manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. GEM
  6. •
  7. IP Access Controllers
  8. •
  9. GEM DG-101WI User manual

GEM DG-101WI User manual

ACCESS CONTROL
N.O.1
Com.1
N.C.1
123
Relay Relay
Reset
Black: N.O.2
Brown: Com.2
Red: N.C.2
Orange: P1
Yellow: B1
Green: P2
Blue: B2
Purple: Reed
Grey: Reed
Locking Device 1
(Fail-Safe)
Locking Device 2
(Fail-Secure)
Push Button 1
Push Button
2
12Vdc
12Vdc
+
+
+
+
Master Code
reset to
Factory 12345
Contact door reed switch. This reed switch is used to
reset the re-locking time to 0 second when the door
is moved (relay 1). Using N.O. contact in case of door
closed, change over to N.C. when door is moved.
23
1
56
4
89
7
0#
114
70
40
WHITE
BLACK
DG-101WI
DG-101BA
Standalone Keypad Access
• Operating voltage 12~24Vdc
• ABS plastic
• Allows up to 49+50 PIN codes
• Dual relays output for multi control
• Fully programmable via keypad
and master code
• 5 digit codes only
• 3 LED displays with audible indication
SPECIFICATION
•Current draw: Pull in: 60mA/12Vdc; Holding: 15mA/12Vdc.
•Output: Dual relays, N.O./N.C/Com.
•Relays rating: 2A@30Vdc., 0.4A@120Vac.
•Memory volume: 49+50 PIN codes.
Relay 1 is controlled by 001~049 user slots.
Relay 2 is controlled by 050~099 user slots.
All dimensions in mm
58 Access Control
Copyright Gianni Industries, Inc. All Rights Reserved.
P-MU-DG101 Ver. B Publish:2008.10.23 Page: 1/ 3
The DG-101 Digital Keyless Entry system
Operation User's Manual
1. Product Characteristic:
Allows up to 49+50 PIN codes
Dual relays programmable On/Off or pulsed or latched mode
Fully Programmable via keypad and master code
Door Reed Switch Input for Anti-Trailing
3 LED display with audible indication
Non-Volatile Memory
Invalid PIN Lock-out
ABS housing
With vandal resistant screws
ABS or optional luminous keypads
2. Specifications:
Operating Voltage: 12~24 Vdc
Current Draw: Average 15mA, Peak 60mA @ 12Vdc
Input: request-to-exit、Door Reed
Output: Dual relays, N.O./N.C./Com. Output (free voltage contact)
Relays Electric Current: 2A MAX @30Vdc ;0.4A @ 120Vac
Relay Activation Time: (*100、*200)
Strike Time: 1~99 seconds(adjustable)
Strike mode: Access Timer or Latch
Memory Volume: 49+50 PIN codes
Relay 1 is controlled by 001~049 user slots
Relay 2 is controlled by 050~099 user slots
PIN codes: 5 digit codes only
Operating Temperature: -20~+70℃
Ambient Humidity: 5~95% relative humidity non-condensing
Factory Master Code: 12345
Invalid PIN Lock-out: The system will shut down for 60 seconds while 32 codes of
incorrectly Master Codes enrolled or PIN codes attempted.
EPROM: Non-volatile memory, System will retain all programs and codes after a total
loss of power.
Surface mounting Installation:
SMB-750 housing is optional for
surface mount.
This series of request to exit can be
mounted directly in ANSI electrical box
(Flush mount)
Copyright Gianni Industries, Inc. All Rights Reserved.
P-MU-DG101 Ver. B Publish:2008.10.23 Page: 2/ 3
3. The indicator signal chart:
Sound and LED indicator:
Green LED Power on, stand-by
Red LED Relay 1 activated
LED signal
Yellow LED Relay 2 activated
1 Beep Effective PIN codes
2 Beeps Entering 、Exiting from the Program mode
3 Beeps Data computing error 、other operation mistakes
Sound signal
5 Beeps Master Code reset to Factory (12345)
4. Operation Instruction:
Enter Program Mode:
1. Compose twice the master code (Factory master is 「12345」)
→2 beeps →you are now in the "programming mode".
2. After 60 seconds if you have not entered any codes or data, the system will
automatically exit from the programming mode. After 32 wrong codes attempts at the
master code the lockout facility will operate.
Exiting from the program mode:
1. Press「#」to exit from the programming mode.
2. After 60 seconds if you have not entered any codes or data, the system will
automatically exit from the programming mode. After 32 wrong codes attempts at the
master code the lockout facility will operate.
Add PIN codes
Enter the Programming mode, Enter the slot position code 「*001~*099」→?????
Input 5 digit PIN codes→(beep) enrolled Æ(repeat)
Press 「#」to exit from the programming mode, or program other operating.
Note 1: The codes「00000」,「12345」or master code are not be used for PIN code.
Note 2: Relay 1 is controlled by 001~049 user slots, Relay 2 is controlled by 050~099
user slots
To Delete a User Code:
Enter the Programming mode→Press the slot position code of your choice to delete
(example "06") →Press「*006」→「00000」→(beep)→delete→Press「#」to exit
from the programming mode, or programming other operating.
To Program Relocking Timer
Enter the Programming mode,
A. Relay 1:Press「*100」Followed by the number of seconds the relay should
open→「05」=5 seconds(01 ~99 = seconds)→(beep)→enrolled →Press
「#」to exit from the programming mode, or program other operating.
B. Enter「00」Sets the relay to latching mode. (Correct code entered opens the relay,
and the relay stays open until the correct code is entered again).
C. Relay 2:Press「*200」Followed by the number of seconds the relay should
open)→「05 =5 seconds (01 ~99 = seconds). →(beep)→enrolled →Press
「#」to exit from the programming mode, or program other operating.
D. Enter「00」Sets the relay to latching mode. (Correct code entered opens the relay,
and the relay stays open until the correct code is entered again).
Copyright Gianni Industries, Inc. All Rights Reserved.
P-MU-DG101 Ver. B Publish:2008.10.23 Page: 3/ 3
Changing the Master codes:
Enter the Programming mode, Enter「*000」Followed by the new 5 digit master
code→(beep)→enrolled→Enter 「#」to exit from the programming mode, or
program other operating.
Master Code reset to Factory 「12345」
Insert the jumper P1Æ2-3 positionÆ5 audible beepsÆReset successfulÆReturn
Insert the jumper to 2-3 position.
5. Wiring diagram:
Note:
The suggested wire gauge is #22~26 AWG.
The varistor or diode must be connected across the lock terminal (electromagnet...)
operated by the device. The vartistor controls the overload produced by the strike coil
(EMP).
Egresses switch should be N.O. type.

