instructions and warnings

ACM

ACM SAFETY D200 Instructions and warnings

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.