WARNING RISK OF FIRE
7RUHGXFHWKHULVNRIVHYHUHLQMXU\RUGHDWKIROORZDOOLQVWDOODWLRQLQVWUXFWLRQV
&ORWKHVGU\HULQVWDOODWLRQPXVWEHSHUIRUPHGE\DTXDOL¿HGLQVWDOOHU
,QVWDOOWKHFORWKHVGU\HUDFFRUGLQJWRWKHVHLQVWUXFWLRQVDQGLQDFFRUGDQFHZLWKORFDO
FRGHV
California Safe Drinking Water and Toxic Enforcement Act
7KLVDFWUHTXLUHVWKHJRYHUQRURI&DOLIRUQLDWRSXEOLVKDOLVWRIVXEVWDQFHVNQRZQWRWKH
VWDWHWRFDXVHFDQFHUELUWKGHIHFWVRURWKHUUHSURGXFWLYHKDUPDQGUHTXLUHVEXVLQHVVHV
WR ZDUQ FXVWRPHUV RI SRWHQWLDO H[SRVXUH WR VXFK VXEVWDQFHV *DV DSSOLDQFHV FDQ
FDXVHPLQRUH[SRVXUHWRIRXURIWKHVHVXEVWDQFHVQDPHO\EHQ]HQHFDUERQPRQR[LGH
IRUPDOGHK\GHDQGVRRWFDXVHGSULPDULO\E\WKHLQFRPSOHWHFRPEXVWLRQRIQDWXUDOJDV
RU/3IXHOV3URSHUO\DGMXVWHGGU\HUVZLOOPLQLPL]HLQFRPSOHWHFRPEXVWLRQ([SRVXUHWR
WKHVHVXEVWDQFHVFDQEHPLQLPL]HGIXUWKHUE\SURSHUO\YHQWLQJWKHGU\HUWRWKHRXWGRRUV
7KLVGU\HUPXVWEHH[KDXVWHGWRWKHRXWGRRUV
8VH RQO\ ULJLG PHWDO µ GLDPHWHU GXFWZRUN LQVLGH WKH GU\HU FDELQHW DQG XVH RQO\ 8/
DSSURYHGWUDQVLWLRQGXFWLQJEHWZHHQWKHGU\HUDQGWKHKRPHGXFW
'2127LQVWDOODFORWKHVGU\HUZLWKÀH[LEOHSODVWLFGXFWLQJPDWHULDOV,IÀH[LEOHPHWDO
VHPLULJLGRUIRLOW\SHGXFWLVLQVWDOOHGLWPXVWEH8/OLVWHGDQGLQVWDOOHGLQDFFRUGDQFH
ZLWKWKHLQVWUXFWLRQVIRXQGLQ´&RQQHFWLQJ7KH'U\HU7R+RXVH9HQWµRQSDJHRIWKLV
PDQXDO)OH[LEOHYHQWLQJPDWHULDOVDUHNQRZQWRFROODSVHEHHDVLO\FUXVKHGDQGWUDS
OLQW7KHVHFRQGLWLRQVZLOOREVWUXFWGU\HUDLUÀRZDQGLQFUHDVHWKHULVNRI¿UH
'RQRWLQVWDOORUVWRUHWKLVDSSOLDQFHLQDQ\ORFDWLRQZKHUHLWFRXOGEHH[SRVHGWRZDWHU
DQGRUZHDWKHU
6DYHWKHVHLQVWUXFWLRQV,QVWDOOHUV%HVXUHWROHDYHWKHVHLQVWUXFWLRQVZLWKWKH
FXVWRPHU
IN THE COMMONWEALTH OF MASSACHUSETTS
TKLV SURGXFW PXVW EH LQVWDOOHG E\ DOLFHQVHG SOXPEHU RU JDV ¿WWHU
WKHQ XVLQJ EDOOW\SH JDV VKXWRII YDOYHV WKH\ VKDOO EH WKH TKDQGOH W\SH
A IOH[LEOH JDV FRQQHFWRU ZKHQ XVHG PRVW QRW H[FHHG IHHW
IQVWDOODWLRQ
IQVWUXFWLRQV
GDV 'U\HU
08
4XHVWLRQV RQ IQVWDOODWLRQ" CDOO 800GECARES USRU 800 CDQDGD
RUYLVLWRXUZHEVLWHDWwww.GEAppliances.com (US)
BEFORE YOU BEGIN
RHDG WKHVH LQVWUXFWLRQV
FRPSOHWHO\ DQG FDUHIXOO\
IM3ORTANT6DYH
WKHVHLQVWUXFWLRQVIRUORFDO
LQVSHFWRU·VXVH
IM3ORTANT2EVHUYH
DOOJRYHUQLQJFRGHVDQG
RUGLQDQFHV
NRWH WR IQVWDOOHU %HVXUHWR
OHDYHWKHVHLQVWUXFWLRQVZLWK
WKHFXVWRPHU
NRWH WR CXVWRPHU .HHSWKHVH
LQVWUXFWLRQVZLWK\RXU2ZQHU·V
0DQXDOIRUIXWXUHUHIHUHQFH
%HIRUHWKHROGGU\HULVUHPRYHG
IURPVHUYLFHRUGLVFDUGHG
UHPRYHWKHGU\HUGRRU
,QVSHFWWKHGU\HUH[KDXVW
RXWOHWDQGVWUDLJKWHQWKH
RXWOHWZDOOVLIWKH\DUHEHQW
6HUYLFHLQIRUPDWLRQDQGWKH
ZLULQJGLDJUDPDUHORFDWHGLQ
WKHFRQWUROFRQVROH
'RQRWDOORZFKLOGUHQRQ
RULQWKHDSSOLDQFH&ORVH