This manual suits for next models

1

Other GEM IP Access Controllers manuals

GEM Gemprox-26M User manual

GEM

GEM Gemprox-26M User manual

GEM BTS-200 User manual

GEM

GEM BTS-200 User manual

GEM 962 EZ-Plus User manual

GEM

GEM 962 EZ-Plus User manual

GEM E-ACCESS E1196 User manual

GEM

GEM E-ACCESS E1196 User manual

GEM ST-630E User manual

GEM

GEM ST-630E User manual

GEM EX-827 User manual

GEM

GEM EX-827 User manual

GEM GEM 981-10 User manual

GEM

GEM GEM 981-10 User manual

GEM ST-630E User manual

GEM

GEM ST-630E User manual

GEM GEM DG-700 User manual

GEM

GEM GEM DG-700 User manual

Popular IP Access Controllers manuals by other brands

Akuvox A092 Series Administrator's guide

Akuvox

Akuvox A092 Series Administrator's guide

Sicunet Neptune Series installation instructions

Sicunet

Sicunet Neptune Series installation instructions

BioSmart 5M-O installation guide

BioSmart

BioSmart 5M-O installation guide

Keyscan CA8WL-AL installation guide

Keyscan

Keyscan CA8WL-AL installation guide

ADTRAN ATLAS 550 Q&A

ADTRAN

ADTRAN ATLAS 550 Q&A

Samsung SSA-P400 user manual

Samsung

Samsung SSA-P400 user manual

KALE KILIT KD050/10-360 INTRODUCTION AND USER MANUAL

KALE KILIT

KALE KILIT KD050/10-360 INTRODUCTION AND USER MANUAL

Schlage Panel Interface Module RS485 Installation & operating instructions

Schlage

Schlage Panel Interface Module RS485 Installation & operating instructions

EverFocus EBC890 user guide

EverFocus

EverFocus EBC890 user guide

Navkom inokey comfort instruction manual

Navkom

Navkom inokey comfort instruction manual

Dahua ASI6213J-FT user manual

Dahua

Dahua ASI6213J-FT user manual

Anviz T50 user manual

Anviz

Anviz T50 user manual

ZKaccess ZKTeco OP-200 quick start guide

ZKaccess

ZKaccess ZKTeco OP-200 quick start guide

IDTECK iTDC Troubleshooting

IDTECK

IDTECK iTDC Troubleshooting

Roger MC16-PAC-1-KIT installation manual

Roger

Roger MC16-PAC-1-KIT installation manual

Citadele DIGIPASS 700 operating instructions

Citadele

Citadele DIGIPASS 700 operating instructions

Moniteq Crypto-Lock CC-8521B instruction manual

Moniteq

Moniteq Crypto-Lock CC-8521B instruction manual

Rosslare AYC-Q4 Series manual

Rosslare

Rosslare AYC-Q4 Series manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.