GasDog GD400 Series User manual

GD400
explosion proof portable
gas detector
GD400 series is a high-performance portable gas detect or that
can detect multiple gases (Oxygen compounds VOC, combustible gas and
toxic gas) at the same time and has man down alarm function. The device
has humanized operation functions such as one-key security d etection, one-
key storage, automatic image flipping, as well as the man down alarm
function; With optional Bluetooth transmission function, allowing safety
personnel to obtain real-time data and the alarm status. It has obtained
international IECEX, ATEX explosion-proof certification a nd Chinese
explosion-proof certification; As it passed the antistatic t est, and the
protection level reaches IP67; With safer product design and the module
design which makes the detection faster, and the compact ergonomic design
makes the device easy carrying; What’s more, the d evice is with built in
pump, thereby improving the protection to a new Level.
The explosion-proof Grade of the SKY3000 series is Ex ia IIC T4 Ga,
which is applicable to the explosive gas mixture zone 0, zone 1, and
zone 2 of the factory with grades ⅡA , ⅡB , and ⅡC and temperature
group T1~T4.
GD400
Explosion Proof Portable Gas Detector
1

Product Advantage
Rugged and durable
Specialized in Gas Detection
For 16 Years
The instrument can effectively resist a three-meter drop
The protection level of the instrument reaches IP67
The instrument has passed the EMC anti-static interference test and can work normally in
the walkie-talkie environment
Multiple security protection
The man down alarm function has upgraded the
safety of underground operators
Password protection function prevents non-operators
from modifying menu parameters
With safety reminder function, sound and light vibration
alarm function, let operators work without worries
Simultaneous measurement of multiple gases, multiple
numerical display
The instrument can detect 1-5 gases at the same time
Real-time value, TWA, STEL, MAX, MIN multiple numerical display
n
The high and low alarm latched function allows the operator to
better capture the sudden change of the gas concentratio value
Explosion-proof circuit design, safe and reliable
The instrument has got IECEX, ATEX, explosion-proof certificates and the
explosion-proof level reaches Exia IICT4 Ga
2

Product specifications
Large screen display, flexible detection system, multiple filtering devices
The screen can be automatically turned 180 degrees, which is convenient for viewing in special
operating environments
Built-in powerful sampling pump, fast detection speed
Can be connected 20m sampling tube externally, which is convenient for long-distance or confined
space detection
Pump suction use, to provide operators with more reliable protection
With a water trap filter, it can effectively filter water, oil, dust and other impurities. It can also be used in
harsh industrial environments such as coal mines and petroleum fields
Powerful function, more user-friendly operation
Beautiful and friendly user interface, reasonable and easy-to-use interactive mode
e
Optional Bluetooth function, data can be transmitted to the mobile phone or PC in real tim
Standard storage function, one-click data export, convenient for users to analyze
Unique modifiable ID identification function, convenient for users to allocate and manage the instrument
Support PPM and mg/m3 gas unit switch, the concentration value is automatically converted by the system
A full range of automatic detection functions, automatic prompts for voltage, pump failure alarms, etc.,
more comfortable to use One-key security detection
one-key open storage, automatic image flip
Support each channel sensor to restore the factory setting separately
Support multi-language including English.Chinese and etc.
Sampling method
Gas type
Measure range
Resolution
Response time
Precsiion
Language
Automatically test and
calibrate after power-on
Unit
Disaply
Backlight
Data record
Alarm
Pump suction
Oxygen, Combustible gas, Carbon monoxide, Hydrogen sulfide, etc different gases as
customers' requirements.
O2: 0-30%VOL, EX: 0-100%LEL, CO: 0-1000PPM, H2S: 0-100PPM,etc different
measure ranges as customers' requirements.
O2: 0.1%VOL, EX: 1%LEL, CO: 1PPM, H2S: 0.1PPM, etc different resolutions
according to measure ranges.
≤30 seconds
≤±2%F.S except for special gases
Chinese/English/Russian(More language can be customized)
Including reset, maximum value (MAX), minimum value (MIN), STEL, TWA value
PPM and mg/m3 can be switched and displayed by one key, and the concentration value
is automatically converted by the system
monochrome graphics (160 x96) ,screen can be automatically flipped
y The backlight time can be manually set, and will be turned on automaticall when
an alarm is issued
Can store 100,000 sets data, the storage interval is adjustable from 5 to 3600
seconds, data can be exported, with data cable
95dB buzzer (@30cm), vibration alarm and flashing red LED and alarm status
indication on the screen, alarm latched; diagnostic alarm and battery undervoltage
alarm, pump block alarm; man down alarm, with early warning and optional real-
time remote Bluetooth notification function
Principle Catalytic combustion, Electrochemistry, IR, PID, etc according to different sensors.
3