VXSHUYLVLRQRIFKLOGUHQLV
QHFHVVDU\ZKHQWKHDSSOLDQFH
LVXVHGQHDUFKLOGUHQ
,QVWDOOWKHGU\HUZKHUHWKH
WHPSHUDWXUHLVDERYH)IRU
VDWLVIDFWRU\RSHUDWLRQRIWKH
GU\HUFRQWUROV\VWHP
3URGXFWIDLOXUHGXHWR
LPSURSHULQVWDOODWLRQLVQRW
FRYHUHGXQGHUWKH:DUUDQW\
234D1582P008 31-16679 03-12 GE
6WHS 9HULI\\RXUJDVLQVWDOODWLRQVHHVHFWLRQ
6WHS 3UHSDUHWKHDUHDDQGH[KDXVWIRULQVWDOODWLRQRIQHZGU\HU
VHHVHFWLRQ
6WHS &KHFNDQGHQVXUHWKHH[LVWLQJH[WHUQDOH[KDXVWLVFOHDQVHH
VHFWLRQDQGPHHWVDWWDFKHGLQVWDOODWLRQVSHFL¿FDWLRQVVHH
VHFWLRQ
6WHS 5HPRYHWKHIRDPVKLSSLQJSDGVVHHVHFWLRQ
6WHS 0RYHWKHGU\HUWRWKHGHVLUHGORFDWLRQ
6WHS /HYHO\RXUGU\HUVHHVHFWLRQ
6WHS &RQQHFWWKHJDVVXSSO\VHHVHFWLRQDQGFKHFNIRUOHDNV
VHHVHFWLRQ
6WHS &RQQHFWWKHH[WHUQDOH[KDXVWVHHVHFWLRQ
6WHS &RQQHFWWKHSRZHUVXSSO\VHHVHFWLRQ
6WHS
&KHFNWKHRSHUDWLRQRIWKHSRZHUVXSSO\JDVFRQQHFWLRQV
DQGYHQWLQJ
6WHS
3ODFHWKH2ZQHU·V0DQXDODQGWKH,QVWDOODWLRQ,QVWUXFWLRQVLQ
DORFDWLRQZKHUHWKH\ZLOOEHQRWLFHGE\WKHRZQHU
)RUDOFRYHRUFORVHWLQVWDOODWLRQVHHVHFWLRQ
)RUEDWKURRPRUEHGURRPLQVWDOODWLRQVHHVHFWLRQ
)RUPRELOHRUPDQXIDFWXUHGKRPHVHHVHFWLRQ
)RUJDUDJHLQVWDOODWLRQLIDOORZHGE\ORFDOFRGHVVHHVHFWLRQ
)RUVLGHRUERWWRPH[KDXVWVHHVHFWLRQ
LEVEL
8
"
PIPE WRENCH
10" ADJUSTABLE WRENCHES
(x2)
TOOLS YOU WILL NEED
SLIP JOINT PLIERS
FLAT BLADE SCREWDRIVER
MATERIALS YOU WILL NEED
GLOVES
SAFETY
GLASSES
4" DUCT
CLAMPS (2)
OR
4" SPRING
CLAMPS (2)
EXHAUST
HOOD
4" DIA. METAL
ELBOW
4" DIA. FLEXIBLE METAL (SEMI-RIGID)
UL LISTED TRANSITION DUCT
(IF NEEDED)
KIT WX08X10077 (INCLUDES 2 ELBOWS)
4" DIA. METAL DUCT
(RECOMMENDED)
4" DIA. FLEXIBLE METAL (FOIL TYPE)
UL LISTED TRANSITION DUCT
(IF NEEDED.)
DUCT TAPE
SOAP SOLUTION
FOR LEAK DETECTION
PIPE
COMPOUND
FLEXIBLE GAS LINE CONNECTOR

IQVWDOODWLRQ IQVWUXFWLRQV
MLQLPXP COHDUDQFH OWKHU TKDQ AOFRYH RU CORVHW IQVWDOODWLRQ
0LQLPXPFOHDUDQFHWRFRPEXVWLEOHVXUIDFHVDQGIRUDLURSHQLQJDUHLQFOHDUDQFHERWKVLGHVDQGLQUHDU&RQVLGHUDWLRQ
PXVWEHJLYHQWRSURYLGHDGHTXDWHFOHDUDQFHIRULQVWDOODWLRQDQGVHUYLFH
PREPARING FOR INSTALLATION
OF NEW 'RYER
TIPIQVWDOO \RXU GU\HU EHIRUH LQVWDOOLQJ \RXU ZDVKHU
TKLV ZLOO DOORZ EHWWHU DFFHVV ZKHQ LQVWDOOLQJ GU\HU H[KDXVW
'ISCONNECTING GAS
WARNING NE9ER REUSE OL'
FLE;IBLE CONNECTORS
7KHXVHRIROGÀH[LEOHFRQQHFWRUVFDQFDXVHOHDNV
DQGSHUVRQDOLQMXU\$OZD\VXVHQHZÀH[LEOH
FRQQHFWRUVZKHQLQVWDOOLQJJDVDSSOLDQFHV
REMO9ING LINT FROM WALL E;HAUST
OPENING
5HPRYHDQGGLVFDUGH[LVWLQJSODVWLFRUPHWDOIRLOWUDQVLWLRQ
GXFWDQGUHSODFHZLWK8/OLVWHGWUDQVLWLRQGXFW
INTERNAL DUCT
OPENING CHECK THAT EXHAUST
HOOD DAMPER OPENS
AND CLOSES FREELY.
