Geovent HVU-Lite 3 Series User manual

Version 1.0 13.12.17
HIGH VACUUM UNIT
HVU-Lite - 3 and 5
INSTRUCTION MANUAL
www.geovent.com

2
Contents
1.0 General safety precautions ................. 2
1.1 Danger................................. 2
1.2 Field of application. . . . . . . . . . . . . . . . . . . . . . . . 2
1.3 Technical data .......................... 2
1.4 Construction – table of dimensions ........... 3
2.0 Installation .............................. 3
2.1 Optional equipment ....................... 4
2.2 Trial run – exact adjustment ................ 4
3.0 User instruction – application ............... 4
4.0 Maintenance ............................ 4
4.1 Exchange of filter medium.................. 4
4.2 Trouble shooting ......................... 5
5.0 Liability. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
6.0 Declaration of conformity................... 5
6.1 Enclosures.............................. 6
1.0 General safety precautions
IMPORTANT – Please study all the instructions before
mounting and commissioning.
Please keep these instructions in a safe place and in-
struct all users in the function and operation of the pro-
duct.
Exchange of filter/maintenance should only be imple-
mented after studying section 4 thoroughly.
Avoid the dismantling of any factory-mounted parts, sin-
ce it impedes the commissioning of the equipment.
All electrical installations must be carried out by an
authorised electrician.
1.1 Danger
The HVU-Lite is not to be used for the extraction of
explosive media.Use HVU-Lite ATEX version if this is
your need.
Dismantling parts on the HVU whilst in operation is po-
tentially lethal.
Always disconnect the HVU from the mains, when
mounting parts or servicing the Unit.
1.2 Area of application
The Geovent High Vacuum Unit - HVU - (of more than
20 kPa) is suitable for vacuum various dust applicati-
on, from car body work to pharmaceutical. The Unit is
equipped with a two-step filter cyclone with an automa-
tic/pneumatic cleaning system and has a filtration level
of 99.9%.
The Unit may be used for the extraction of grinding dust
from hand-held rotor grinders, stationary belt sanders
and bench grinders, brake dust from cars and trucks as
well as ordinary workspace cleaning, etc.
1.3 Technical data
Model Output
[kW]
Power
consump-
tion 100%
load
Max. air flow
[m³/h]
HVU-Lite 30 3 6,8A 350
HVU-Lite 55 5,5 11,6A 500
Model
Max.
Vacuum
[kPa]
Filter area
[m²]
Filtration
effect accor-
ding to
BIA-test
HVU-Lite 30 23 7,5 99,9%
HVU-Lite 55 21 7,5 99,9%
Model
Sound
pressure
level
according
to
ISO-3746-
1979
Compres-
sed air
tank w/1”
connec-
tion
Collection
bucket
HVU-Lite 30 72 dBA 4 Liters 18 Liters
HVU-Lite 55 74 dBA 4 Liter s 18 Liters
Model
Cabinet +
cyclone
ø700
Corrosion
class Weight
HVU-Lite 30 Painted ll 120 kg
HVU-Lite 55 Painted ll 140 kg
Temperature extracted air Max 150°C
Temperature surroundings Max -10°C - +50°C
Relative humidity must be <90%
The sound level depends on several factors; For examp-
le where the High Vacuum Unit is placed (indoors/out-
doors), the size of the room, the temperature of the
surroundings, the acoustics and also the connection