Product configuration
Standard accessories:
Gas detector 1 piece
12V/1A DC power adapter 1 piece
USB cable 1 piece
User manual 1 piece
warranty card 1 piece
Filter 1 piece
Aluminum suitcase 1 piece
Battery
Working hours
Charger
Explosion-proof grade
Certification
(EU regulations)
Protection grade
Working temperature
Humidity
Environmental pressure
Size
Weight
3.7V rechargeable lithium battery, battery capacity 2200mA
More than 30 hours in continuous pumping mode
Travel charger with DC interface, charging time < 4 hours
IECEx: Ex ia IIC T4 Ga ATEX: II 1G Ex ia IIC T4 Ga
2004/34/UE (ATEX)
IP67
-20℃~+50℃
0~95%RH(no condensation)
86~106Kpa
157*84.5*59.5mm (including back clip/water trap filter) (length * width * height)
365g (including battery, belt clip and filter )
Detected gasmeasure rangeOptional ranges
Normal gas types and paramaters (Other gases are not listed can be customized)
Resolution Response time
Flammable gas(EX)
Oxygen(O2)
Carbon monoxide(CO)
Hydrogen sulfide(H2S)
Ammonia(NH3)
Chlorine(CL2)
Hydrogen Chloride(HCL)
Nitric oxide(NO)
Nitrogen dioxide(NO2)
formaldehyde(CH2O)
Ozone(O3)
Carbon dioxide(CO2)
0-100%LEL
0-30%VOL
0-1000ppm
0-100ppm
0-100ppm
0-10ppm
0-20ppm
0-100ppm
0-20ppm
0-10ppm
0-10ppm
0-2000ppm
0-100%VOL
0-25%VOL
0-2000ppm
0-1000ppm
0-200ppm
0-100ppm
0-100ppm
0-250ppm
0-100ppm
0-50ppm
0-100ppm
0-100%VOL
0.1%LEL/0.1%VOL
0.01%VOL/0.1%VOL
0.1ppm/1ppm
0.01ppm/0.1ppm
0.01ppm/0.1ppm
0.01ppm/0.1ppm
0.01ppm/0.1ppm
0.01ppm/0.1ppm
0.01ppm/0.1ppm
0.01ppm/0.1ppm
0.01ppm/0.1ppm
1ppm/0.01%VOL
≤10S
≤10S
≤10S
≤10S
≤10S
≤10S
≤10S
≤10S
≤10S
≤10S
≤10S
≤10S
4

Application
Petrochemical & Chemcial Industry Municipal Engineering & Utilities Agricultral & Environmental Protection
Electronic Food & Pharmaceutical Industry Other Industries
GD400
used in sewers and
underground areas
GD400
applied in confined spaces like
warehouse, ships, factories,ect.
GD400
applied in Oil & Gas industries like
Shell or Petros
GD400
used in coal mines
Project Cases
5

More Application
Furniture, Floor, Wallpaper, Coating, Gardening, Interior Decoration and Renovation, Dyestuff, Papermaking,
Pharmacy, Health Care, Foodstuff, Antiseptic.
Disinfection, Chemical Fertilizer, Resin, Adhesive, Pesticide, Raw Material, Sample, Technological Process, Livestock
Farm, Refuse Processing Plant, Perm Place.
Bio-pharmaceutical Plant, Green Household, Livestock Breeding, Green House Cultivating, Warehouse Logistics,
Brewing And Fermentation, Agricultural Production.
6