WALL
TILT THE DRYER SIDEWAYS
AND REMOVE THE FOAM
SHIPPING PADS BY
PULLING AT THE SIDES
AND BREAKING THEM
AWAY FROM THE DRYER
LEGS. BE SURE TO
REMOVE ALL OF THE
FOAM PIECES AROUND
THE LEGS.
TURN GAS
SHUT-OFF
VALVE TO THE
OFF POSITION.
DISCONNECT AND DISCARD OLD
FLEXIBLE GAS CONNECTOR AND
OLD DUCTING MATERIAL.
REPLACE WITH NEW CSA(AGA)
APPROVED FLEXIBLE GAS LINE
CONNECTOR AND UL APPROVED
TRANSITION DUCT.
2GAS REQUIREMENTS
WARNING
,QVWDOODWLRQPXVWFRQIRUPWRORFDOFRGHVDQG
RUGLQDQFHVRULQWKHLUDEVHQFHWKH1$7,21$/)8(/*$6
&2'($16,=
7KLVJDVGU\HULVHTXLSSHGZLWKD9DOYH%XUQHU
$VVHPEO\IRUXVHRQO\ZLWKQDWXUDOJDV8VLQJFRQYHUVLRQ
NLW:(;\RXUORFDOVHUYLFHRUJDQL]DWLRQFDQ
FRQYHUWWKLVGU\HUIRUXVHZLWKSURSDQH/3JDV$//
&219(56,2160867%(0$'(%<3523(5/<75$,1('
$1'48$/,),('3(56211(/$1',1$&&25'$1&(:,7+
/2&$/&2'(6$1'25',1$1&(5(48,5(0(176
7KHGU\HUPXVWEHGLVFRQQHFWHGIURPWKHJDVVXSSO\
SLSLQJV\VWHPGXULQJDQ\SUHVVXUHWHVWLQJRIWKDWV\V
WHPDWDWHVWSUHVVXUHLQH[FHVVRI36,.3D
7KHGU\HUPXVWEHLVRODWHGIURPWKHJDVVXSSO\SLSLQJ
V\VWHPE\FORVLQJWKHHTXLSPHQWVKXWRȺYDOYHGXULQJ
DQ\SUHVVXUHWHVWLQJRIWKHJDVVXSSO\SLSLQJRIWHVW
SUHVVXUHHTXDOWRRUOHVVWKDQ36,.3D
'RYER GAS SUPPLY CONNECTION
$LQ1DWLRQDO3LSH7DSHUWKUHDGSOXJJHGWDSSLQJ
DFFHVVLEOHIRUWHVWJDXJHFRQQHFWLRQPXVWEHLQVWDOOHG
LPPHGLDWHO\XSVWUHDPRIWKHJDVVXSSO\FRQQHFWLRQWR
WKHGU\HU&RQWDFW\RXUORFDOJDVXWLOLW\VKRXOG\RXKDYH
TXHVWLRQVRQWKHLQVWDOODWLRQRIWKHSOXJJHGWDSSLQJ
6XSSO\OLQHLVWREHLQULJLGSLSHDQGHTXLSSHGZLWK
DQDFFHVVLEOHVKXWRȺZLWKLQIWRIDQGLQWKHVDPH
URRPZLWKWKHGU\HU
8VHSLSHWKUHDGVHDOHUFRPSRXQGDSSURSULDWHIRUQDWX
UDORU/3JDVRUXVH7HÀRQWDSH
<RXPXVWXVHZLWKWKLVGU\HUDÀH[LEOHPHWDOFRQQHFWRU
OLVWHGFRQQHFWRU$16,=&6$7KHOHQJWKRI
WKHFRQQHFWVKDOOQRWH[FHHGIW
&RQQHFWÀH[LEOHPHWDOFRQQHFWRUWRGU\HUDQGJDVVXSSO\
2SHQVKXWRȺYDOYH
*DVFORWKHVGU\HUVLQSXWUDWLQJVDUHEDVHGRQVHDOHYHO
RSHUDWLRQDQGQHHGQRWEHDGMXVWHGIRURSHUDWLRQDWRU
EHORZIWHOHYDWLRQ
)RURSHUDWLRQDWHOHYDWLRQVDERYHIWLQSXWUDWLQJV
VKRXOGEHUHGXFHGDWDUDWHRISHUFHQWIRUHDFKIW
DERYHVHDOHYHO
,QVWDOODWLRQPXVWFRQIRUPWRORFDOFRGHVDQGRUGLQDQFHVRU
LQWKHLUDEVHQFHWKH1$7,21$/)8(/*$6&2'($16,=
A'-USTING FOR ELE9ATION
2"
2-5/8" 3/8" NPT MALE THREAD GAS SUPPLY
NOTE: Add to vertical dimension
the distance between cabinet
bottom to floor.

IQVWDOODWLRQ IQVWUXFWLRQV
RECONNECTING GAS
NEW METAL
FLEXIBLE GAS
LINE CONNECTOR
ADAPTER
ELBOW
ITEMS NOT SUPPLIED
ADAPTER
SHUT-OFF
VALVE
PIPE SIZE
AT LEAST 1/2"
1/8" NPT PIPE
PLUG FOR
CHECKING GAS
INLET PRESSURE
3/8" NPT
Listed connector ANSI Z21.24 / CSA 6.10
FLARE NPT
127(7KHFRQQHFWRUDQG¿WWLQJVDUHGHVLJQHGIRUXVH
RQO\RQWKHRULJLQDOLQVWDOODWLRQDQGDUHQRWWREHUHXVHG
IRUDQRWKHUDSSOLDQFHRUDWDQRWKHUORFDWLRQ.HHSÀDUH
HQGRIDGDSWRUIUHHRIJUHDVHRLODQGWKUHDGVHDODQW
CAUTION8VHDGDSWRUVDVVKRZQ&RQQHFWRU
QXWVPXVWQRWEHFRQQHFWHGGLUHFWO\WRSLSHWKUHDGV
APPLY PIPE COMPOUND
TO THE ADAPTER AND
DRYER GAS INLET.