(hose><pipe) of the Unit has an effect on the sound le-
vel.
Graphs of pressure drop for the High Vacuum Unit
Blue line indicates 3 kW - Red line indicates 5.5kW
Full print line indicates 50Hz - Stiplet 60Hz
Instruktionsmanual Højvakuumunit – HVU-Lite 30 & 55
29-01-2007 ver. 1.0 www.geovent.com Side 1/6
Indholdsfortegnelse
1.0 Generelle sikkerhedsforskrifter
1.1 Fare
1.2 Anvendelsesområde
1.3 Tekniske data
1.4 Konstruktion - måltabel
2.0 Installation
2.1 Ekstraudstyr
2.2 Testkørsel – finjustering
3.0 Brugerinstruktion – anvendelse
4.0 Vedligeholdelse
4.1 Udskiftning af filtermedie
4.2 Problemløsning
5.0 Ansvar
6.0 Overensstemmelseserklæring
6.1 Bilag
1.0 Generelle sikkerhedsforskrifter
VIGTIGT - Læs hele vejledningen igennem før
montering og ibrugtagning.
Opbevar denne betjeningsvejledning og giv alle
brugere instruktion i, hvordan produktet fungerer
og betjenes.
Udskiftning af filter/ vedligeholdelse, bør kun ske
efter nøje gennemlæsning af afsnit 4.
Undlad at demonterer fabriksmonterede dele, da
dette besværliggør ibrugtagningen af anlægget.
Alle EL installationer bør kun foretages af en
autoriseret elektriker.
1.1 Fare
Eksplosive medier – HVU-Lite’en er ikke egnet til
udsugning af aluminiums-, mel-, tekstil- og
træstøv samt andre medier som er forbundet med
eksplosionsfare uden specifikt tilsagn fra Geovent
A/S. Vær derfor særdeles opmærksom på ikke at
udsuge et af de nævnte medier, da der er tale om
livsfare ved eksplosion.
Det er forbundet med livsfare at begynde at
demontere dele på HVU-Lite’en mens denne er i
gang.
Ved montage eller service af HVU-Lite’en, skal
strømmen altid afbrydes.
1.2 Anvendelsesområde
Geovent højvakuumunit HVU-Lite (over 20 kPa)
anvendes bl.a. til støvsugning ved klargøring af
biler, til slibestøvsudsugning f.eks. ved slibning af
karosseri eller i forbindelse med energi-arme.
Unitten er forsynet med en to-trins filtercyklon
med et trykluftsrensesystem og en filtreringsgrad
på 99,9%.
Unitten kan f.eks. anvendes til udsugning af
slibestøv fra håndholdte rotorslibere, faste
båndpudsere og bænkslibere, bremsestøv fra
person- og lastbiler samt almindelig
arbejdspladsrengøring m.v.
1.3 Tekniske data
Model Effekt
[kW]
Strømforbrug
100%
belastning
Maksimal
luftmængde
[m³/h]
HVU-Lite 30 3 6,8A 350
HVU-Lite 55 5,5 11,6A 500
Model
Max.
Vakuum
[kPa]
Filterareal
[m²]
Filtrerings-
grad iht.
BIA-test
HVU-Lite 30 23 7,5 99,9%
HVU-Lite 55 21 7,5 99,9%
Model
Lydtryks-
niveau iht.
ISO-3746-
1979
Tryklufttank
m/1” tilslutn.
Opsamlings
-spand
HVU-Lite 30 72 dBA 4 Liter 12 Liter
HVU-Lite 55 74 dBA 4 Liter 12 Liter
Model Kabinet +
cyklon ø700
Korrosions-
klasse Vægt
HVU-Lite 30 Lakeret ll 120 kg
HVU-Lite 55 Lakeret ll 140 kg
Temperatur udsugede luft
Temperatur omgivelser
Max 150°C
Max -10°C - +50°C
Relativ luftfugtighed skal være <90%
Lydniveauet afhænger af flere faktorer. F.eks.
højvakuumunittens placering (indendørs/
udendørs), størrelsen af rummet, temperaturen i
omgivelserne, rumklang og tilslutningen
(slange><rør) af unitten har også betydning for
lydniveauet.
Tryktabskurver over Højvakuumunit
Blå linie angiver 3 kW – Rød linje angiver 5,5kW
Fuld optrykket linje angiver 50Hz – Stiplet 60Hz

