German Light Products impression X4S User manual

Instruction Manual
from software version: V1.09
(Instruction version: 1.1)
e-mail: service@glp.de
Internet: http://www.glp.de

GLP
German Light Products GmbH (Instruction version: 1.1) / from software version: V1.09 2
Notes:

GLP
German Light Products GmbH (Instruction version: 1.1) / from software version: V1.09 3
Table of contents
1Description of Device............................................................................................. 4
1.1 Safety Instructions............................................................................................ 5
2Preparation and Installation .................................................................................. 6
2.1 Safety information............................................................................................ 6
2.2 Mounting.......................................................................................................... 7
2.2.1 Operating on the Floor (Upright)............................................................ 8
2.2.2 Mounting in hanging position................................................................8
2.2.3 Mounting in sideways Position..............................................................8
2.3 Securing the Fixture......................................................................................... 9
2.4 Connections..................................................................................................... 9
2.4.1 Power Supply........................................................................................ 9
2.4.2 DMX...................................................................................................... 9
3The Menu Field ..................................................................................................... 10
4DMX Channel Selection (DMX Protocol)............................................................. 12
5Maintaining and Cleaning the I
IM
MP
PR
RE
ES
SS
SI
IO
ON
N
X
X4
4S
S............................................... 16
5.1 Safety regulations .......................................................................................... 16
5.2 Maintenance and Interval (rule-of-thumb)...................................................... 16
5.3 Changing the Fuse......................................................................................... 17
6Technical Specifications...................................................................................... 18
7Dimensions ........................................................................................................... 19
8Index...................................................................................................................... 20

GLP
German Light Products GmbH (Instruction version: 1.1) / from software version: V1.09 4
1 Description of Device
1. Moving head (actively and passively
cooled)
2. Arm of device
3. LCD-Display/Menu (data entry)
4. Base with various connectors, air
in/outlets and mounting system
5. Fuse holder
1
2
3
4
5
base side 1
6
7
base side 2
8
9
6. Power On/Off
7. DMX- Output (5-pin)
8. DMX- Input (5-pin)
9. Mains supply (fixed cable)

GLP
German Light Products GmbH (Instruction version: 1.1) / from software version: V1.09 5
1.1 Safety Instructions
The
I
IM
MP
PR
RE
ES
SS
SI
IO
ON
N
X
X4
4S
Ss
s
is a High-Tech Product. To guarantee a
smooth operation, it is necessary to respect the following rules.
The manufacturer of this device will not take responsibility for
damages through any disregard of the information provided in
this manual. Warranty claims also will be voided in the case that
the fixture housing is opened.
1. Before powering on the fixture, make sure that the fixtures fans and air
inlets are clean and not blocked.
2. Ensure that the fixture head can rotate unhindered throughout its complete
range of pan and tilt movement. A safety distance of at least 0.5 m must be
maintained between the fixture and any easily inflammable material (e.g.
decoration material).
3. Attention! Don’t touch the fixture during the operation. This can cause
injuries and/or damages.
4. The fixture doesn’t contain any user serviceable parts. Opening the
fixture will void all warranties.
5. It is necessary to wait at least 15 minutes after disconnecting the mains
power before handling the fixture.. Pay attention to possible hot parts of the
fixture. -- Danger of BURNING --
6. Never look directly into the beam of light or into one of the LEDs.
Never use optical apertures to observe the beam of light. LED Class 2M.
You'll risk serious injury of your eyes and in particular of your retina.
Attention: LED Class 2M can cause injuries of your eyes even
without optical instruments in front of them or within a distance of
less than 0.5m and short exposure time.
Hence: Avoid direct radiation into your eyes!
7. To ensure safe operation, follow also the Installation guide described in
chapter 2. Operating the I
IM
MP
PR
RE
ES
SS
SI
IO
ON
N
X
X4
4S
S
without suitable safety aids like
Safety cables or clamps/hooks can increase the risk of an accident and
must be avoided.
8. Repair, maintenance, and installation work shall be done by qualified or
GLP certified staff only. You need to pay attention to the common rules of
technology that are not explicitly mentioned in this manual.
9. Use only original GLP spare parts. Any structural modification of the system
will terminate all warranty claims.
10. Please keep this instruction manual for future reference.

