Ghost Controls DTP1 Installation instructions

DTP1 GATE OPENER INSTALLATION AND OWNERS MANUAL
5004019
CONFORMS TO UL STD 325
A 12V BATTERY IS REQUIRED TO OPERATE OPENER AND IS INCLUDED!
*If using solar you will need to add another 12V Battery to your Battery Box Kit.
201812 DTP1IM
WARNING: This product can expose you to chemicals including lead, which is known to the
State of California to cause cancer. For more information, go to www.P65Warnings.ca.gov

CONTACT US:
1572 Capital Circle NW, Tallahassee, FL 32303
www.ghostcontrols.com
For sales, product information, or to locate a retailer near you:
Call: 850-558-5520
Monday through Friday: 8:00–5:00 EST
For installation assistance and technical support:
Call: 850-898-1411
Monday through Friday: 8:00–5:30 EST
Product information, technical article, and installation videos can be found at:
myghostcontrols.force.com/Support/s or
Ghostcontrols.com/Support/Installation-Video
©Ghost Controls 2018

CONTENTS
Installation and Owners Manual
Warranty Registration page 5
Operator Specifications page 7
System Safety page 9
System Overview page 13
Installation Planning page 15
Tools Needed page 19
Included Parts page 20
PULLTOOPEN INSTALLATION page 21
Control Box Installation page 26
Battery Installation page 26
Connecting Arm to Control Box page 28
Setup System Controller page 29
Front Mount Gate Bracket Installation page 32
Setting the Closed Limit page 36
Powering the System AC page 37
Powering the System Solar page 38
Setting the Auto Close Feature page 39
PUSHTOOPEN INSTALLATION page 41
Control Box Installation page 46
Battery Installation page 46
Connecting Arm to Control Box page 48
Setup System Controller page 49
Front Mount Gate Bracket Installation page 52
Setting the Open Limit page 56
Powering the System AC page 57
Powering the System Solar page 58
Setting the Auto Close Feature page 59
Troubleshooting page 61
Connecting Optional Accessories page 63
Manual Gate Operation page 65
Accessories page 66
3
CONTENTS

BEFORE YOU BEGIN:
■A 12 volt automotive/marine battery or Ghost Controls ABBT Battery Box Kit is required to power the operator.
■Push-To-Open applications (gate that swings away from the property) will require the Ghost Controls push-to-open
bracket kit (AXPO).
■If charging your system with the AC transformer, you will need to purchase a 16 gauge stranded low voltage wire to
connect the transformer to the gate operator control board. Up to 1,000 ft. of wire can be used.
■For installations farther than 1,000 ft. from an AC power source, the Ghost Controls 10 Watt Solar Panel Kit (AXDP)
can be used to charge the battery. Up to 30 Watts of solar power can be used.
CUSTOMIZING YOUR GATE:
Information on additional accessories shown below can be found on the accessory page 66 or visit
www.ghostcontrols.com
INCLUDED IN DTP1 AND DEP2 KITS
ADDITIONAL ACCESSORIES
12V battery required and included
Opens gates up to 20 ft. or 1,000 lbs.
per gate leaf
Low Voltage Wire
(AXLV)
Wireless
Keypad (AXWK)
used for exit
of property
Safety Placards
DTP1 or DEP2
Operator Arm
5 Button
Transmitter
(AXP1)
3 Button
Transmitter
(AXS1)
4DTP1 SINGLE KIT
©Ghost Controls 2018

PROTECT YOUR INVESTMENT!
Get An Additional 6 Months Warranty when you register
your product(s) at ghostcontrols.com.
WARRANTY
REGISTER ONLINE WWW.GHOSTCONTROLS.COM
NOTE
If your unable to access the internet please fill out the warranty form below and mail in to us at Ghost Controls
1572 Capital Circle NW, Tallahassee, FL 32303
First Name:__________________________________________ Last Name: _________________________________
Street:___________________________________________________________ Apt. #: ___________________________
City : __________________________________________ State:_________________________ Zip: _______________
Phone Number: ___________________________________ Email Address: _________________________________
Items Purchased:
DTP1
DEP2
Where did you buy your gate opener system? (please include a copy of your receipt)
Type of gate you are using?
Chainlink Ornamental Tube Vinyl
Approximate Gate Weight:___________________ pounds per leaf
Approximate Gate Length:___________________ feet per leaf
Type of Application:
Farm Home Business
Item Serial Number:___________________ Item Serial Number: ___________________ Manufacturer Date:__________________
Did you purchase any accessories? (Please list below)
5
DTP1 SINGLE KIT
©Ghost Controls 2018

6BLANK PAGE

7
SPECIFICATIONS
©Ghost Controls 2018
SPECIFICATIONS
■Compliance: The operator is system certified to be in compliance
with UL325 Standard, 7th Edition
■System Operating Voltage: 12 VDC
■System Battery Type: Battery Box Kit (ABBT) included
■System Current: 1-2 Amps is typical when active.
Standby is 20 milliamps
■Operator Arm Maximum Stroke Distance: 23"
■Maximum Gate Length: 20'
■Operator Opening Speed: 90 degrees in approximately 15 seconds
■Maximum Operator Opening Range: 110 degrees
■Linear Actuator Operating Temperature: -5°F to 160°F
Maximum Gate
Length and
Weight
Max
900 lbs.
800 lbs.
700 lbs.
600 lbs.
500 lbs.
400 lbs.
350 lbs.
325 lbs.
300 lbs.
5' 6' 8' 10' 12' 14' 16' 18' 20'
DTP1 DTP1
DTP1
DTP1
DTP1
DTP1
DTP1
DTP1
DTP1
1000 lbs.
SPECIFICATIONS
DTP1 GATE OPERATOR KIT