33
Power curve for High vacuum unit
Blue line indicates 3 kW - Red line indicates 5.5kW
Full print line indicates 50Hz - Stiplet 60Hz
1.4 Construction
Shield: Epoxy painted steel plate.
Filter medium: 99.9% filtration efficiency. Expected life
for normal operation: 4,000-8,000 hours.
Engine/vacuum pump: IP-54 standard engine with by-
pass fan in cast aluminium. Expected life for normal ope-
ration: 20,000 hours.
Automatics: Customize control panel placed inside.
Dimensions:
2.0 Installation
The HVU should be installed indoors, for example in an
engineering room with good ventilation in order to secure
perfect operation. For outdoor installation, always pla-
ce in an open shed as a minimum. THE SURFACE
TREATMENT OF THE HVU IS NOT SUITABLE FOR
OUTDOOR APPLICATION, SINCE THE RISK OF WA-
TER PENETRATING THE CYCLONE IS INCREASED
AND FURTHERMORE, THE ELECTRONICS COMPO-
NENTS MAY NOT FUNCTION IN FROSTY WEATHER.
The HVU Lite is supplied in complete/assembled condi-
tion and it has been pre-programmed, ready for conne-
ction to the mains.
Before mounting, please make sure that the optimum
installation area is selected. Should it be placed indoors
or outdoors? Is there space enough for the satisfactory
installation and service of the HVU? What about opti-
mum connection possibilities for piping and automatics?
If at all possible, please avoid bends just before the inlet
and after the outlet, since otherwise it could reduce the
capacity of the HVU.
For outdoor mounting, please take the following aspects
into consideration: Any noise nuisance for the neighbou-
rs, defects due to frost and keep the engine out of hea-
vy showers. Therefore, we recommend building a shed
around the HVU in order to protect it from the weather
and to shield against noise.
The following installation should only be carried out by
a trained fitter.
Procedure:
1. The HVU Lite is placed on a solid foundation (e.g. on
a concrete floor), where there is no danger of vibration
transmission. Also, please ensure that the filter can be
exchanged (i.e. as a minimum a free height of 800 mm
is required).
2. Connect the piping to the HVU Lite. On the inlet side,
the pipe may be fixed by means of a spring lock system.
Remember to seal the connection with filler and/or tape!
3. In order to secure free mixing, the outlet should be
taken two metres up above the roof top (up in the air)
with an air velocity of 8 m/s as a minimum.
4. The whole plant/piping system should always be tho-
roughly checked for leaks, which should be sealed. The
plant may not be taken into operation for 24 hours.
Connection of the fan to the mains:
5.The connection of the electric components of the HVU
should only be carried out by an authorised electrician.
6.For connection options, please refer to the diagram on
page 6.
Ø76mm
415mm
545mm
Ø76mm 275mm
1040mm
250mm
1105mm
670mm
Instruktionsmanual Højvakuumunit – HVU-Lite 30 & 55
29-01-2007 ver. 1.0 www.geovent.com Side 2/6
Effektkurver for Højvakuumunit
Blå linie angiver 3 kW – Rød linje angiver 5,5kW
Fuld optrykket linje angiver 50Hz – Stiplet 60Hz
1.4 Konstruktion
Afskærmning: Pulver lakeret stålplade.
Filtermedie: gnistsikkert aluminiumscoated
polyesterfilter AluTex® med 99,9 %
filtreringsgrad. Forventet levetid ved normal brug:
4000-8000 timer.
Motor/vakuumpumpe: IP-54 normmotor med
sidekanalsblæser i støbt aluminium. Forventet
levetid ved normalt brug: 20.000 timer
Automatik: Styretavle i ABS-plast IP-55
Vakuumbegrænser: Ekstraudstyr
Styretavle: Trykluftrensning sker via trykknap på
siden af unitten. Automatisk rensesystem og
start/stop er ekstraudstyr.
Måltabel
2.0 Installation
HVU Lite’en bør installeres indendørs i f.eks.
teknikrum med god ventilation for fejlfri drift.
OVERFLADEBEHANDLINGEN PÅ HVU LITE’EN
ER IKKE EGNET TIL UDENDØRS PLACERING,
DA RISIKOEN FOR VAND I CYKLONEN ØGES,
RISIKO FOR RUST PÅ UNIT, SAMT AT
ELEKTRONIK-KOMPONENTERNE IKKE
FUNGERE I FROSTVEJR.
Inden montering, overvej da først det optimale
installationsområde. Er der plads til at der kan
udføres tilfredsstillende installation/ service af
HVU-Lite´en? Er der optimale tilslutningsmulig-
heder for rørføring og automatik? Undgå for så
vidt muligt bøjninger umiddelbart før indsuget og
efter afkastet, idet dette ellers vil nedsætte
ydeevnen for HVU Lite. Ved udendørs montering
skal der tages højde for evt. støjgener hos
naboer, fejl grundet frost og for at motoren undgår
regn. Derfor bør der opbygges skur omkring HVU-
Lite der skærmer mod støj, vejr og vind.
Følgende installation bør kun ske af uddannet
montør.
Fremgangsmåde:
1. HVU-Lite’en placeres på et solidt fundament
(f.eks. cement gulv), hvor der ikke er
mulighed for at vibrationer overføres. Der
skal desuden tages højde for om man kan
foretage filterskift (dvs. at der minimum er
800 mm frihøjde.)
2. Rørføringen tilsluttes HVU-Lite’en. På
indløbssiden kan røret f.eks. fastgøres ved
hjælp af et snaplåsesystem. Husk at tætne
samlingen med fugemasse og/eller tape!