GLP
German Light Products GmbH (Instruction version: 1.1) / from software version: V1.09 6
2 Preparation and Installation
2.1 Safety information
The I
IM
MP
PR
RE
ES
SS
SI
IO
ON
N
X
X4
4S
Sfixtures from GLP is fitted with a number of plano-
convex lenses in a highly efficient collimator cluster. This type of lens can act as
a strong magnifying glass.
If the rays from a strong light source (such as the sun or another lighting fixture)
are directed towards the front of any of these fixtures, then internal damage
may occur. In a worst case scenario with a high power light source this can
happen very quickly, damaging the fixture internally, potentially melting
components or causing an internal fire within seconds.
In order to avoid these possible problems please adhere to the following
requirements:
• Do not expose the front of a fixture to direct sunlight or any other strong
light sources.
• For outdoor applications during daylight make sure that the front face of
any fixture is either shielded or points away from the sun, even when
fixtures are not in use.
• Do not modify the front glass or lenses of any fixture.
These requirements have to be followed regardless of whether a fixture is
powered on or off as the magnifying effect is an optical effect and therefore
independent from the (electrical) state of the fixture.
Especially when working with high powered b
be
ea
am
m-
-l
li
ig
gh
ht
ts
s; extreme caution and
observance of these safety instructions is mandatory.
Should you have any questions about the operation of your fixture then please
contact your local GLP office, or their authorized distributor, a list of which can
be found at http://www.glp.de.

GLP
German Light Products GmbH (Instruction version: 1.1) / from software version: V1.09 7
2.2 Mounting
The I
IM
MP
PR
RE
ES
SS
SI
IO
ON
N
X
X4
4S
S
is fully operational whether it hangs or is mounted to
the wall. It can also be operated while standing on the floor. Keep a safety
distance of min. 0.5 m towards any easily inflammable materials (decoration
etc.).
Pay attention to the regulations of: BGV C1 (former VBG 70),
DIN VDE 0711-217 and BGI 810-3.
The installation shall be done by qualified staff only.
For the various mounting positions of the I
IM
MP
PR
RE
ES
SS
SI
IO
ON
N
X
X4
4S
S(standing on the
floor, sideways or hanging) different connectors are available. Through this a
safe and firm installation is assured. You'll find dedicated M10 threads on the
bottom side of the fixture
which should be used. In
addition the top of the base
is marked with a FRONT
arrow allowing consistent
orientation during installation.
3x M10
(length max.11mm)
Fixture from below
2xsafetyeyelets
4x rubber feet

GLP
German Light Products GmbH (Instruction version: 1.1) / from software version: V1.09 8
2.2.1 Operating on the Floor (Upright)
The I
IM
MP
PR
RE
ES
SS
SI
IO
ON
N
X
X4
4S
Sis fitted with 4x solid
rubber feet which allows a stable standing of
the fixture. An additional securing is usually not
required. Please pay attention to an even and
gripping surface.
2.2.2 Mounting in hanging position
To operate the I
IM
MP
PR
RE
ES
SS
SI
IO
ON
N
X
X4
4S
Sin a hanging position please use a
half-coupler (clamp). This can be mounted directly to the bottom side of
the fixture. It should be attached centrically with a M10 mm thread bolt
(max. length 11mm).
Attention: Never use a longer bolt as this may damage the interior
of the fixture.
2.2.3 Mounting in sideways Position
To operate the I
IM
MP
PR
RE
ES
SS
SI
IO
ON
N
X
X4
4S
Sin a sideways position please use two
half-couplers (clamps) attached to the bottom side of the base. They
should be attached with M10 mm thread bolts (max. length 11mm).
This technique is necessary to cope with the torque which accrues in this
mounting position. Never use the "Mounting in hanging position"
technique described above to fasten the fixture in the sideways position.

