Gedore Dremotest E 8612-012 User manual

www.gedore.com
11/2016
Operating Instructions
Dremotest E
8612-012 . 8612-050
8612-300 . 8612-1000
8612-3150
CN

Electronic Torque Tester DREMOTEST E
Probador de torque eléctrico DREMOTEST E
Contrôleur de couple électronique DREMOTEST E
Elektronisches Prüfgerät DREMOTEST E
Elektronisch testapparaat DREMOTEST E
Strumento elettronico di prova DREMOTEST E
Elektroniczny przyrząd kontrolny DREMOTEST E
Aparelho electrónico de ensaio DREMOTEST E
Электронный контрольный прибор
DREMOTEST E
Elektronik test cihazı DREMOTEST E
电子检测仪 DREMOTEST E
www.gedore.com

Operating Instructions
(Translation of the German Operating Instructions)
AVOID INJURY.You MUST read and understand these
Operating Instructions before using the product! 4 - 22
Instrucciones de manejo
(Traducción de las instrucciones de manejo)
EVITE LESIONES. Usted DEBE leer y entender estas
instrucciones de manjeo antes de usar el el producto! 23 - 42
Instructions d‘emploi (Traduction des instructions d‘emploi)
POUR EVITER LES BLESSURES, vous DEVEZ lire et comprendre
les instructions d‘emploi avant d´utiliser le produit! 43 - 62
Betriebsanleitung (Original-Betriebsanleitung)
VERMEIDEN SIE VERLETZUNGEN. Sie MÜSSEN diese
Betriebsanleitung lesen und verstehen, bevor Sie das
Produkt benutzen. 63 - 82
Gebruiksaanwijzing (Vertaling van de gebruiksaanwijzing)
VOORKOM LETSEL. U MOET deze handleiding lezen en
begrijpen alvorens het product in gebruik te nemen. 83 - 102
Istruzioni per l´uso (Traduzione delle istruzioni per l´uso)
EVITARE LESIONI. Leggere e comprendere ASSOLUTAMENTE
le presenti istruzioni per l´uso prima di utilizzare il prodotto. 103 - 121
Instrukcji eksploatacji (Tłumaczenie instrukcji eksploatacji)
Przed rozpoczęciem korzystania z produktu NALEŻY
bezwzględnie przeczytaćinstrukcji eksploatacji. 122 - 141
Instruções de funcionamento
(Tradução das instruções de funcionamento)
EVITE FERIMENTOS. DEVE ler e compreender estas
instruções de funcionamento, antes de utilizar o produto! 142 - 161
Руководство по эксплуатации
(Перевод руководства по эксплуатации)
ИЗБЕГАЙТЕ ТРАВМ. Перед использованием изделия
НЕОБХОДИМО прочитать ипонять это
руководство по эксплуатации. 162 - 182
İşletme kılavuzu (İşletme kılavuzunun tercümesidir)
YARALANMALARDAN KAÇININ. Ürünü kullanmadan önce
bu kullanma kılavuzunu okuyup anlamanız ZORUNLUDUR. 183 - 201
装配说明书 (译自德文原版装配说明书)
为避免损伤,您必须在使用扭矩扳手前仔
细阅读和理解使用说明书 202 - 218
CN

4
EN
Table of Contents
1. Important Safety Information 5
1.1 Safety Warnings 5
OVERLOAD HAZARD 6
INACCURATE TORQUE SETTINGS 6
EXPLOSION AND FIRE HAZARD 6
TEMPERATURE CONDITIONS 7
RISK OF ELECTROCUTION 7
1.2 Personal Protective Gear 7
1.3 Intended Use 8
1.4 Handling 8
1.5 Work Environment 9
2. Product Description 10
2.1 Scope of Delivery 11
3. Using the Torque Tester 11
3.1 Terms Used 12
3.2 Mounting the Torque Tester 12
3.3 Activating / Deactivating 13
3.3.1 Activating 14
3.3.2 Deactivating 14
3.4 Taring the Torque Tester 14
3.5 Switching the Units of Measurement 15
3.6 RS232 Interface and Connection to a Computer 15
3.7 Testing a Torque Wrench with the Torque Tester 16
3.8 Electronic overload notification 19
4. Maintenance 19
4.1 Testing and Calibrating 19
4.2 Care and Storage 21
5. Accessories and Parts 21
6. Environmentally Friendly Disposal 21
7. Manufacturer 21
8. Technical Data 22

