CONTROL FUNCTIONS
CONTROL PANEL FEATURES GM4600iAEFIC
10 11
12
13
14
15
① Light Switch: Press the first time to turn on the LED light
and press the second time to turn off the LED light.
② LED Light: 1. The LED light can be used normally when
the generator is running, and the LED light cannot be used
when the generator shuts down.
2. If the LED light is not turned off, press the one-key start
button (or remote control key) to stop the generator while the
main switch is not turned off, the LED light will automatically
turn off after 30 seconds.
3. Press the one-key start button (or remote control key) to
stop the generator and also turned off the main switch, the
LED light will go out immediately.
③ SwitchSTART/STOP : Press this button, the engine can
start and stop.
④ Low Idle Switch: When turned to the ON position, the
engine will sense the load needed and run at a slower RPM
to save fuel.
⑤ Reset: If the inverter is overloaded, the reset breaker will
trip. The engine will continue to run, but there will be no
output from the inverter. Unplug the devices and reduce the
load. Push in the reset breaker to reset it.
⑥ DC Cigarette Lighter Outlet: 12V DC 8.3A.
⑦ Parallel Connectors: To increase AC power output, the
connector sockets are used to connect the two same type
generators with special parallel kit GM6000SPK sold by
GENMAX. The connector sockets is only used to connect two
inverter generators. They can not used for AC power output.
The special paralleling kit GM6000SPK shall be purchased
separately, and they shall be approved by certification body.
⑧ Series Connectors (120/240V OUTPUT): When using
parallel kits, two 120V generators can output 240V by
connecting this interface.
⑨ Ground Terminal: The ground terminal is used to
externally ground the inverter.
⑩ 120V AC 30A TT-30R Outlet: The outlet is capable of
carrying a maximum of 30 amps.
⑪ 120V AC 20A 5-20R Outlet: The outlet is capable of
carrying a maximum of 20 amps.
⑫ Battery Charging Port: Charge the generator battery.
⑬ CO Alarm: Flashing red light: dangerous levels of carbon
monoxide gas have built up leave immediately until area has
aired out. Move generator to well-ventilated area before
operation. Flashing yellow light: carbon monoxide sensor
malfunction. Sensor needs service.
⑭ AC Protector: If the generator is overload, the AC
protector will trip to block current.
⑮ DC Protector: If the generator is overload, the DC
protector will trip to block current.
⑯ Main Switch: Manage battery power and shutdown. Tip: If
you do not use the generator for more than 7 days (168
hours), please press the main switch to the "OFF" position,
which can prevent the battery from running out.