GLP
German Light Products GmbH (Instruction version: 1.1) / from software version: V1.09 9
A safe and sound installation can not be assured in this way. In addition
this can damage the fixture base.
2x half-couplers
1x half-coupler
2.3 Securing the Fixture
Regardless of the mounting method of the I
IM
MP
PR
RE
ES
SS
SI
IO
ON
N
X
X4
4S
S
you'll have to use
a stipulated safety wire. Attach the safety wire through one of the two holes
provided on the base of the fixture and connect it to the primary support
structure. Pay attention to a safe and proper fastening. The safety cable must
comply with BGI 810-3 (EN 60598-2-17 Section 17.6.6) and be capable of
bearing a static suspended load that is ten times the weight of the fixture and all
installed accessories.
2.4 Connections
2.4.1 Power Supply
~100-240 Volt AC, 50-60 Hz, earth contact type plug
Connected load 130 VA (W) <=> T5A (micro-fuse 5x20mm)
Please see printing on the case for the right electronic supply!
Disconnect from the mains supply for changing the fuse and use
only the above described micro-fuse type.
2.4.2 DMX
USITT DMX-512 Standard input/output in 5-pin connectors.
Pin 1 = [Ground] / Pin 2 = [-] / Pin 3 = [+] / Pin 4&5 N.C.
The DMX- Addressing starts at the DMX- Address [001].

GLP
German Light Products GmbH (Instruction version: 1.1) / from software version: V1.09 10
3 The Menu Field
You’ll find the control board on the side part of the arm. It allows you
to make all necessary adjustments of the I
IM
MP
PR
RE
ES
SS
SI
IO
ON
N
X
X4
4S
S.
.With the
Mode-key you get into the main menu. Afterwards you can navigate
through the menu with the Up/Down-keys. Push the Enter-key to get
in the next menu level or to confirm your settings. Make them and set
functions ON/OFF with the Up/Down-keys. Confirm and save it with
the Enter-key (the display shows OK). Push the Mode-key to cancel
the entry and go back to the main menu.
Mode Down
Enter Up
To lock or unlock the keys of the menu field press Mode+Enter+Up simultaneously.
MODE - ENTER
Level1 Level 2 Level 3 Level 4 Remark
DMX Start
Address 001 Set the DMX start address
Special Manual DMX Manual control of all fixture functions
Pan Manual control for Pan (X-movement)
Pattern
Byte 1 Manual control for Pattern Byte 1 LED 1 - 7
Pattern Manual control for Pattern channel / bank
Zoom Manual control for Zoom
Speed
Movements Manual control for Pan/Tilt movements
Pan/Tilt
Movements Manual control for Pan/Tilt movements
Special
White
Temperature
Manual control for Color temperature
Dimmer Manual control for Dimmer
Shutter Manual control for Shutter
White Manual control for White
DOWN - UP
Blue Manual control for blue
Green Manual control for green
Red Manual control for red
Color Wheel Manual control for the color wheel
Tilt Manual control for Tilt (Y-movement)
Adjust
Key code
xxxx Use the code for entering the calibration menu
(for authorized persons only)
Display
Contrast Adjustment for the Display contrast
PWM -
Frequ. Adj. Changes PMW frequency
Pan Offset Calibration for Pan-Offset
Tilt Offset Calibration for Tilt-Offset
LED adjust
White adjust
red Adjust intensity for red channel
White adjust
blue Adjust intensity for blue channel
White adjust
green Adjust intensity for green channel
Clear
EEPROM Erase EEPROM memory