5
EN
1. Important Safety Information
Read and understand these Operating Instructions before
using the torque tester. SERIOUS INJURY or DEATH can
result from incorrect use.
These Operating Instructions are part of the torque tester.
They must be kept in a safe place for later use and be passed
along with the torque tester if it is sold, loaned, or otherwise
transferred.
The torque tester should only be used by TRAINED
PERSONNEL who have been taught how to safely use and
handle the torque tester. Using the torque tester without
training may result in SERIOUS INJURY or DEATH.
Employers purchasing this torque tester MUST ensure
employees using the torque tester have read and understood
the Operating Instructions prior to using the torque tester. The
Operating Instructions MUST be available to the employees
for reference at all times.
1.1 Safety Warnings
Throughout this operating manual WARNING, CAUTION,
NOTICE and the safety alert symbol will be used.
WARNING Indicates a hazardous situation that,
if not avoided, could result in death or
serious injury.
CAUTION Indicates a hazardous situation that,
if not avoided, could result in minor or
moderate injury.
NOTICE.
Addresses practices not related to
personal injury, but are related to
property damage or in damage to the
torque wrench.
This is the safety alert symbol. It is
used to alert you to potential personal
injury hazards. Obey all safety
messages that follow this symbol to
avoid possible injury or death.

6
EN
WARNING
OVERLOAD HAZARD
The torque tester can be overloaded during use and break
causing SERIOUS INJURY or DEATH.
ALWAYS use only original accessory parts. Accessory parts
not approved by Gedore may not bear the loads or cause the
torque tester to overload.
ALWAYS inspect the torque tester for damage BEFORE use.
NEVER use a damaged torque tester.
NEVER use the torque tester if it has been dropped, if it has
been used to strike other objects, or if anything has fallen on
it.
WARNING
INACCURATE TORQUE SETTINGS
An out-of-calibration torque tester can result in the failure of
the screw connections, the torque wrench, or the accessories.
This could cause SERIOUS INJURY or DEATH.
An out-of-calibration torque tester may cause the torque
wrench settings to be over- or under- torque, resulting in
SERIOUS INJURY or DEATH.
ALWAYS use tested and calibrated torque testers ONLY
(see Section 4.1 Testing and Calibrating).
WARNING
EXPLOSION AND FIRE HAZARD
Sparks can occur when using the torque tester, which can
cause an explosion or a fire and could cause SERIOUS
INJURY or DEATH.
NEVER use the torque wrench in areas where sparks can
cause explosions or fires.

7
EN
WARNING
TEMPERATURE CONDITIONS
When the torque tester is exposed to temperatures less than
64°F (18°C) or above 82°F (28°C) or high levels of humidity
(above 90%), it may cause inaccurate torque settings.
ALWAYS check the torque tester with approved torque
measuring equipment before use in extreme climatic
conditions.
WARNING
RISK OF ELECTROCUTION
NEVER use the torque tester in areas with high
electromagnetic or ionizing radiation.
NEVER use the torque tester in the open or in damp spaces.
NEVER touch the power unit or plug and socket connections
with wet hands.
ALWAYS use the torque tester with the power unit provided.
ONLY connect the power unit to the power network if the
power unit voltage and power unit frequency specified agree
with the supply voltage and supply frequency of the power
network.
ONLY connect undamaged power units and supply lines to
the torque tester.
NEVER cover power units that are connected.
1.2 Personal Protective Gear
ALWAYS wear the following personal protective equipment
when using the torque tester. The torque wrench can slip or
break, causing SERIOUS INJURY or DEATH:
EYE PROTECTION designed to protect you from flying
objects (see ANSI/ISEA Z87.1) must be worn when using the
torque tester.
Flying objects can cause SERIOUS INJURY to your
eyes.

