Cazoner CZR-HD1002 User manual

Point for Attention
Donotinstallitintheplacethattooclosetothegasstove!
Donotinstallitintheplacewithtoomuchsmoke!
Donotinstallitintheplaceofexhaustfan,doors,
windows,bathroomsandotherlargeairfloworhumiditylarger!
Key Function Operation Guide
Self-testKey:Detectingthesoundandlightalarmtoseeifitis
abnormal.
Noalarmstate-->Presstheself-testbutton-->Thedisplayshows
8.8%whilethegreenlight,yellowlightandredlightareon
sequentially
-->buzzersounding-->100secondswarm-upcountdownstarts
Iftheringindicatorlightorbuzzerisabnormal,pleaserepairit
intime.
Two installation methods (A/B):
A: (Paste 3M tape)
1)Cleanthewallinasuitableposition
2)Stickthe3Mtapeonthedetachablebackplateofthealarm,
thenputthearrowupandperpendicularlytothegroundto
pressitonthewallfor10seconds.
3)Installthealarmonthedetachablebackplateandrotateitto
therighttolock
B: (Screw mounting)
1)Drillingtwosuitableholesonthewall,andthentightenthe
detachablebackplateontheholes
2)Installthealarmonthedetachablebackplateandrotateitto
therighttolock
Installation Location
Thedetectorandthegasstoveshouldbelocatedinthesame
indoorspace.
Thebestdistancebetweenthedetectorandthegasleaksourceis
1-3meters.
Naturalgasiscomprisedofmethanegasthatislighterthanair.
Incaseofgasleakage;gasrisestowardsceilingandaccumulates
inareasnearceiling.Therefore,fornaturalgas,thedetectorshall
belocatedinapositionof0.3mundertheceilingand(1-3)
metersawayfromgassupply.
LPGiscomprisedofmixtureofpropaneandbutanethatis
heavierthanair.Incaseofgasleakage,LPGfallsdownto
ground.Therefore,forLPG,thedetectorshallbelocatedina
positionof0.3mabovethefloorand(1-3)metersawayfrom
gassupply.
2
Contact
InstallationInstructions
3
CAZONERNaturalGasDetectorManual
USB1
USB2(Backup)
LCDdisplay
DetechableBackPlate
Self-testbutton
PowerIndicator
ProductIntroduction
CAZONER natural gas detector is a household detection
equipment for detecting the leakage of natural gas and
liquefied petroleum gas.Whenthe gas leaks reach to the
concentrationofdangerousvalueinthehouse,thesignalofthe
detector'saudibleandvisualalarmwillbeissuedimmediately
thatpromotingyoutotakeeffectiveactionquicklytoeliminate
the danger so that can avoid the accidents like fire and
explosioneffectively.
Sensor
Madewithoriginalcores
Thegas-sensingelectrodesmaterialis
100%pureplatinumpreciousmetal.
Alarmmode
Thesoundlevelalarmis85dB.Withtheincreaseofgas
concentration,theacousto-opticfrequencygradually
increase.
1
Website:http://www.cazoner.com/
Tel:8615811801081
Email:[email protected]
Address:A1564FNiulanqianBuildingLonghuanew
District
Shenzhen,China.
Zipcode:518101
THANKYOUFORREADING:)
Concentration value of working state(0-20%LEL):
GreenBreathing:0%-2%Greenlight"breathing",nocombustible
gasdetected(Normal)
YellowFlashing:2%-5%Yellowflashing,slightcombustiblegas
detected(Needtobevigilant)
Redflashing:5%-20%Redflashingquickly+Buzzerquick
alarm,highconcentrationcombustiblegasdetected(Dangerous)
YellowFlashing+Buzzeralarmsynchronously:Faultstatus
CZR-HD1002
Detect Natural Gas
(Methane)
Detect LP Gas
(Propane)
Installation Guide:
If the gas is natural gas,install the detector at the
distance of 0.3m from the ceiling and 1-3m from
the gas source.
If the gas is LPG,install it at the distance of 0.3m
from the floor and 1-3m from the gas source.
Floor
Ceiling
0.3m
0.3m
1-3m