ACCURATE • RAPID • RELIABLE
GD400 Series Gas
Detector User Manual
7

PLEASE READ CAREFULLY BEFORE USING
Anyone who may use, maintain or repair the instrument should read this operating manual
carefully and only follow the operating manual to achieve the design level. Otherwise the
instrument will not work properly and will cause malfunction and damage to the instrument.
Warning:
▲ The readings beyond the range indicate the concentration of the gas that may or will soon
reach the explosion concentration or the concentration of casualties.
▲ Replacing components can affect the intrinsic safety of the instrument.
▲ It is strictly forbidden to charge the meter in a hazardous area. Users must use the
special charger equipped with this unit.
▲ Do not disassemble, recharge or replace batteries in hazardous locations. ▲ Charging
must be turned off; the instrument must not be operated while charging or exporting data.
▲ Portable products, before entering the danger zone, doing electrostatic release of human body,
and then carries the instrument into the zone.
▲ Do not use the computer's USB interface for communication in hazardous areas. ▲ Old and
new batteries or batteries from different manufacturers cannot be mixed.
Attentions :
To ensure maximum safety and performance, please read and follow the items and conditions
listed below.
● The air intake of the sensor must be kept clean. Blocking the sensor's air intake
may result in readings that are lower than the actual gas concentration .
It is strictly forbidden to use compressed air to clean the air inlet of the sensor to avoid
damage to the sensor.
● Catalytic Principle Flammable Gas Sensor and Infrared Principle Sensor can only
accurately monitor designated gases. It should be noted, however, that the catalytic principle
flammable sensor is not specific to a particular gas and will be able to react to other flammable
gases.
● If the instrument is subject to physical impact or high pollution, the calibration
cycle needs to be shortened.
● The sensitivity of flammable gas sensors will be affected by high concentrations
of sulfides, halogen compounds, silicon-containing compounds, and gases containing "mercury"
and "lead", steam, and high temperature organic acid gases. Avoid using them in environments
containing the above chemicals. The instrument, if necessary, must be tested and calibrated after
use to avoid affecting the accuracy of the instrument.
● The instrument is strictly prohibited from being used in a high concentration of
flammable gas for a long time to avoid damage to the flammable sensor. If it is necessary, the
instrument should be tested and calibrated after use to avoid affecting the accuracy of the
instrument. If the flammable sensor is damaged, it needs to be replaced with a new one. The
new sensor can only be reused after it has been calibrated.
8

●Do not use organic solvents, soap or silicon-containing solutions to clean the
instrument to avoid damaging the sensor.
● When sampling with a sampling tube, do not use a sampling tube made of
silicone material or other sampling tubes that are not certified by the special source.
● A sudden change in air pressure or a blocked air circuit may cause temporary
fluctuations in the instrument's oxygen readings.
● Large changes in pressure will result in incorrect readings. If the measured gas
pressure is greater than 10% of the atmospheric pressure, it will affect the instrument reading
and even damage the sensor. The instrument should be re-calibrated and the measured gas
should be depressurized.
● It is forbidden to artificially use the gas shock sensor that exceeds the range of
the instrument. If the over-range high-concentration gas impact occurs, the
instrument must be re-calibrated.
● When replacing any one of the sensors, the instrument needs to be calibrated.
● Standard gas should be selected from the manufacturer or the nationally
qualified enterprise.
● The calibration should be in a well ventilated environment to avoid
contamination.
●It is strictly forbidden to calibrate the instrument under the condition of
insuffcient power supply.
● Do not use the instrument in an oxygen-rich environment.
● It is strictly forbidden to replace the components or structures that affect the
explosion-proof performance at will, so as not to affect the explosion-proof
performance.
● It is forbidden to expose the instrument to high concentration acid and alkali gas
to avoid damage to the sensor.
● It is strictly forbidden for users to repair or replace parts without authorization.
● A sudden change in temperature can cause the output signal of the infrared
sensor to be abnormal. After the transient is removed, the instrument will resume normal
operation and the ambient temperature change rate should be limited to 2 ° C / min.
●If the gas sample flow rate changes excessively, it will also cause the infrared sensor
output signal to be abnormal. After the transients are removed, the instrument will
resume normal operation and the gas flow rate should be kept below 0.6 L/min.
It is strictly forbidden to expose the infrared sensor to corrosive gas such as hydrogen sulfide.
It is strictly forbidden to cause condensation inside the sensor.
Condensation phenomenon inside sensor is strictly prohibited.
●
●
9