GLP
German Light Products GmbH (Instruction version: 1.1) / from software version: V1.09 11
Diagnose Diagnose fixture functions
DMX Image
Set image if
DMX off Activates a stored scene if DMX is off
Save image
in memory Stores the scene currently sent to the unit
DMX input
Monitor Indicates the presently received DMX signal per
DMX channel
Pan Instantaneous value for Pan
Tilt Instantaneous value for Tilt
Pattern
Byte 1 Instantaneous value for Pattern Byte 1
Pattern Instantaneous value for Pattern channel / bank
Zoom Instantaneous value for Zoom
Speed
Movements Speed adjustment for Pan/Tilt movements
see item below
Pan/Tilt
Movements Instantaneous value for Pan/Tilt movements
Special Instantaneous value for Special
White
Temperature
Adjustment of the color temperature for WHITE
Dimmer Instantaneous value for Dimmer
Shutter Instantaneous value for Shutter
White Instantaneous value for White
Blue Instantaneous value for Blue
Green Instantaneous value for Green
Red Instantaneous value for Red
Color Wheel Instantaneous value for Color Mixing unit
Set DMX
Mode Select the desired DMX Mode
Compressed
Mode Fixture works in "Compressed" mode
see also
section 4 below
Normal
Mode Fixture works in "Normal" mode
see also
section 4 below
DOWN - UP
High-Res.
Mode Fixture works in "High Resolution" mode
see
also section 4 below
Position
feedback Switch automatic position feedback ON/OFF
Reverse Pan Invert Pan movements: ON/OFF
Reverse Tilt Invert Tilt movements: ON/OFF
Reset RESET and new calibration for all functions

GLP
German Light Products GmbH (Instruction version: 1.1) / from software version: V1.09 12
4 DMX Channel Selection (DMX Protocol)
Normal-Mode 18 DMX channels
Channel Function Time and Value DMX HEX %
1) PAN-
coarse 0..255 00..FF 0..100
2) PAN-fine 0..255 00..FF 0..100
3) Tilt-
coarse 0..255 00..FF 0..100
4) Tilt-fine 0..255 00..FF 0..100
5) Color Colors adjustable via RGB 0..7 00..07 0..2..5
(fixed) Color 01 - Red 1) 8..15 08..0F 3..5.5
Color 02 - Amber 1) 16..23 10..17 6..8.5
Color 03 - Warm Yellow 1) 24..31 18..1F 9..12.5
Color 04 - Yellow 1) 32..39 20..27 13..15.5
Color 05 - Green 1) 40..47 28..2F 16..18.5
Color 06 - Turquoise 1) 48..55 30..37 19..21.5
Color 07 - Cyan 1) 56..63 38..3F 22..24.5
Color 08 - Blue 1) 64..71 40..47 25..27.5
Color 09 - Lavender 1) 72..79 48..4F 28..30.5
Color 10 - Malve 1) 80..87 50..57 31..34.5
Color 11 - Magenta 1) 88..95 58..5F 35..37.5
Color 12 - Pink 1) 96..103 60..67 38..40.5
White - CTO 3200K 104..111
68..6F 41..43.5
White 5600K 112..119
70..77 44..46.5
White - CTB 7200K 120..127
78..7F 47..49.5
Rainbow Effect Stop 2) 128 80 50
Rainbow Effect
3) slow - fast 129..223
81..DF 51..88
Random colors slow - fast 224..255
E0..FF 89..100
6) Red Color mixing system - Red 0 - 100% 0..255 00..FF 0..100
7) Green Color mixing system - Green 0 - 100% 0..255 00..FF 0..100
8) Blue Color mixing system - Blue 0 - 100% 0..255 00..FF 0..100
9) White Color mixing system - White 0 - 100% 0..255 00..FF 0..100
10) Shutter Shutter closed 0..15 00..0F 0..5.5
Shutter pulse random slow – fast 16..47 10..2F 6..18.5
Up-dimming then Shutter closing
(random patterns) slow – fast 48..79 30..4F 19..31
Shutter open then down-dimming
(random patterns) slow – fast 80..111 50..6F 32..43
Up-dimming then down-dimming
(random patterns) slow – fast 112..143
70..8F 44..56
Strobe effect pause 5s - 0.1s 160..199
A0..C7 63..77
Strobe effect slow - fast 1 Hz - 10 Hz 200..239
C8..EF
78..94
Shutter open 240..255
F0..FF 95..100
11) Dimmer Dimmer 0 - 100% 0..255 0..FF 0..100
12) CTO No CTO 0..7 0..07 0..2.5
Continuous color temperature
correction Applicable for ALL
colors 8..255 08..FF 3..100
13) Special Pattern Block 1
channel 17 0..3 00..03 0..1
Change PWM frequency 100..200
64..C8 40..78
RESET 250..255
FA..FF 98..100
14) Move- No macros 0 00 0
ment Movement Size Phase Use "Speed" to adjust
macros PAN 1 0° 01..01 01..01 0.5