8
EN
SAFETY GLOVES must be worn when using the torque
tester.
The torque wrench can slip or break causing SERIOUS
INJURY to your fingers and hands.
SAFETY SHOES with slip-resistant soles and steel toe caps
(see ASTM F2413-05) must be worn when using the torque
tester.
Falling parts can cause SERIOUS INJURY to feet and
toes.
1.3 Intended Use
The torque tester is designed to test clockwise releasing
torque wrenches.
DO NOT use the torque tester for any other purpose.
MISUSE can lead to SERIOUS INJURY or DEATH.
DO NOT allow children to use the torque tester.
1.4 Handling
WARNING
Unsafe use and improper handling can cause SERIOUS
INJURY or DEATH. Take the following safety precautions to
prevent injuries and property damage:
ALWAYS check the torque tester, particularly the
adaptor and the housing, as well as the accessory parts,
for visible damage prior to use.
NEVER use a damaged torque tester.
NEVER use a torque tester and accessory parts that
have been modified.
NEVER modify a torque tester and accessory parts.
ALWAYS apply the torque tester in the direction of
rotation specified. Follow the direction of the rotation
arrow.
ALWAYS use standard accessory parts or parts
approved by the manufacturer.
ALWAYS transport the torque tester in shockproof
packaging materials.

9
EN
1.5 Work Environment
ALWAYS use the torque tester in a safe work environment.
Keep the work area clean and tidy.
Use the torque tester in a large and secured area.
The work area must be free of high dust concentration.
NEVER use the torque tester in the open or in damp
spaces.
NEVER use the torque tester in areas with high
electromagnetic or ionizing radiation.

10
EN
2. Product Description
1. Base Plate
2. Drive
3. Display
4. Plug and Socket Connection/Power Supply
5. RS232 Interface
6. Wrench Socket
7. Extension Piece
8. Transport Handle
(8612-3150 only)
6
3
2
1
4
5
3
2
1
6
5
4
1
2
3
5
4
8
7

11
EN
2.1 Scope of Delivery
Electronic Torque Tester
Power Unit
100 – 240 V; 50 – 60 Hz; maximum 500 mA
Note: See rating plate.
Wrench Sockets
(1x extension piece for 8612-3150) (WAF and drive
according to design size)
Operating Instructions
Calibration Certificate
Shipping Package
RS232 Cable
3. Using the Torque Tester
ALWAYS read Section 1 (Important Safety Information)
BEFORE using the torque tester.
The instructions describe the use of the following product
types:
Torque tester with external hexagon or internal square
adaptor on the side
Torque tester with external hexagon adaptor on the front
The test process is represented schematically by a torque
tester with side adaptor (external hexagon) for the torque
wrench. The procedures for the test process using the front
adaptor for the torque wrench are exactly the same.
The direction of rotation is clearly marked on the torque tester
housing.

12
EN
3.1 Terms Used
Taring: Null balancing; the torque is set to “0”.
First Peak: Break point detection (the torque wrench's
release torque is displayed).
Calibration: Testing measurement accuracy.
Torque
Wrench: Releasing torque wrench according to
DIN EN ISO 6789 Type II.
3.2 Mounting the Torque Tester
WARNING
NEVER use the torque tester if it is not fastened on a solid
surface using adequate fasteners (see below).
ALWAYS make sure using the torque tester will not cause the
mounting surface to tip over.
NEVER use the torque tester in the open or in damp spaces.
For fastening on a suitable surface, Gedore recommends
hexagon or cylinder head screws (4 piece) size M8 with
minimum strength class 8.8 (M10 with minimum strength
class 8.8 for 8612-3150), with suitable washers and nuts.
ALWAYS position the unit as not to create any pinch points
between the torque tester, the torque wrench, and the
mounting surface.

13
EN
a b
Model No. [inch] [mm] [inch] [mm]
8612-012 3.35 85 3.55 90
8612-050 3.35 85 3.55 90
8612-300 3.35 85 3.55 90
8612-1000 4.52 115 6.89 175
8612-3150 4.52 115 11.02 280
d t
Model No. [inch] [mm] [inch] [mm]
8612-012 0.35 9 0.20 5
8612-050 0.35 9 0.20 5
8612-300 0.35 9 0.20 5
8612-1000 0.35 9 0.40 10
8612-3150 0.43 11 1.18 30
3.3 Activating / Deactivating
WARNING
ALWAYS remove all accessory parts, torque wrenches,
and other parts from the adaptor prior to activating the torque
tester. Non-compliance can result in faulty screw connections
and potentially in SERIOUS INJURY or DEATH.
WARNING
RISK OF ELECTROCUTION
NEVER use the torque tester in areas with high
electromagnetic or ionizing radiation.
NEVER use the torque tester in the open or in damp spaces.
NEVER touch the power unit or plug and socket connections
with wet hands.
ALWAYS use the torque tester with the power unit provided.