Tighten the flexible
gas line using two
adjustable wrenches.
APPLY PIPE COMPOUND
TO ALL MALE THREADS.
7LJKWHQDOOFRQQHFWLRQVXVLQJWZRDGMXVWDEOH
ZUHQFKHV 'R QRW RYHUWRUTXH JDV FRQQHFWLRQV
&KHFNDOOFRQQHFWLRQVIRUOHDNVZLWKVRDS\VROXWLRQRU
HTXLYDOHQW$SSO\VRDSVROXWLRQLHDN WHVW VROXWLRQ PXVW
QRW FRQWDLQ DPPRQLD ZKLFK FRXOG FDXVH GDPDJH WR WKH
EUDVV ¿WWLQJV ,IOHDNVDUHIRXQGFORVHYDOYHUHWLJKWHQWKH
MRLQWDQGUHSHDWWKHVRDSWHVW
LEAK TEST
WARNING NE9ER USE AN OPEN
FLAME TO TEST FOR GAS LEAKS
OPEN
GAS VALVE.

EXHAUST INFORMATION
EXHAUST SYSTEM CHECK LIST
HOO'OR WALL CAP
7HUPLQDWHLQDPDQQHUWRSUHYHQWEDFNGUDIWVRUHQWU\RI
ELUGVRURWKHUZLOGOLIH
7HUPLQDWLRQVKRXOGSUHVHQWPLQLPDOUHVLVWDQFHWR
WKHH[KDXVWDLUÀRZDQGVKRXOGUHTXLUHOLWWOHRUQR
PDLQWHQDQFHWRSUHYHQWFORJJLQJ
1HYHULQVWDOODVFUHHQLQRURYHUWKHH[KDXVWGXFW7KLV
FRXOGFDXVHOLQWEXLOGXS
:DOOFDSVPXVWEHLQVWDOOHGDWOHDVWLQDERYHJURXQG
OHYHORUDQ\RWKHUREVWUXFWLRQZLWKWKHRSHQLQJSRLQWHG
GRZQ
SEPARATION OF TURNS
)RUEHVWSHUIRUPDQFHVHSDUDWHDOOWXUQVE\DWOHDVWIW
RIVWUDLJKWGXFWLQFOXGLQJGLVWDQFHEHWZHHQODVWWXUQDQG
H[KDXVWKRRG
TURNS OTHER THAN 90º
2QHWXUQRIRUOHVVPD\EHLJQRUHG
7ZRWXUQVVKRXOGEHWUHDWHGDVRQHWXUQ
(DFKWXUQRYHUVKRXOGEHWUHDWHGDVRQHWXUQ
4" DIA.
4"
4" DIA.
4" DIA.
2-1/2"
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
No. of 90°
Elbows Rigid
Metal Rigid
Metal
150 Feet
135 Feet
125 Feet
115 Feet
105 Feet
125 Feet
115 Feet
105 Feet
95 Feet
85 Feet
0
1
2
3
4
Use only for short
run installations
EXHAUST LENGTH
595 Feet 75 Feet
IQVWDOODWLRQ IQVWUXFWLRQV
WARNING IN CANA'A AN'IN THE
UNITE'STATESTHE REQUIRE'EXHAUST
'UCT 'IAMETER IS LQ 02PP 'O NOT
USE 'UCT LONGER THAN SPECIFIE'IN THE
EXHAUST LENGTH TABLE
8VLQJH[KDXVWORQJHUWKDQVSHFL¿HGOHQJWKZLOO
,QFUHDVHWKHGU\LQJWLPHVDQGWKHHQHUJ\FRVW
5HGXFHWKHGU\HUOLIH
$FFXPXODWHOLQWFUHDWLQJDSRWHQWLDO¿UHKD]DUG
TKH FRUUHFW H[KDXVW LQVWDOODWLRQ LV YOUR
RESPONSIBILITYPUREOHPV GXH WR LQFRUUHFW
LQVWDOODWLRQ DUH QRW FRYHUHG E\ WKH ZDUUDQW\
5HPRYHDQGGLVFDUGH[LVWLQJSODVWLFRUPHWDOIRLO
WUDQVLWLRQGXFWDQGUHSODFHZLWK8/OLVWHGWUDQVLWLRQGXFW
7KHMAXIMUM ALLOWABLEGXFWOHQJWKDQGQXPEHURI
EHQGVRIWKHH[KDXVWV\VWHPGHSHQGVXSRQWKHW\SHRI
GXFWQXPEHURIWXUQVWKHW\SHRIH[KDXVWKRRGZDOO
FDSDQGDOOFRQGLWLRQVQRWHGEHORZ7KHPD[LPXPGXFW
OHQJWKIRUULJLGPHWDOGXFWLVVKRZQLQWKHWDEOHEHORZ
ELECTRICAL CONNECTION INFORMATION
WARNING TO RE'UCE THE
RISK OF FIREELECTRICAL SHOCKAN'
PERSONAL IN-URY
'O NOT USE AN EXTENSION COR'
OR AN A'APTER PLUG WITH THIS
APPLIANCE
'U\HUPXVWEHHOHFWULFDOO\JURXQGHGLQDFFRUGDQFH
ZLWKORFDOFRGHVDQGRUGLQDQFHVRULQWKHDEVHQFH
RIORFDOFRGHVLQDFFRUGDQFHZLWKWKH1$7,21$/
(/(&75,&$/&2'($16,1)3$12
ELECTRICAL REQUIREMENTS
TKLV DSSOLDQFH PXVW EH VXSSOLHG ZLWK 209 0H] DQG