Calibration Warning:
●Gas detection equipment is a safe life-saving measuring instrument. To ensure
metering accuracy, toxic and catalytic principles flammable gas sensors should be
calibrated at least once every six months, while infrared sensors should be calibrated once
a year.
●The gas detector needs to be carefully tested or calibrated after an alarm
occurs.
●This instrument has the function of recording and querying the calibration date.
Please check it frequently. Not only do users need to understand the parameters of the
instrument, but they also need to understand the meaning of the test data obtained.
10

2, Product series and models
3, Product characteristic
4, Product description
5, Product configuration
6, Technical specifications
7, Battery charge
8, Operation procedures
9, Power on/off
9.1 Power on
9.2 Power off
10, User interface
10.1 Detection interface
10.2 Status IndicatorIcon
11, Operation overview
11.1 Alarm function checking
11.2 Information checking
11.3 Menu
12, Function
12.1 Fresh air/zero calibration
12.2 Span calibration
12.3 CaIibration interval
13, Alarm setting
13.1 Alarm Iimit
13.2 Alarm mode
13.3 Alarm latched
13.4 Man down alarm
13.4.1 Turn on/off man down alarm
13.4.2 Motion less Time
13.4.3 Sensitivity
13.4.4 Warning time
13.5 Comfort beep
13.5.1 On/off
13.5.2 Time
14, Datalog
14.1 Storage on/off
14.2 Storage interval
14.3 Data type
14.4 Data view
14.5 Data disk
14.6 Full option
14.7 Clear record
15, Monitor set
15.1 Pump on/off
15.2 Unit
15.3 Date and time set
Contents
1, Overview ------------------------------------------------------------------------ 7
------------------------------------------------------ 7
----------------------------------------------------------- 7
-------------------------------------------------------------- 7
----------------------------------------------------------- 8
--------------------------------------------------------- 8
------------------------------------------------------------------- 9
---------------------------------------------------------- 10
------------------------------------------------------------------- 11
------------------------------------------------------------------- 11
------------------------------------------------------------------- 12
----------------------------------------------------------------- 13
-------------------------------------------------------- 13
------------------------------------------------------- 13
----------------------------------------------------------- 14
--------------------------------------------------- 14
------------------------------------------------------ 14
---------------------------------------------------------------------- 15
---------------------------------------------------------------------- 15
------------------------------------------------- 15
----------------------------------------------------------- 16
------------------------------------------------------- 18
------------------------------------------------------------------ 18
----------------------------------------------------------------- 18
--------------------------------------------------------------- 19
------------------------------------------------------------- 20
---------------------------------------------------------- 21
------------------------------------------- 21
------------------------------------------------------- 21
------------------------------------------------------------- 21
---------------------------------------------------------- 21
-------------------------------------------------------------- 22
------------------------------------------------------------------ 22
------------------------------------------------------------------- 22
----------------------------------------------------------------------- 22
------------------------------------------------------------- 22
----------------------------------------------------------- 23
------------------------------------------------------------------- 23
------------------------------------------------------------------ 23
------------------------------------------------------------------ 24
----------------------------------------------------------------- 25
--------------------------------------------------------------- 25
------------------------------------------------------------------- 25
--------------------------------------------------------------- 25
---------------------------------------------------------------------- 26
---------------------------------------------------------- 26
11

15.4 Language
15.5 Display set
15.5.1 Brightness
15.5.2 Auto brightness
15.5.3 Screen rotation
15.5.4 Sleep mode set
15.6 Security and Privacy
15.6.1 Modify Password
15.6.2 Site ID and User ID
15.7 Self-test
15.8 Reset
15.8.1 Reset Sensor
15.8.2 Reset device
15.9 Bluetooth
16, About
16.1 Monitor Information
16.2 Sensor information
16.3 Calibration record
17, Common faults and solutions
18, Terms of Service
18.1 Warranty Commitment
18.2 Fault repair time
18.3 Limited liability guarantee
19, Technical support and manufacturer
------------------------------------------------------------------ 26
----------------------------------------------------------------- 26
------------------------------------------------------------- 26
------------------------------------------------------- 27
------------------------------------------------------- 27
------------------------------------------------------- 27
------------------------------------------------------ 28
----------------------------------------------------- 28
----------------------------------------------------- 28
----------------------------------------------------------------- 28
------------------------------------------------------------------ 29
---------------------------------------------------------- 29
---------------------------------------------------------- 29
---------------------------------------------------------------- 29
-------------------------------------------------------------------- 30
------------------------------------------------------- 30
------------------------------------------------------- 30
--------------------------------------------------------- 30
------------------------------------------------ 31
-------------------------------------------------------------- 32
----------------------------------------------------- 32
----------------------------------------------------------- 32
------------------------------------------------ 32
------------------------------------------ 33
12