14
EN
ONLY connect the power unit to the power network if the
power unit voltage and power unit frequency specified agree
with the supply voltage and supply frequency of the power
network.
ONLY connect undamaged power units and supply lines to
the torque tester.
NEVER cover power units that are connected.
3.3.1 Activating
Attach the power unit connection cable
to the torque tester. Then plug the
power unit into the socket.
The torque tester activates
automatically at this stage.
Automatic taring follows.
The unit is ready for use when the
value “ 0 0 0 0 ” (with decimal point
depending on the model) is displayed.
3.3.2 Deactivating
To deactivate the torque
tester, first unplug the power
unit from the socket.
Then remove the power plug
connection cable from the
torque tester.
3.4 Taring the Torque Tester
Once the torque tester is activated, “ 0 0 0 0 ” appears in the
display. If the torque tester displays a different value in the
unloaded state, the torque tester has to be tared again.
For this purpose, pull the power plug and wait at least
5 seconds before plug in again. The torque tester will begin
the automatic taring process again.

15
EN
3.5 Switching the Units of Measurement
NOTICE.
The torque tester can be switched between "N·m" and "lbf·ft"
units ("lbf·in" for 8612-012).
Once the torque tester has been activated, the current units
are indicated by a bar in the display next to the imprinted unit.
You can change the units by applying a minimum
counterclockwise torque (see the table below) for at least
2 seconds. Then the bar in the display will move to the
position of the alternative units imprinted on the cover plate.
Minimum Counterclockwise Torque
Model No. [lbf·ft] [N·m]
8612-012 > 13.3 > 1.5
8612-050 > 3.7 > 5
8612-300 > 11.1 > 15
8612-1000 > 18.5 > 25
8612-3150 > 110.6 > 150
3.6 RS232 Interface and Connection to a Computer
You can connect the torque
tester to a RS232 interface
on a computer. With this, test
values can be transferred to
the computer. Use the
connecting cable (9-pin Sub-
D socket / 3.5 mm 3-pin jack)
provided for the connection.
Use a terminal program
suited for your operating
system and your hardware
for communicating with the
torque tester. The interface in
the torque tester is always
active and cannot be
deactivated.
For connection settings, see Section 8 (Technical Data).

16
EN
Output in standard ASCII format. Sample output:
*** GEDORE ***
DREMOTEST-E 8612-050 SNR. 99999
SCHLUESSEL-/Wrench-No.:____________
No. MESSWERT/Value
001 --------------------- 02.68 N.m
002 --------------------- 01.02 N.m
003 --------------------- 01.44 N.m
The header phase and the tally of the reading starts again
when the power supply is plugged in.
3.7 Testing a Torque Wrench with the Torque Tester
WARNING
OVERLOAD HAZARD
The torque tester can be overloaded during use and break
causing SERIOUS INJURY or DEATH.
ALWAYS use only original accessory parts. Accessory parts
not approved by the Gedore may not bear the loads or cause
the torque tester to overload.
ALWAYS inspect the torque tester for damage BEFORE use.
NEVER use a damaged torque tester.
NEVER use the torque tester if it has been dropped, if it has
been used to strike other objects, or if anything has fallen on
it.
WARNING
INACCURATE TORQUE SETTINGS
An out-of-calibration torque tester can result in the failure of
the screw connections, the torque wrench, or the accessories.
This could cause SERIOUS INJURY or DEATH.
An out-of-calibration torque tester may cause the torque
wrench settings to be over- or under- torque, resulting in
SERIOUS INJURY or DEATH.
Always use tested and calibrated torque testers ONLY
(see Section 4.1Testing and Calibrating).