GLP
German Light Products GmbH (Instruction version: 1.1) / from software version: V1.09 13
Channel Function Time and Value DMX HEX %
1 90° 02..03 02..03 1.0
1 180° 04..05 04..05 1.7
1 270° 06..07 06..07 2.5
PAN 2 0° 08..09 08..09 3.3
2 90° 10..11 0A..0B 4.1
2 180° 12..13 0C..0D
4.9
2 270° 14..15 0E..0F 5.7
PAN 3 0° 16..17 11..11 6.5
3 90° 18..19 12..13 7.3
3 180° 20..21 14..15 8.0
3 270° 22..23 16..17 8.8
PAN 4 0° 24..25 18..19 9.6
4 90° 26..27 1A..1B 10.4
4 180° 28..29 1C..1D
11.2
4 270° 30..31 1E..1F 12
TILT size / phase see PAN 32..63 20..3F 13..25
PAN / TILT size / phase see PAN 64..95 40..5F 26..37
PAN / TILT (inverse) size / phase see PAN 96..127 60..7F 38..50
Circle size / phase see PAN 128..159
80..9F 51..62
Circle (inverse) size / phase see PAN 160..191
A0..BF 63..75
Lying eight size / phase see PAN 192..223
C0..DF
76..87
Random movement size / phase see PAN 224..255
E0..FF 88..100
15) Speed Pan/Tilt movement speed from
controller 0..1 00..01 0..0..5
Pan/Tilt Pan/Tilt, slow – fast
Use this channel also for the speed of
the movements (channel 14).
02..255 02..FF 1..100
16) Zoom Wide - narrow (spot) 0…255 00…FF
0…100
17) Pattern No pattern 0..2 00..02 0..1
Pre-defined patterns 03..253 03..FD 2..99
Activates direct access to LED Pattern 254..255
FE..FF 100
18) Pattern
Byte 1 Direct access to Pattern of LED 1..7 0…255 00…FF
0…100
Compress-Mode 14 DMX channels
Channel Function Time and Value DMX HEX %
1) PAN-
coarse 0..255 00..FF 0..100
2) PAN-fine 0..255 00..FF 0..100
3) Tilt-
coarse 0..255 00..FF 0..100
4) Tilt-fine 0..255 00..FF 0..100
5) Color Colors adjustable via RGB 0..7 00..07 0..2.5
(fixed) Color 01 - Red 1) 8..15 08..0F 3..5.5
Color 02 - Amber 1) 16..23 10..17 6..8.5
Color 03 - Warm Yellow 1) 24..31 18..1F 9..12.5
Color 04 - Yellow 1) 32..39 20..27 13..15.5
Color 05 - Green 1) 40..47 28..2F 16..18.5
Color 06 - Turquoise 1) 48..55 30..37 19..21.5
Color 07 - Cyan 1) 56..63 38..3F 22..24.5
Color 08 - Blue 1) 64..71 40..47 25..27.5