FRQQHFWHG WR DSURSHUO\ JURXQGHG EUDQFK FLUFXLW SUR
WHFWHG E\ D RU 20DPS FLUFXLW EUHDNHU RU WLPH GHOD\
IXVH IIHOHFWULFDO VXSSO\ SURYLGHG GRHV QRW PHHW WKH
DERYH VSHFL¿FDWLRQV LW LV UHFRPPHQGHG WKDW DOLFHQVHG
HOHFWULFLDQ LQVWDOO DQ DSSURYHG RXWOHW
WARNING THIS 'RYER IS
EQUIPPE'WITH A THREEPRONG
GROUN'INGPLUG FOR YOUR
PROTECTION AGAINST SHOCK HA=AR'
AN'SHOUL'BE PLUGGE''IRECTLY
INTO A PROPERLY GROUN'E'THREE
PRONG RECEPTACLE'O NOT CUT OR
REMO9E THE GROUN'ING PRONG
FROM THIS PLUG
IF LOCAL CODES PERMIT,
AN EXTERNAL GROUND WIRE
(NOT PROVIDED), WHICH MEETS
LOCAL CODES, MAY BE ADDED
BY ATTACHING TO THE GREEN
GROUND SCREW ON THE REAR
OF THE DRYER, AND TO A GROUNDED
METAL COLD WATER PIPE OR OTHER
ESTABLISHED GROUND.
ENSURE PROPER GROUN'EXISTS BEFORE USE

IQVWDOODWLRQ IQVWUXFWLRQV
SEALING OF -OINTS
$OOMRLQWVVKRXOGEHWLJKWWRDYRLGOHDNV7KHPDOHHQGRI
HDFKVHFWLRQRIGXFWPXVWSRLQWDZD\IURPWKHGU\HU
7KHGXFWVKDOOQRWEHDVVHPEOHGZLWKVFUHZVRURWKHU
IDVWHQLQJPHDQVWKDWH[WHQGLQWRWKHGXFWDQGFDWFKOLQW
'XFWMRLQWVFDQEHPDGHDLUDQGPRLVWXUHWLJKWE\
ZUDSSLQJWKHRYHUODSSHGMRLQWVZLWKGXFWWDSH
+RUL]RQWDOUXQVVKRXOGVORSHGRZQWRZDUGWKHRXWGRRUV
LQFKSHUIRRW
INSULATION
'XFWZRUNWKDWUXQVWKURXJKDQXQKHDWHGDUHDRULV
QHDUDLUFRQGLWLRQLQJVKRXOGEHLQVXODWHGWRUHGXFH
FRQGHQVDWLRQDQGOLQWEXLOGXS
7EXHAUST CONNECTION
BEFORE PERFORMING THIS EXHAUST
INSTALLATIONBE SURE TO 'ISCONNECT THE
'RYER FROM ITS ELECTRICAL SUPPLY
WARNING TO RE'UCE THE RISK
OF FIRE OR PERSONAL IN-URY
7KLVFORWKHVGU\HUPXVWEHH[KDXVWHGWRWKHRXWGRRUV
8VHRQO\µ ULJLGPHWDO GXFWLQJIRU WKHKRPH H[KDXVW
GXFW
8VHRQO\µULJLGPHWDORU8/OLVWHGÀH[LEOHPHWDOVHPL
ULJLGRUIRLOW\SHGXFWWRFRQQHFWWKHGU\HUWRWKHKRPH
H[KDXVWGXFW,W PXVWEH LQVWDOOHGLQ DFFRUGDQFHZLWK
WKH LQVWUXFWLRQV IRXQG LQ ´&RQQHFWLQJ WKH 'U\HU WR
+RXVH9HQWµRQSDJHVRIWKLVPDQXDO
'RQRWWHUPLQDWHH[KDXVWLQDFKLPQH\DZDOODFHLOLQJ
JDV YHQW FUDZO VSDFH DWWLF XQGHU DQ HQFORVHG ÀRRU
RU LQ DQ\ RWKHU FRQFHDOHG VSDFH RI D EXLOGLQJ 7KH
DFFXPXODWHGOLQWFRXOGFUHDWHDSRWHQWLDO¿UHKD]DUG
1HYHUWHUPLQDWHWKHH[KDXVWLQWRDFRPPRQGXFWZLWK
DNLWFKHQH[KDXVWV\VWHP$FRPELQDWLRQRIJUHDVHDQG
OLQWFUHDWHVDSRWHQWLDO¿UHKD]DUG
'R QRW XVH GXFW ORQJHU WKDQ VSHFL¿HG LQ WKH H[KDXVW
OHQJWKWDEOH/RQJHUGXFWVFDQDFFXPXODWHOLQWFUHDWLQJ
DSRWHQWLDO¿UHKD]DUG
1HYHULQVWDOODVFUHHQLQRURYHUWKHH[KDXVWGXFW7KLV
ZLOOFDXVHOLQWWRDFFXPXODWH FUHDWLQJD SRWHQWLDO¿UH
KD]DUG
'R QRW DVVHPEOH GXFWZRUN ZLWK DQ\ IDVWHQHUV WKDW
H[WHQGLQWRWKHGXFW7KHVHIDVWHQHUVFDQDFFXPXODWH
OLQWFUHDWLQJDSRWHQWLDO¿UHKD]DUG
'RQRWREVWUXFWLQFRPLQJRUH[KDXVWHGDLU
3URYLGH DQ DFFHVV IRU LQVSHFWLRQ DQG FOHDQLQJ RI WKH
H[KDXVW V\VWHP HVSHFLDOO\ DW WXUQV DQG MRLQWV ([KDXVW
V\VWHPVKDOOEHLQVSHFWHGDQGFOHDQHGDWOHDVWRQFHD\HDU.