CZR-HD1002
Natural Gas /LPG
70g
Semiconductor
70mm * 70mm * 28mm
Natural diffusion
DC5V±0.1V
0-20% LEL
100s
5%LEL
Visible and Audible alarm
Temperature: -20 to 40
Humidity: ≤ 95% RH (no frost)
85dB
5 years
Model
Applicable Gas
Weight
Overall Dimensions
Sampling Method
Working Voltage
Range
Self-test Time
Alarm presetting
level
Alarm
Working
Environment
Alarm Volume
Lifespan
Sensor Type
56
Failure
Phenomenon
The connection
of the power cord
is not well
Power indicator
has failed
Press the self-test
button without
sound and
light alarm
Circuit failure
No response
to detection
of gas
Pre-boot program
has not over yet
Circuit failure
After the
pre-start
procedure,
the detector has
been in the
alarm state
There are large
amount of volatile
organic compounds
surround
Place the
detector
in a clean
air environment
andrestart the
self-test
program
Long storage
Circuit failure
Please check
thepower cord
connection and
connect it again
Please contact
the seller for
assistance
Please contact
the seller for
assistance
Wait for the
program to
complete the
pre-boot
Please contact
the seller for
assistance
Please contact
the seller for
assistance
Continue to
aging it with
electricity
The green power
indicator does
not light
7
MainSpecifications Commonfaultsandsolutions
FailureAnalysis Solutions
After-sales service and Warranty Policy
4EquipmentMaintenance
1.First time to use: Please aging it with electricity for more than 24
hours when first to be used after a long-distance transport or long
storagesothatitcankeepthebestperformance.
2.Self-checking period: Please self-test it for every 4-6 months.When
youuseanknownconcentrationofgastotestthedetectortoconfirm
whether it will work, please be sure the operation environment is
absolutelysafe!
3.Cleaning:Pleaseusesoftbrush,velvetcleaningtoolstocleanitsface
end's dust or oil to ensure its detection hole breathable so that can
keep good display.Please do not use detergents, bleach or other
cleaningliquidtocleanit.
4.Indooruse only:Please avoidrain ormoisture whenuse it.Please
avoiditfalldown.Donotbeat,openorchangeit,oritmightcausesthe
productfailure.
6.Lifespan:Themaximumlifeofthedetectoris5yearsundernormal
situation.Pleasereplaceanewonewhenovertheuseoftheperiod.
5.Avoid volatile substances surround: Please do not use volatile
substanceslikealcoholorhairgelneartothedetector.Ifthiskindof
material causes the false report of the detector, please ventilates
promptlysothatitcanreturntothenormalexaminationcondition.
SUPPORT ONE-YEAR FREE REPLACEMENT,BUT CAN NOT ENJOY
THE WARRANTY UNDER THE SITUATION OF NON-NORMAL USE
(FOR EXAMPLE: LIGHTNING, VOLTAGE INSTABILITY, WATER AND
OTHER HUMAN FACTORS)
Other Cazoner Gas Detector manuals
Popular Gas Detector manuals by other brands

MSA
MSA Altair operating manual

NTI
NTI E-H2 Installation and operation manual

Kathrein
Kathrein FCM 100 user manual

Henan Oceanus Import & Export
Henan Oceanus Import & Export OC-F08 operating manual

System Sensor
System Sensor CO1224T Frequently asked questions

Agilent Technologies
Agilent Technologies 423B Operating and service manual

Bacharach
Bacharach MGS-350 Installation and operation manual

BW Technologies
BW Technologies GasAlertMicro 5 Quick reference guide

TLV
TLV SonicMan SO2 instruction manual

Macurco
Macurco TX-6-AM User instructions

SANJIANG
SANJIANG JTQ-BM-925TE instruction manual

HENAN HANWEI ELECTRONICS
HENAN HANWEI ELECTRONICS BX616 using manual