GLP
German Light Products GmbH (Instruction version: 1.1) / from software version: V1.09 14
Channel Function Time and Value DMX HEX %
Color 09 - Lavender 1) 72..79 48..4F 28..30.5
Color 10 - Mauve 1) 80..87 50..57 31..34.5
Color 11 - Magenta 1) 88..95 58..5F 35..37.5
Color 12 - Pink 1) 96..103 60..67 38..40.5
White - CTO Color temperature
3200K 104..111
68..6F 41..43.5
White Color temperature
5600K 112..119
70..77 44..46.5
White - CTB Color temperature
7200K 120..127
78..7F 47..49.5
Rainbow Effect Stop 2) 128 80 50
Rainbow Effect
3) slow - fast 129..223
81..DF 51..88
Rainbow Effect, random colors slow - fast 224.255 E0..FF 89..100
6) Red Color mixing system - Red 0 - 100% 0..255 00..FF 0..100
7) Green Color mixing system - Green 0 - 100% 0..255 00..FF 0..100
8) Blue Color mixing system - Blue 0 - 100% 0..255 00..FF 0..100
9) White Color mixing system - White 0 - 100% 0..255 00..FF 0..100
10) Shutter Shutter closed 0..15 00..0F 0..5.5
Random Pulse effect slow - fast 16..47 10..2F 6..18.5
Up-dimming then Shutter closing
(random patterns) slow - fast 48..79 30..4F 19..31.5
Shutter open then down-dimming
(random patterns) slow - fast 80..111 50..6F 32..43
Up-dimming then down-dimming
(random patterns) slow - fast 112..143
70..8F 44..56
Strobe effect pause 5s .. 1s 144..199
A0..C7 57..77
Strobe effect, slow - fast 1 Hz .. 10 Hz 200.239 C8..EF
78..94
Shutter open 240...249
F0..F9 95..97.5
Shutter open 251..255
FB..FF 99..100
11) Dimmer Dimmer 0 - 100% 0..255 0..FF 0..100
12) Zoom Wide - narrow (spot) 0…255 00…FF
0…100
13) Special Pattern Block 1
channel 14 0..3 00..03 0..1
Change PWM frequency 100..200
64..C8 40..78
RESET 250..255
FA..FF 98..100
14) Pattern No pattern 0..2 00..02 0..1
Pre-defined patterns 03..253 03..FD 2..99
High Resolution (Extended) -Mode 19 DMX Channels
Channel Function Time and Value DMX HEX %
1) PAN-
coarse 0..255 00..FF 0..100
2) PAN-fine 0..255 00..FF 0..100
3) Tilt-
coarse 0..255 00..FF 0..100
4) Tilt-fine 0..255 00..FF 0..100
5) Red-
coarse Color mixing system – Red 0 - 100% 0..255 00..FF 0..100
6) Red-
fine Color mixing system – Red-Low 0..255 00..FF 0..100

GLP
German Light Products GmbH (Instruction version: 1.1) / from software version: V1.09 15
Channel Function Time and Value DMX HEX %
7) Green-
coarse Color mixing system – Green 0 - 100% 0..255 00..FF 0..100
8) Green-
fine Color mixing system – Green-Low 0..255 00..FF 0..100
9) Blue-
coarse Color mixing system – Blue 0 - 100% 0..255 00..FF 0..100
10) Blue-
fine Color mixing system – Blue-Low 0..255 00..FF 0..100
11) White-
coarse Color mixing system – White 0 - 100% 0..255 00..FF 0..100
12) White-
fine Color mixing system – White-Low 0..255 00..FF 0..100
13) Shutter Shutter closed 0..15 00..0F 0..5.5
Random Pulse effect slow - fast 16..47 10..2F 6..18.5
Up-dimming then Shutter closing
(random patterns) slow - fast 48..79 30..4F 19..31.5
Shutter open then down-dimming
(random patterns) slow - fast 80..111 50..6F 32..43
Up-dimming then down-dimming
(random patterns) slow - fast 112..143
70..8F 44..56
Strobe effect pause 5s - 1s 144..199
A0..C7 57..77
Strobe effect, slow - fast 1 Hz - 10 Hz 200..239
C8..EF
78..94
Shutter open 240...249
F0..F9 95..97.5
Shutter open 251..255
FB..FF 99..100
14) Dimmer-
coarse Dimmer 0 - 100% 0..255 0..FF 0..100
15) Dimmer-
fine Dimmer - Low 0..255 0..FF 0..100
16) Zoom Spot - Flood 0…255 00…FF
0…100
17) Special Pattern Block 1
channel 18 0..3 00..03 0..1
Change PWM frequency 100..200
64..C8 40..78
RESET 250..255
FA..FF 98..100
18) Pattern No pattern 0..2 00..02 0..1
Pre-defined patterns 03..253 03..FD 2..99
Activates direct access to LED Pattern
254..255
FE..FF 100
19) Pattern
Byte 1 Direct access to Pattern of LED 1..7 0…255 00…FF
0…100
1) The predefined colors can be used as start-colors for the Rainbow effect. Please select first a
desired start-color before you activate the rainbow effect. All I
IM
MP
PR
RE
ES
SS
SI
IO
ON
N
X
X4
4S
Swill then start from
that color and will execute the rainbow effect synchronously. Different I
IM
MP
PR
RE
ES
SS
SI
IO
ON
N
X
X4
4S
Scan have
different start-colors but will still execute the rainbow effect synchronously. If you choose a color
different from the ones marked with 1) in the tables above the rainbow start-color will be red.
2) Rainbow-effect Stop will pause this function. After resuming the rainbow-effect will be continued
from the current color.
3) The Rainbow-effect will run synchronously only if started from one of the predefined colors (see also
1) before).