1、Overview
GD400(volatile organic compounds , combustible gas and toxic gas) at the same time and
has man down alarm function. The device has humanized operation functions such as one-
key security detection, one-key storage, automatic image flipping, as well as the man down
alarm function. With optional Bluetooth transmission function, allowing safety personnel to
obtain real-time data and the alarm status, it has obtained international IECEX, ATEX
explosion-proof certification and Chinese explosion-proof certification; As it passed the
antistatic test, and the protection level reaches IP67; With safer product design and the
module design which makes the detection faster, and the compact ergonomic design makes
the device easy carrying.
The explosion-proof grade of the GD400 series is Ex d ia IIC T4 Ga, which is applicable to
the explosive gas mixture zone 0, zone 1, and zone 2 of the factory with grades IIA, IIB, and
ITC and temperature group T1~T4.
2、Product series and models The
SKY3000 series includes:
1.GD400(regular 4-in-1)
2. GD400-M (single gas)
3. GD400-M2 (two composite gases)
3. GD400-M3 {three composite gases)
4. GD400-M4 (unconventional 4-in-1 gas)
3、 Product characteristic
Rugged and durable
The instrument can effectively resist a three-meter drop.
The protection level of the instrument reaches IP67.
The instrument has passed the EMC anti-static interference test and can work normally
in
the walkie-talkie environment.
Explosion-proof circuit design, safe and reliable
The instrument has got IECEx, ATEX, Chinese explosion-proof certificates and
the explosion-proof level reaches Ex d ia IIC T4 Ga
Multiple security protection
The man down alarm function has upgraded the safety of underground operators.
Password protection function prevents non-operators from modifying menu parameters.
With safety reminder function, sound and light vibration alarm function, let operators work
without worries.
The high and low alarm latched function allows the operator to better capture the sudden
change of the gas concentration value.
Simultaneous measurement of multiple gases, multiple numerical display
The instrument can detect 1-5 gases at the same time.
Real-time value, TWA, STEL, MAX, MIN multiple numerical display.
Large screen display, flexible detection system, multiple filtering devices
The screen can be automatically turned 180 degrees, which is convenient for viewing
in special operating environments.
Built-in powerful sampling pump, fast detection speed.
Can be connected 20m sampling tube externally, which is convenient for long-distance or
13

confined space detection.
With a water trap filter, it can effectively filter water, oil, dust and other impurities. It can also
be used in harsh industrial environments , such as coal mines and petroleum fields.
Powerful function, more user-friendly operation
Beautiful and friendly user interface, reasonable and easy-to-use interactive mode.
Optional Bluetooth function, data can be transmitted to the mobile phone or PC in real
time.
Standard storage function, one-click data export, convenient for users to analyze.
Unique modifiable ID identification function, convenient for users to allocate and
manage the instrument.
A full range of automatic detection functions, automatic prompts for voltage, pump
failure alarms, etc., more comfortable to use One-key security detection, one-key open
storage, automatic image flip.
Support PPM and mg/m3 gas unit switch, the concentration value is automatically
converted by the system.
Support each channel sensor to restore the factory setting separately.
Support multi-Language including English , Chinese and etc.
4、Product description
(top view)
(left view) (front view) (right view) (back view)
(buttom view)
①Y+key ⑥Gas outlet
②Mode key ⑦Gas inlet
③N-key ⑧Belt clip
④Buzzer ⑨Charging and communication contact
⑤Display ⑩Alarm light
14