4
2.1 Mounting of optional equipment
Mounting of a repair switch
A repair switch must be connected in order to comply
with the EN 60 204-1 standard, according to which a
manual switch must be fitted. Typically, the switch will be
placed 2 – 3 metres from the Unit and it must be clearly
visible.
Mounting of control panel, with build in frequency
inverter and PID regulation
Please see separate manuals for specific details.
2.2 Trial run – exact adjustment
When the installation has been completed, please check
whether there is any vibration or noise nuisance from the
HVU.
Please control that the complete plant is totally tight. If
any creaking noises are emitted, please locate the lea-
kage and seal it with filler.
Furthermore, we recommend checking whether the HVU
supplies the volume of air, for which the equipment has
been dimensioned. Measure the air volume and ensure
that it does not exceed the amperage of the engine.
3.0 Application – user instruction
The HVU should not be in operation for longer periods of
time (more than 15-30 min.) without opening the valves.
There is a built in vacuum safety valve, which should en-
sure the motor from meltdown, but we don’t recommend
testing it for longer periods of time, in case the unit is
placed in a warm location.
4.0 Maintenance
At least once annually, the whole point suction plant
should be overhauled by an authorised serviceman.
Periodic maintenance:
• All electric parts should be checked annually.
• In principle, the vacuum pump/engine is maintenan-
ce-free due to the factory-mounted completely closed
special ball bearings, which do not require any mainten-
ance. Exchange of worn bearings should only be carried
out by an electro-company.
• The bin should be changed when ever it is full. The bin
sensor should give an alarm signal to the control panel.
Once annually this procedure should be tested for fun-
ctionality.
• We recommend that the cleaning cycle is activated at
least once a day, in order to ensure longer living time on
the filters.
4.1 Exchange of filter medium
The collection bucket should be emptied when approx.
two thirds of it is full, since otherwise it may further load
the filter medium. The filter medium should be exchan-
ged after approx. 4,000-8,000 hours of operation or max.
4 years. Partly, this depends on the load on the filter, for
example whether it has been used in connection with
welding or grinding, etc.
Procedure:
1. Disconnect the Unit on the repair switch. Please en-
sure that the switch cannot be activated during the ser-
vice operation.
2. Disconnect/dismantle the compressed air connection.
3. Before dismantling the dusty filter, it is important that
the service technician is equipped with the necessary
personal safety outfit, i.e. breathing mask and gloves,
which comply with the rules of the Working Environment
Service regarding work with polluted dust.
4. Subsequently, the collection bucket is dismantled
by means of the fixed spring locks. Now, with care the
bucket may be taken out. The contents of the bucket are
now to be destroyed in an environmentally sound man-
ner in accordance with the current rules.
5. The bucket is returned and fixed under the cyclone.
Instruktionsmanual Højvakuumunit – HVU-Lite 30 & 55
29-01-2007 ver. 1.0 www.geovent.com Side 3/6
3. For at sikre fri opblanding, bør afkastet føres
to meter over tagryg mod atmosfæren med
en afkast-hastighed på minimum 8 m/s.
4. Hele anlægget/rørføringen bør altid efterses
grundigt for utætheder. Utætheder seales.