CONNECTING THE 'RYER TO HOUSE 9ENT
RIGI'METAL TRANSITION 'UCT
)RUEHVWGU\LQJSHUIRUPDQFHDULJLGPHWDOWUDQVLWLRQGXFW
LVUHFRPPHQGHG
5LJLGPHWDOWUDQVLWLRQGXFWVUHGXFHWKHULVNRIFUXVKLQJDQG
NLQNLQJ
GAS
INLET
PIPE
EXTERNAL
DUCT
OPENING
DUCT TAPE OR
DUCT CLAMP
DUCT TAPE OR
DUCT CLAMP
(CUT TO PROPER
LENGTH)
4" METAL DUCT
CSA (AGA) APPROVED
NEW FLEXIBLE GAS
LINE CONNECTOR
NOTE: WE STRONGLY RECOMMEND SOLID METAL EXHAUST DUCTING.
HOWEVER, IF FLEXIBLE DUCTING IS USED IT MUST BE UL-LISTED METAL
NOT PLASTIC.
FOR STRAIGHT LINE INSTALLATION, CONNECT THE DRYER EXHAUST TO
THE EXTERNAL EXHAUST HOOD USING DUCT TAPE OR CLAMP.
STAN'AR'REAR EXHAUST
9HQWHG DW ÀRRU OHYHO
STAN'AR'REAR EXHAUST
9HQWHG DERYH ÀRRU OHYHO
NOTEELBOWS WILL PRE9ENT 'UCT KINKING AN'
COLLAPSING
RECOMMENDED
CONFIGURATION
TO MINIMIZE
EXHAUST
BLOCKAGE.
ELBOW HIGHLY
RECOMMENDED
ELBOW HIGHLY
RECOMMENDED
THIS 'RYER COMES REA'Y FOR REAR
EXHAUSTINGIF SPACE IS LIMITE'
USE THE INSTRUCTIONS IN STEP TO
EXHAUST 'IRECTLY FROM THE SI'E OR
BOTTOM OF THE CABINET

IQVWDOODWLRQ IQVWUXFWLRQV
LE9ELING 'RYER
9ALCO9E OR CLOSET INSTALLATION
,I\RXUGU\HULVDSSURYHGIRULQVWDOODWLRQLQDQ DOFRYHRU
FORVHWLWZLOOEHVWDWHGRQDODEHORQWKHGU\HUEDFN
7KH GU\HU MUST EH YHQWHG WR WKH RXWGRRUV 6HH WKH
EXHAUST INFORMATIONVWHS
0LQLPXPFOHDUDQFHEHWZHHQGU\HUFDELQHWDQGDGMDFHQW
ZDOOVRURWKHUVXUIDFHVLV
LQHLWKHUVLGH
LQIURQW
LQUHDU
0LQLPXPYHUWLFDOVSDFHIURPÀRRUWRRYHUKHDGFDELQHWV
FHLOLQJHWFLVLQ
&ORVHW GRRUV PXVW EH ORXYHUHG RU RWKHUZLVH YHQWLODWHG
DQGPXVWFRQWDLQDPLQLPXPRIVTLQRIRSHQDUHD
HTXDOO\GLVWULEXWHG,IWKHFORVHWFRQWDLQVERWKDZDVKHU
DQGDGU\HUGRRUVPXVWFRQWDLQDPLQLPXPRIVTLQ
RIRSHQDUHDHTXDOO\GLVWULEXWHG
7KHFORVHWVKRXOGEH YHQWHGWR WKHRXWGRRUV WRSUHYHQW
JDVSRFNHWLQJLQFDVHRIDJDVOHDNLQWKHVXSSO\OLQH
1RRWKHUIXHOEXUQLQJDSSOLDQFHVKDOOEHLQVWDOOHGLQWKH
VDPHFORVHWZLWKWKHGU\HU
ELBOWS HIGHLY
RECOMMENDED
ELBOW HIGHLY
RECOMMENDED
DO
DO NOT
SIT DRYER
ON FLEXIBLE
EXHAUST
DO NOT USE
EXCESSIVE
EXHAUST
LENGTH
DO NOT
CRUSH
FLEXIBLE
EXHAUST
AGAINST
W ALL.
DON’T
8
LEVEL
SIDE-TO-SIDE.
4 LEVELING LEGS
2 ANTI-TIP LEGS
LEVEL
FRONT-TO-BACK.
STAND THE DRYER UPRIGHT NEAR THE
FINAL LOCATION AND ADJUST THE 4 LEVELING
LEGS TO MATCH THE HEIGHT OF YOUR WASHER.
ADJUST THE 2 ANTI-TIP LEGS TO CONTACT
THE FLOOR.