GLP
German Light Products GmbH (Instruction version: 1.1) / from software version: V1.09 16
Locking and unlocking the Control Panel
Please lock and unlock the control panel by pressing the menu keys MODE & ENTER & UP at the
same time.
Additional Display Indications
As a default you'll find the following additional information in the first row of the LCD display:
Vxx/xx/xx/xx/x (e.g. V1.09/10/16/NN/NS)
NS ( DMX Mode = Normal / Dimmer Mode = Soft)
NN ( Pan Mode =Normal; Tilt Mode = Normal)
16 = Pan/ Tilt Driver Version
10 LED driver version
1 09 Main CPU version
5
5
Maintaining and Cleaning the I
IM
MP
PR
RE
ES
SS
SI
IO
ON
N
X
X4
4S
S
The I
IM
MP
PR
RE
ES
SS
SI
IO
ON
N
X
X4
4S
Sis a fixture of very low maintenance. It is only necessary to
clean the air inlets and outlets as well as the optical LED lenses from time to time.
For safe operation it is absolutely essential that the fixture is kept clean and that dust,
dirt and smoke-fluid residues must not build up on, or within the fixture. Otherwise the
fixture's light-output will be significantly reduced or damages can occur. Regular
cleaning will not only ensure the maximum light-output, but will also allow the fixture
to operate reliably throughout its life.
A soft lint-free cloth moistened with any good glass cleaning fluid is recom-
mended, under no circumstances should alcohol or solvents be used!
5.1 Safety regulations
• Pull out the mains power plug!
• Wait min. 15 minutes after disconnecting power to allow the fixture to cool
down.
5.2 Maintenance and Interval (rule-of-thumb)
The contamination of the fixture depends on the environment details. Hence no
general guidelines can be given. The intervals given below are only suggestions
from our experience.
Position Interval In this way
LED reflector and optical system weekly soft brush /lint-free cloth
Fan and air channel monthly vacuum cleaner, airbrush, etc.

GLP
German Light Products GmbH (Instruction version: 1.1) / from software version: V1.09 17
Attention:
• Never let optical parts come into contact with oil or fat.
• Before running the fixture wait until all parts are dry.
• Never tough lenses with bare fingers.
5.3 Changing the Fuse
Follow the safety regulations as described above!
The micro-fuse holder (2) is located on the topside of the base. In order to attain
access you first need to remove one of the two plastic side covers of the fixture
arm. Open the two screws no. 1 shown in the picture below.
Replace the fuse with one with the exact rating as printed in this manual or the
body of the fixture. Never use a different one!
Attach the side cover again before operating the fixture.
1
1
2
2