Anlægget må ikke anvendes i de
efterfølgende 24 timer.
Tilslutning af ventilator til El-nettet:
5. Tilslutningen af HVU-Lite’ens elektriske
komponenter bør kun udføres af autoriseret
EL-installatør.
6. For tilslutningsmuligheder se diagram side 6.
2.1 Montering af ekstraudstyr
Montering af reparationsafbryder
Her er afbilledet en HVU, men samme gælder for HVU-Lite.
Reparationsafbryder skal tilsluttes for at leve op til
EN 60 204-1 standarden, hvor der skal tilsluttes
en manuel afbryder. Afbryderen vil typisk placeres
2 – 3 meter fra unitten og skal være tydelig synlig.
Flowguard
I Danmark skal alle udsugningsanlæg forsynes
med kontrolanordning til kontrol af korrekt sug iht.
Arbejdstilsynet. Se separat vejledning herom.
Montering af frekvensomformer
For tilslutningsmuligheder for frekvensomformer
se diagram på side 6
For indstillingsmuligheder for ekstern frekvens-
omformer se separat medfølgende manual
(Digidrive).
For detaljere diagram se bilag - bagerste sidst.
2.2 Testkørsel - finjustering
Efter endt installation tjek da, om der er rystelser
eller lydgener ved HVU-Lite’en.
Tjek at hele anlægget er fuldstændigt tæt. Ved
pibelyde, bør utætheden lokaliseres og tætnes
med fugemasse.
Det kan anbefales at tjekke om HVU-Lite’en
levere den luftmængde som anlægget er
dimensioneret til. Mål derfor luftmængden og sørg
for at den ikke overstiger motorens ampere-tal.
3.0 Anvendelse - Brugerinstruktion
HVU-Lite må ikke køre i længere perioder (mere
end 45 min) uden åbne udtag i kanalsystemet, da
pumpen ellers vil overophede og gå i stykker.
Anvend evt. den indbyggede start/stop funktion.
Instruktionsmanual Højvakuumunit – HVU-Lite 30 & 55
29-01-2007 ver. 1.0 www.geovent.com Side 3/6
3. For at sikre fri opblanding, bør afkastet føres
to meter over tagryg mod atmosfæren med
en afkast-hastighed på minimum 8 m/s.
4. Hele anlægget/rørføringen bør altid efterses
grundigt for utætheder. Utætheder seales.
Anlægget må ikke anvendes i de
efterfølgende 24 timer.
Tilslutning af ventilator til El-nettet:
5. Tilslutningen af HVU-Lite’ens elektriske
komponenter bør kun udføres af autoriseret
EL-installatør.
6. For tilslutningsmuligheder se diagram side 6.
2.1 Montering af ekstraudstyr
Montering af reparationsafbryder
Her er afbilledet en HVU, men samme gælder for HVU-Lite.
Reparationsafbryder skal tilsluttes for at leve op til
EN 60 204-1 standarden, hvor der skal tilsluttes
en manuel afbryder. Afbryderen vil typisk placeres
2 – 3 meter fra unitten og skal være tydelig synlig.
Flowguard
I Danmark skal alle udsugningsanlæg forsynes
med kontrolanordning til kontrol af korrekt sug iht.
Arbejdstilsynet. Se separat vejledning herom.
Montering af frekvensomformer
For tilslutningsmuligheder for frekvensomformer
se diagram på side 6
For indstillingsmuligheder for ekstern frekvens-
omformer se separat medfølgende manual
(Digidrive).
For detaljere diagram se bilag - bagerste sidst.
2.2 Testkørsel - finjustering
Efter endt installation tjek da, om der er rystelser
eller lydgener ved HVU-Lite’en.
Tjek at hele anlægget er fuldstændigt tæt. Ved
pibelyde, bør utætheden lokaliseres og tætnes
med fugemasse.
Det kan anbefales at tjekke om HVU-Lite’en
levere den luftmængde som anlægget er
dimensioneret til. Mål derfor luftmængden og sørg
for at den ikke overstiger motorens ampere-tal.
3.0 Anvendelse - Brugerinstruktion
HVU-Lite må ikke køre i længere perioder (mere
end 45 min) uden åbne udtag i kanalsystemet, da
pumpen ellers vil overophede og gå i stykker.
Anvend evt. den indbyggede start/stop funktion.