ULLISTE'FLEXIBLE METAL SEMIRIGI' TRANSITION 'UCT
,IULJLGPHWDOGXFWFDQQRWEHXVHGWKHQ8/OLVWHGÀH[LEOH
PHWDOVHPLULJLGGXFWLQJFDQEHXVHG.LW:;;
1HYHULQVWDOOÀH[LEOHPHWDOGXFWLQZDOOVFHLOLQJVÀRRUVRU
RWKHUHQFORVHGVSDFHV
7RWDOOHQJWKRIÀH[LEOHPHWDOGXFWVKRXOGQRWH[FHHGIHHWP
)RUPDQ\DSSOLFDWLRQVLQVWDOOLQJHOERZVDWERWKWKHGU\HU
DQG WKH ZDOO LV KLJKO\ UHFRPPHQGHG VHH LOOXVWUDWLRQV
EHORZ (OERZV DOORZ WKH GU\HU WR VLW FORVH WR WKH ZDOO
ZLWKRXW NLQNLQJ DQG RU FUXVKLQJ WKH WUDQVLWLRQ GXFW
PD[LPL]LQJGU\LQJSHUIRUPDQFH
$YRLGUHVWLQJWKHGXFWRQVKDUSREMHFWV
ULLISTE'FLEXIBLE METAL FOILTYPETRANSITION 'UCT
,
Q VSHFLDO LQVWDOODWLRQV LW PD\ EH QHFHVVDU\ WR FRQQHFW WKH
GU\HUWRWKHKRXVHYHQWXVLQJDÀH[LEOHPHWDOIRLOW\SHGXFW
$ 8/OLVWHG ÀH[LEOH PHWDO IRLOW\SH GXFW PD\ EH XVHG 21/<
LQLQVWDOODWLRQV ZKHUHULJLGPHWDO RUÀH[LEOH PHWDOVHPLULJLG
GXFWLQJ FDQQRW EH XVHG $1' ZKHUH D µ GLDPHWHU FDQ EH
PDLQWDLQHGWKURXJKRXWWKHHQWLUHOHQJWKRIWKHWUDQVLWLRQGXFW
,Q &DQDGD DQG WKH 8QLWHG 6WDWHV RQO\ WKH ÀH[LEOH PHWDO
IRLOW\SH GXFWV WKDW FRPSO\ ZLWK WKH ´2XWOLQH IRU &ORWKHV
'U\HU7UDQVLWLRQ'XFW6XEMHFW$µVKDOOEHXVHG
1HYHULQVWDOOÀH[LEOHPHWDOGXFWLQZDOOVFHLOLQJVÀRRUVRU
RWKHUHQFORVHGVSDFHV
7RWDOOHQJWKRIÀH[LEOHPHWDOGXFWVKRXOGQRWH[FHHGIHHWP
$YRLGUHVWLQJWKHGXFWRQVKDUSREMHFWV
)RUEHVWGU\LQJSHUIRUPDQFH
6OLGHRQHHQGRIWKHGXFWRYHUWKHFORWKHVGU\HURXWOHWSLSH
6HFXUHWKHGXFWZLWKDFODPS
:LWKWKHGU\HULQLWVSHUPDQHQWSRVLWLRQH[WHQGWKHGXFW
WRLWVIXOOOHQJWK$OORZµRIGXFWWRRYHUODSWKHH[KDXVWSLSH
&XWRȺDQGUHPRYHH[FHVVGXFW.HHSWKHGXFWDVVWUDLJKW
DVSRVVLEOHIRUPD[LPXPDLUÀRZ
6HFXUHWKHGXFWWRWKHH[KDXVWSLSHZLWKWKHRWKHUFODPS
0
BATHROOM OR BE'ROOM INSTALLATION
7KHGU\HU0867EHYHQWHGWRWKHRXWGRRUV6HH(;+$867
,1)250$7,21VWHS
7KHLQVWDOODWLRQPXVWFRQIRUPZLWKORFDOFRGHVRULQWKH
DEVHQFH RI ORFDO FRGHV ZLWK WKH 1$7,21$/ )8(/ *$6
&2'($16,=

Through the rear opening, locate the tab in the middle of
the appliance base. Lift the tab to about 45º using a flat
blade screwdriver.
BEND TAB
UP 45 o
'RYER EXHAUST TO BOTTOM CABINET
WARNING BEFORE PERFORMING
THIS EXHAUST INSTALLATIONBE SURE
TO 'ISCONNECT THE 'RYER FROM ITS
ELECTRICAL SUPPLYPROTECT YOUR
HAN'S AN'ARMS FROM SHARP E'GES
WHEN WORKING INSI'E THE CABINET
BE SURE TO WEAR GLO9ES
IQVWDOODWLRQ IQVWUXFWLRQV
REMOVE
SCREW
AND SAVE.