Sampling method pump suction type
Response time CO、O2、EX<30 seconds,H2S<60 seconds
Language Chinese/English (more language can be custormized)
Automatically test
and calibrate after
power-on
Including reset,maximum value (MAX), minimum value (MIN), STEL, TWA
value
Unit μmol/mol、mg/m³、PPM can be swifted
①[Y/+] key, Long press to turn on or off the datalog function (main interface);
confirm entry/switch (menu interface); Numerical increase (need to enter the numerical interface);
stop ( calibration countdown interface).
②[MODE] key, Long press to power On/off (any interface): Exit (menu interface)
Confirm (need to enter the numerical interface).
③[N/-] key, Long press to enter the main menu (the display interface enters the
menu interface); move down or right options (menu interface).
④Buzzer: Voice prompt and alarm function.
⑤Display, Display gas concentration and various parameters.
⑥Sensor, Measure gas concentration.
⑦Filter, Gas inlet.
⑧Belt clip, Stainless steel material, auxiliary fixing entrainment instrument.
⑨Charging and communication contact: Connect the charging stand to charge the
instrument / transmit data to the PC.
⑩LED light, Light alarm function.
5、 Product configuration
1, Standard accessories :
(1) Gas detector 1 piece
(2) 12V/1A DC power adapter 1 piece
(3) Charge base 1 piece
(4) USB cable 1 piece
(5) User manual 1 piece
(6) warranty card 1 piece
(7) Filter 1 piece
(8) Aluminum suitcase 1 Piece
(9)1 rubber stopper (please install the rubber stopper in time after charging/data
transfer is completed.)
6、 Product specifications
15

Display monochrome graphics (160x96) ,screen can be automatically flipped
Backlight The backlight time can be manually set, and will be turned on
automatically when an alarm is issued
Data record Can store 100,000 sets data, the storage interval is adjustable from 5 to 3600
seconds, data can be exported, with data cable
Alarm
95dB buzzer (@30cm), vibration alarm and flashing red LED and alarm status
indication on the screen, alarm latched; diagnostic alarm and battery
undervoltage alarm, pump block alarm; man down alarm, with early warning
and optional real-time remote Bluetooth
Battery 3.7V rechargeable lithium battery
Working hours More than 15 hours in continuous pumping mode
Charger Travel charger with DC interface, charging time = 4 hours
Explosion-proof grade IECEx:Ex da ia IIC T4 Ga(with EX sensor),Ex ia IIC T4 Ga(without EX sensor)
ATEX: II 1G Ex da ia IIC T4 Ga, II 1G Ex ia IIC T4 Ga
Certification
(EU Regulation) 2014/34/EU(ATEX)
Protection grade IP67
Working temperature -20°C~+50°C
Humidity 0~90%RH (no condensation)
Environmental pressure 86~106Kpa
Size 157*84.5*59.5mm (including back clip/water trap filter) (length• width
• height)
Weight 365g(including battery, belt clip and filter)
7、Battery charging
The detector is equipped with special charging equipment, and the charging process is
shown in the figure below.
Charging
stand Indicator
light
USB
interface
Power
interface
16

1、First, insert the charging/ communication contact into the charging stand to ensure that
the detector is tightly engaged with the charger stand
2、Then insert the round plug of the power adapter into the jack on one side of the charger
stand, and plug the other end of the power adapter into the power source.
3、The detector is charged after connecting with power source, the LED indicator is red, and
the display shows the charging status. After the battery is fully charged, the display shows that
the battery is fully charged which means the charging is complete.
Note
1. It is forbidden to charge the detector in non-safe areas.
2. Please do not violently plug or unplug the detector and charging equipment.
3. Before charging, check whether there is dirt on the contacts and probes,
whether the contacts on the back of the detector are in good contact with the probes of the
charging stand, and whether the bite is in place.
8、Operation process
Shutdown
No
3 Seconds? Yes Power On Self-test Monitor
Password Check No
Succeed?Yes
Menu
Calibrate Alarm Datalog Monitor About
Fresh air/Zero calib
Span calibrate
Calibration interval
Alarm limit
Alarm mode
Alarm latch Man
down alarm
Confort beep
High alarm value
Low alarm value
STEL alarm value
TWA alarm value
Datalog On/Off
Interval
Data type Data
view Data disk
Full option Clear
record
Pump on/off Unit
Date&time
Language
Display
Security&privac
y Self-test
Reset Bluetooth
Brightness
Auto brightness
Screen rotate
Sleep mode
Reset sensor
Reset device
Monitor info
Calibrate record
Sensor info
17