555
6. The top/lid of the cyclone is dismantled by uncoupling
the spring lock, and then the lid with the compressed
air tank is removed. Make sure first to disconnect the
supply of compressed air and the power supply and not
to damage the compressed air tank, when it is put aside.
7. Subsequently, with a 17 mm box spanner remove the
three M10 bolts, which attach the filter medium to the
Unit.
8. The polluted filter medium is carefully lifted up and
placed in a large rubbish bag, which is then properly se-
aled up.
9.The new filter medium is inserted and fixed to the Unit
with three 10 mm bolts.
10. The top/lid is carefully returned and fixed with a
spring lock. (Remember to connect to power and com-
pressed air again!).
11. Subsequently, the polluted filter medium is sent to
destruction at the nearest waste disposal plant.
4.2 Trouble shooting
In case of problems with reduced pressure or volume of
air, the points mentioned below may be followed when
attempts are made to solve the problems:
The volume of air or the pressure has fallen to below the
indicated volume/pressure.
• Wrong direction of rotation of the fan wheel. May be
caused by wrong electrical installation. Please double
check the direction of rotation. Change two phases.
• The channel system is not tight.
• Poor inlet/outlet options close to the vacuum pump
may reduce the capacity (e.g. 90° bend just before the
inlet).
• Damaged wheel.
• The rate of rotation has been set to a lower level.
• If the temperature deviates substantially from the la-
boratory measurements, where the temperature was
20°C with an atmospherical pressure of 101.4 kPa.
• The dampers have not been properly adjusted.
• The channel or the Unit has been blocked by a screwdri-
ver, for instance.
Vibrations and noise.
• The foundation is not level/stable.
• Elements coming from outside have penetrated the
Unit/channel system.
• Damaged wheel or engine.
• The wheel is loose.
• The wheel is running in the wrong direction.
• Loose bolts or screws.
The engine is overloaded.
• The cabling to the engine is wrong.
• Defective engine – please contact the distributor!
5.0 Liability
Warranty
Geovent A/S grants a warranty for products, which are
defective; when it can be proved that the defects are due
to poor manufacture or materials on the part of Geovent.
The warranty comprises remedial action (reparation or
exchange) until one year after date of shipment. No
claims can be made against Geovent A/S in relation to
loss of earnings or consequential loss as a result of de-
fects on products from Geovent.
Wear parts like fan wheels etc. are not included in the
warranty.
User liability
In order for Geovent to be capable of granting the decla-
red warranty, the user/fitter must follow this Instruction
Manual in all respects.
Under no circumstances may the products be changed
in any way, without prior written agreement with Ge-
ovent A/S.
6.0 Declaration of conformity
Hereby declares that:
The product: High Vacuum Unit
Models: HVU Lite
has been manufactured in compliance with the directi-
ons of the Directive Council of 14 June 1989 in common
approximation to the legislation of the member states
regarding machine safety (89/392/EEC amended by the
directive 91/368/EEC) with special reference to appen-
dix 1 in the Directive regarding basic health and safety
requirements in connection with the construction and
manufacturing of machinery.
Date: 13/12-17
Position: Managing Director
Name: Thomas Molsen
Signature:

6
Instruktionsmanual Højvakuumunit – HVU-Lite 30 & 55
29-01-2007 ver. 1.0 www.geovent.com Side 1/6

7
UNI-EL A/S
St. Fjelstervangvej 22
6933 Kibæk , DK
Tel. +45 97 16 63 11
Fax. +45 97 16 63 66
Styring - Hovedstrøm
5,5 KW Motor starter, med mulighed for extern start/stop og efterløbstid
Side 3Uni EL Tegnings Nr : 3-173-025 Oprettelsesdato : 10-12-02 Revisionsdato : 29-03-06 af 6
Konstruktør : KBRevisionsnr : V02-01
This manual suits for next models
3
Table of contents
Other Geovent Vacuum Cleaner manuals
Popular Vacuum Cleaner manuals by other brands

Nilfisk-Advance
Nilfisk-Advance VP600 Original instruction

Kenmore
Kenmore AllergenSeal DU2109 user manual

Black & Decker
Black & Decker BDH1850SM instruction manual

LG
LG VB78 H Series manual

Tower Hobbies
Tower Hobbies TCWS AQUAJET PLUS quick start guide

Festool
Festool CLEANTEC CTLC MINI I Original instructions