REMOVE BOTTOM
KNOCKOUT
BOTTOM
EXHAUST
PORTION "A"
FIXING
HOLE
MOBILE OR MANUFACTURE'HOME
INSTALLATION
,QVWDOODWLRQ PXVW FRQIRUP WR WKH 0$18)$&785(' +20(
&216758&7,216$)(7<67$1'$5'7,7/(3$57
RUZKHQVXFKVWDQGDUGLVQRWDSSOLFDEOHZLWK$0(5,&$1
1$7,21$/67$1'$5')2502%,/(+20($16,1)3$12
%
7KH GU\HU 0867 EH YHQWHG WR WKH RXWGRRUV ZLWK WKH
WHUPLQDWLRQ VHFXUHO\ IDVWHQHG WR WKH PRELOH KRPH
VWUXFWXUH6HH(;+$867,1)250$7,21VHFWLRQ
7KH YHQW 0867 127 EH WHUPLQDWHG EHQHDWK D PRELOH RU
PDQXIDFWXUHGKRPH
7KHYHQWGXFWPDWHULDO0867%(0(7$/
.,7'0867EHXVHGWRDWWDFKWKHGU\HUVHFXUHO\
WRWKHVWUXFWXUH
7KHYHQW0867127EHFRQQHFWHGWRDQ\RWKHUGXFWYHQW
RUFKLPQH\
'RQRWXVHVKHHWPHWDOVFUHZVRURWKHUIDVWHQLQJGHYLFHV
ZKLFKH[WHQGLQWRWKHLQWHULRURIWKHH[KDXVWYHQW
3URYLGHDQRSHQLQJZLWKDIUHHDUHDRIDWOHDVWVTLQIRU
LQWURGXFWLRQRIRXWVLGHDLULQWRWKHGU\HUURRP
6WDFNLQJRIDJDVGU\HULVQRWSHUPLWWHGLQDPRELOHKRPH
RUPDQXIDFWXUHGKRPH
TAB LOCATION
A''ING NEW 'UCT
'HWDFK DQG UHPRYH WKH ERWWRP NQRFNRXW 5HPRYH WKH
VFUHZLQVLGHWKHGU\HUH[KDXVWGXFWDQGVDYH3XOOWKHGXFW
RXWRIWKHGU\HU3URWHFWVKDUSHGJHVDURXQGWKHNQRFNRXW
DQGH[KDXVWRSHQLQJZLWKWKHWDSH
Cut the duct as shown and keep portion A.
9"
AB
FIXING HOLE
5HFRQQHFWWKHFXWSRUWLRQ$RIWKHGXFWWRWKHEORZHU
KRXVLQJ0DNHVXUHWKDWWKH¿[LQJKROHLVDOLJQHGZLWKWKH
WDELQWKHEDVH8VHWKHVFUHZVDYHGSUHYLRXVO\WRVHFXUH
WKHGXFWLQSODFHWKURXJKWKHWDERQWKHDSSOLDQFHEDVH
A''ING ELBOW FOR EXHAUST
THROUGH BOTTOM OF CABINET
,QVHUWµHOERZWKURXJKWKHERWWRPRSHQLQJRULHQWLWIRU
ERWWRPH[KDXVWDQGFRQQHFWLWWRWKHGU\HULQWHUQDOGXFW
GARAGE INSTALLATION IF ALLOWE'
BY LOCAL CO'ES
'U\HUV LQVWDOOHG LQ JDUDJHV PXVW EH HOHYDWHG LQFKHV
FPDERYHWKHÀRRU
2
CAUTION,QWHUQDOGXFW
MRLQWVPXVWEHVHFXUHGZLWKWDSH
RWKHUZLVHWKH\PD\VHSDUDWHDQG
FDXVHDVDIHW\KD]DUG
$SSO\GXFWWDSHRQWKHMRLQWEHWZHHQWKHGU\HULQWHUQDO
GXFWDQGHOERZ
DUCT
TAPE

IQVWDOODWLRQ IQVWUXFWLRQV
A''ING 'UCT FOR EXHAUST THROUGH
BOTTOM OF CABINET
,QVHUWWKHµVWUDLJKWGXFWLQWKHHOERZHQGKDQJLQJRXW
RIWKHGU\HUERWWRP:UDSGXFWWDSHDURXQGWKHMRLQW
CAUTIONBHVXUH QRW WR SXOO RU GDPDJH WKH
HOHFWULFDO ZLUHV LQVLGH WKH GU\HU ZKHQ LQVHUWLQJ WKH GXFW
A''ING CO9ER PLATE TO REAR OF
CABINET
&RQQHFWVWDQGDUGPHWDOHOERZVDQGGXFWVWRFRPSOHWH
WKHH[KDXVWV\VWHP&RYHUEDFNRSHQLQJZLWKDSODWH.LW
:(0DYDLODEOHIURP\RXUORFDOVHUYLFHSURYLGHU3ODFH
GU\HULQ¿QDOORFDWLRQ
WARNINGNE9ER LEA9E THE
BACK OPENING WITHOUT THE PLATE
KIT WEM
CHANGING 'IRECTION OF 'OOR
OPENING
REMOVE 4
HINGE SCREWS.
REMOVE 4 HOLE PLUGS AND
PLACE THEM IN THE HOLES
ON THE OPPOSITE SIDE.
ROTATE DOOR 180
AND REINSTALL.
°
5(*,67(5<2851(:$33/,$1&(725(&(,9($1<
,03257$17352'8&7127,),&$7,216
3OHDVHJRWR www.GEAppliances.comRUPDLOLQ
\RXUSURGXFWUHJLVWUDWLRQFDUG
)RUTXHVWLRQVRQLQVWDOODWLRQFDOO86RU
&DQDGD
SER9ICING
WARNINGLABEL ALL WIRES
PRIOR TO 'ISCONNECTING WHEN
SER9ICING CONTROLSWIRING
ERRORS CAN CAUSE IMPROPER AN'
'ANGEROUS OPERATION AFTER
SER9ICINGINSTALLATION
PL ATE
(KIT WE1M454)
Table of contents
Other GE Dryer manuals
Popular Dryer manuals by other brands

SUPREME
SUPREME JET DRY EXECUTIVE II quick start guide

AGUZZO
AGUZZO Dual Wired Ezy-Fit installation instructions

Siemens
Siemens WT43H07LDN User manual and installation instructions

Inglis
Inglis IJ8200 Use & care guide

Whirlpool
Whirlpool LG5801XK0 Use & care guide

John Lewis
John Lewis JLTDC 09 instruction manual