9、Power on/off
9.1 Power on
When the detector is off, press and hold the [MODE] key, the backlight will light up,
and a countdown progress bar will appear on the screen. Release the [MODE] key after the
countdown complete. Then the detector starts, the backlight,alarm light and vibration turn on.
SAFEGAS mark will appear on the screen, and then enter the self-check interface.
CO
PPMPPM
%L E L
H2S
EX
0
0.00
Ch ec k
%VOL
O2
20.9
2s e c
Power on...
Device info
Version:
Site ID:
User ID:
Factory:
V1.2.7
0001
0001
2021-05-20
Sensor info
PPM
%V OL % L EL
100
100
1000
30.0
PPM
O2
CO H 2S
EX
High alarm value
CO
200
H2S
PPMPPM
%VOL %L E L
O2EX
50
20.0
23.5
Low alarm value
CO
PPMPPM
%VOL %L E L
H2S
O2EX
20
10.0
19.5
100
STEL alarm value
CO
PPMPPM
H2S
6.030
TWA alarm value
CO
PPMPPM
H2S
3.020
Storage info
Used: 0.04MB
Usable:14.94MB
59
Sensor is warming up
Calibrate info
Last
The next calib is 180days
Self-test
202 1 - 0 5- 2 0
Serial number
SN : 0 120 1 C 17B 0 0 1
Self-testSelf-test
Self-testSelf-test Self-testSelf-test
Self-test Self-test
18

PPM PPM PPM PPM
The normal start up of the detector will gradually display the following steps, showing the
current settings of the instrument:
1. Equipment information: version, site ID, user ID, manufacture date
2. Serial no
3. Sensor information
4. High alarm value
5. Low alarm value
6. STEL
7. TWA
8. Data log information
9. Calibration information
After loading the self-test interface, it will enter the sensor preheating interface, and there will
also be a countdown action. This action takes about 1-2 minutes. After the countdown, the
display interface will prompt whether the detector is performing fresh air/zero calibration.
During the calibration, a 10-second countdown will be displayed, and the calibration
can also be terminated during the process. Once the calibration is completed, it will
formally enter the detection interface and the detector is successfully turned on.
Note:Please keep the battery fully charged and start the machine in a fresh air environment.
If you can't start the machine to eliminate the above problems, please contact sales for
consultation.
9.2 Power Off
Press and hold [MODE] . A 5-second countdown to shutoff begins. You must hold your
finger on the key for the entire shutoff process until the device is powered off.
19

PPM PPM
Icon function
Bluetooth function(This is an optional function, shown when bluetooth is on,blank when off) Pump
on status
Pump off status
Storage function ( Shown when storage is on, blank when off)
Power ( three segments show battery charge level)
In the Shutdown state, long press [N/-] key for 3 seconds to briefly display the following
device information
1. Gas type
2. Measure range
3. Power
4. User ID
5. Site ID
Note: Please turn off the device after the reading drops to zero in clean air (except for
oxygen,nitrogen and carbon dioxide)
10、User Interface
10.1 Detection interface
The LCD display provides visual feedback that includes the sensor types, readings,
battery condition, and other functions.
Real-time status
of calibration and
functional test
Sensor type
Air pump
Datalog
Battery status
indicator
Reading
Unit of measure
Soft keys(functions
change by activity)
Wireless Bluetooth
Man down alarm
Ch e c k
10.2 Status Indicator Icon
CO
PPM
0
1 gas
CO H2S
0.0
PPMPPM
%V O L
O2
0
Check
20.93
3 gas
CO
PPM
PPM
HIGH
Ch eck
H2S
O2
EX
SO2
0
0.0
20.9
0
0
%VOL
%LEL
PPM
5 gas2 gas
CO
PPM
PPM
H2S
0.0
0
Ch e c k
20
This manual suits for next models
5
Table of contents
Other GasDog Gas Detector manuals