GLP
German Light Products GmbH (Instruction version: 1.1) / from software version: V1.09 18
6 Technical Specifications
Power supply
Power consumption 130 VA (Watt)
Power Input ~100-240 V AC, 50-60 Hz (wide range input)
Fuse protection Micro-fuse 5x20 mm, T5A
Operational Parameters
Max. Ambient
Temperature 5° - 45°C (integrated overheating switch)
Mounting Position Any (see relevant chapter)
Lighting System - Additive Color mixing
LED Type 7 x Osram Ostar RGBW multi-chip
Lifetime 50,000 h
Wavelength optimized for maximum presentable color space
Optical System
Full RGBW / High efficient Collimator cluster
Shutter / Dimmer (8/16 Bit)
Strobe- Effect with variable speed between 1 - 10 flashes per second, Random-Strobe, Pulse-
Effects
Continuous Dimmer 0 - 100%
Zoom
7 to 50 degree continuous zoom
Optical Patterns
Several hundred pre-defined beam patterns with direct access and manipulation
DMX Control
Standard USITT DMX-512, 5-pin XLR; [+] = Pin 3 / [-] = Pin 2 / [Ground] = Pin 1 / Pin 4&5 N.C.
Die DMX- Addressing starts at the DMX channel [001].
Pan / Tilt (8/16 Bit)
Pan- movement 660° in min. 3,2 seconds (Position Feedback)
Tilt- movement 300° in min. 1,5 seconds (Position Feedback)
Weights and Measures
Base only ∅165,5 mm
Total width of fixture 224 mm
Hight (head vertical) 323mm (incl. base)
Weight (net) 5.5 kg

GLP
German Light Products GmbH (Instruction version: 1.1) / from software version: V1.09 19
7 Dimensions
3xM10
(length max.11mm)

GLP
German Light Products GmbH (Instruction version: 1.1) / from software version: V1.09 20
8 Index
B
b
be
ea
am
m-
-l
li
ig
gh
ht
ts
s.................................................. 6
BGV C1 ........................................................ 7
C
Cleaning...................................................... 16
Compress-Mode........................................ 13
D
Danger of BURNING.................................... 5
Description of Device .................................... 4
Dimensions................................................. 19
DIN VDE 0711-217 ....................................... 7
Display Indications ................................ 16
DMX ............................................................. 9
E
e-mail............................................................ 1
EN 60598-2-17.............................................. 9
Enter-key.................................................. 10
H
High Resolution (Extended) -Mode........... 14
I
Instruction Version........................................ 1
Internet ......................................................... 1
L
LED Class 2M.............................................. 5
M
Maintenance ............................................... 16
Menu Field.................................................. 10
Micro-fuse..................................................... 9
Mode-key.................................................. 10
Mounting...................................................... 7
Mounting in hanging Position......................... 8
Mounting in sidewise Position........................ 8
Mounting on the Floor ................................... 8
N
Normal-Mode............................................. 12
O
Optical parts.............................................. 17
P
Pan- Movement........................................... 18
plano-convex lenses...................................... 6
Power Supply.............................................. 9
R
RESET........................................................ 12
S
Safety distance ............................................. 7
Safety information......................................... 6
Safety Instructions......................................... 5
Secure the Device ....................................... 9
Software Version...........................................1
sunlight ......................................................... 6
T
Technical Specifications........................... 18
Tilt- Movement............................................ 18
U
Up/Down-keys.......................................... 10
V
VBG 70......................................................... 7
W
Warranty claims ............................................ 5
Weights and Measures................................ 18
Table of contents
Other German Light Products Lighting Equipment manuals
Popular Lighting Equipment manuals by other brands

Simon
Simon LEDFLEX 810 quick guide

Luminaire led
Luminaire led LVP751 installation guide

iGuzzini
iGuzzini 6677 instruction sheet

HERA
HERA SWORD SINGLE COLOR Radius Diffused User manual & installation guide

Konyks
Konyks Antalya White E27 quick start

PureEdge Lighting
PureEdge Lighting Piston installation instructions