17
EN
WARNING
ALWAYS verify that the torque tester is properly fastened
prior to using the torque tester.
Make sure that you are ALWAYS using the unit according to
specification.
NEVER use the torque tester beyond the permissible torque
range. The torque range is imprinted beneath the display.
ALWAYS put the torque wrench on the adaptor at a 90°
angle.
NEVER use extensions.
ALWAYS use original accessory parts approved by the
manufacturer.
If the resistance changes unexpectedly in the course of
testing, IMMEDIATELY disengage the torque tester or the
torque wrench and check the torque tester and the torque
wrench for damage.
ALWAYS apply the torque tester in the direction of rotation
specified. Follow the direction of rotation arrow.
The torque tester displays the torque applied until a drop in
the torque occurs (e.g. due to the release of the torque
wrench or the disconnection of the power flow).
The maximum torque attained, prior to the drop,
is reproduced for a brief moment in the display. Then the
torque that is currently being applied is displayed again.

18
EN
The torque tester has been
designed to test clockwise
releasing torque wrenches.
The direction of rotation is clearly
marked on the housing.
Put the appropriate wrench
socket on the torque wrench
adaptor. Make sure that the
catching elements latch when
putting the wrench socket on the
torque wrench adaptor. Check for
a secure connection by
vigorously pulling on the wrench
socket.
Check whether the display is
showing " 0 0 0 0 ." If a
discrepancy is indicated in the
display, please proceed as
described in Section 3.4 (Taring
the Torque Tester).
Put the torque wrench including
the wrench socket on the torque
tester adaptor at a 90° angle.
Slip the hexagon socket onto the
hexagon adaptor as far as
possible.
Turn the torque wrench by the
handle slowly and steadily in the
direction of the arrow (follow the
direction of rotation arrow) until a
click sound can be heard and a
slight jerk felt.

19
EN
ALWAYS disengage the torque
tester IMMEDIATELY upon
releasing the torque wrench.
The maximum torque value is
shown in the display.
3.8 Electronic overload notification
WARNING
INACCURATE TORQUE SETTINGS
An out-of-calibration torque tester can result in the failure of
the screw connections, the torque wrench, or the accessories.
This could cause SERIOUS INJURY or DEATH. (Section 4.1)
For model 8612-012
The electronic torque tester emits a constant beeping sound if
too high a torque (> 13 Nm) is applied.
Immediately release the torque electronic tester. Horizontal
lines appear at the upper and lower edge of the display.
Disconnect the electronic torque tester to turn off the beeping
sound.
NOTICE.
To make sure, that the torsion shaft has not been damaged
as a result of an excessive overload having occurred, you
should have the tester checked (calibrated). For this purpose,
please contact our service: www.gedore.com
4. Maintenance
4.1 Testing and Calibrating
WARNING
INACCURATE TORQUE SETTINGS
An out-of-calibration torque tester can result in the failure of
the screw connections, the torque wrench, or the accessories.
This could cause SERIOUS INJURY or DEATH.
An out-of-calibration torque tester may cause the torque
wrench settings to be over- or under- torque, resulting in
SERIOUS INJURY or DEATH.

20
EN
Always use tested and calibrated torque testers ONLY
(see Section 4.1 Testing and Calibrating).
Powerful forces are at work when using the torque tester.
When torque testers are not tested or not serviced there is a
risk that they will not bear the loads or will indicate faulty
tightening torques. ALWAYS take the following safety
information into account in order to prevent SERIOUS
INJURY or DEATH:
NEVER use a faulty torque tester.
ALWAYS have the torque tester calibrated on a regular
basis.
Gedore recommends once every 12 months as the minimally
required calibration interval. Sensitive torque wrenches,
a firm’s own specifications, or quality requirements can also
result in considerably shorter calibration intervals for the
torque tester.
NOTICE.
NEVER neglect recalibrating the torque tester. Improper
calibration can cause the torque tester to be damaged.
Calibration should ONLY be implemented by authorized
specialists, an accredited DKD calibration laboratory, or the
manufacturer.
Every new torque tester comes with a calibration certificate.
The torque tester and the calibration certificate are labeled
with the identical serial number.
Serial Number
This manual suits for next models
4
Table of contents
Languages:
Other Gedore Test Equipment manuals
Popular Test Equipment manuals by other brands

Gossen MetraWatt
Gossen MetraWatt PROFITEST INTRO operating instructions

Seecode
Seecode 20207 manual

GENERAL RADIO COMPANY
GENERAL RADIO COMPANY I559-B operating instructions

DARKSTAR TECHNOLOGIES
DARKSTAR TECHNOLOGIES D340 Guide to Operation

Tektronix
Tektronix TAS 465 Service manual

GE
GE EntelliGuard G instructions