8BLANK PAGE
©Ghost Controls 2018

9
SYSTEM SAFETY
©Ghost Controls 2018
This manual contains important safety precautions and
warnings for both the installer and end users or consumers
of this automatic gate opener system. The following warn-
ings and safety are intended to apply to the most common
applications but may not apply to all possible installation
and applications for these products. To reduce risk of
injury or death:
I. Carefully read and follow all safety precautions,
warnings, installation and operating instructions.
II. DO NOT ALLOW CHILDREN TO OPERATE
GATE CONTROLS. Do not allow children or pets
to play near the gate opener system. Keep all gate
control accessories such as remote transmitters,
keypads, and push buttons out of reach of children
and store in a secure area when not in use.
III. Understand how to disconnect the power and
manually open the gate (beginning on page 65)
BEFORE you begin using the gate opener system.
If you are unsure of any of these steps, please con-
tact GHOST CONTROLS®Technical Support at
850-898-1411 or online at https://myghostcontrols.
force.com/Support/s.
IV. Disconnect the gate operator from the gate only
when the gate is not in motion and the opener
system is turned o.
V. Moving gates can be dangerous. No one, including
people or animals, should cross the path of a moving
gate. Maintain a safe distance from moving parts
and avoid any areas where hands or fingers could
be pinched.
VI. Become familiar with potential entrapment zones as
shown below and avoid these areas when the gate is
turned on.
VII. The gate opener system must be installed only
in applications that it is specifically designed for
including: frequency of use, length, and weight
of the gate.
VIII. Install the gate operator system on the inside of
the property, gate, or fence line to prevent public
access to it. Most applications are installed in a pull-
to-open configuration so that the gate opens into
the property and away from any public roads.
IX. The control board for the gate operator system
should be protected from unauthorized access
inside the control box to prevent tampering or
adjustments to its setting once installed. The
control box is designed so that a padlock can be
attached to keep the box securely closed. An
accessory Clevis Pin (AXCL) is available for
purchase to secure the operator(s) to the gate
with a padlock.
X. Keypads and push-buttons to activate the gate
operator system must be a minimum of 10'away
IN DIRECT LINE OF SIGHT VISIBILITY TO
THE GATE so that the user can verify that any
potential entrapment areas are clear of potential
obstructions.
XI. The included warning signs must be attached to
each side of the gate to alert the public of the
automatic gate operator system. Please contact
GHOST CONTROLS®Technical Support for
replacement signs if yours become damaged.
XII.While the gate is moving do not drive into the gate
area to prevent entrapment and potential damage
to your vehicle, gate, AND the gate opener system.
XIII. Do not attempt to “race the gate” by driving
through the gate while it is opening or closing. This is
extremely dangerous and can cause damage to your
vehicle, gate, AND the gate opener system.
XIV.Maintain the gate and the gate opener system to
make sure that the gate continues to swing freely
and is level throughout the entire swing path.
The gate hinges should be lubricated regularly,
the condition of the battery checked every few
months, and all connections checked no less than
an annual basis.
XV. In the event that you sell the gate opener system
or your property with a system installed, please
provide these instructions to the new owners. The
most recent version of these instructions can be
found on our support website at https://myghost-
controls.force.com/Support/s.
SYSTEM SAFETY
GATE OPENER SYSTEMS

10 SYSTEM SAFETY
©Ghost Controls 2018
VEHICULAR GATE STANDARD
We recommend that all vehicular gates be constructed
and installed in accordance with Active Standard ASTM
F2200, Standard Specification for Automated Vehicular
Gate Construction. For more information on this standard,
contact ASTM directly at http://www.astm.org/Standards/
F2200.htm.
WARNING SIGNS
The included warning signs must be installed on both the
inside and outside of the gate.
! !
©GHOST CONTROLS 2016
1. Persons are to keep clear! The gate is able
to be moved without prior warning.
2. DO NOT let children operate the gare or
play in the gate area.
3. Persons are to operate the gate only when
the gate area is in sight and free of people
and obstructions.
4. Persons are to read the user’s manual and
safety instructions.
WARNING
ALARM
Your GHOST CONTROLS®Gate Operator system
includes an audible alarm. This alarm will continue to
sound for 5 minutes when two sequential obstructions
are detected during gate travel per UL325 safety
standards or until one of the following occurs:
■The gate operator receives an intended signal from a
hard wired entry/exit source such as a push button or
a wired keypad. Note that wireless transmitters and
wireless keypads cannot deactivate the alarm.
■The gate operator system is powered o and then on
again at the main power switch in the control box.
NOTE
The alarm may also be used as audio feedback for other
modes of operation under normal operation.
SWING GATE PROTECTION AND
ENTRAPMENT ZONES
As specified in Gate Operator Safety Standard, UL325
(30A 1.1) 7th Edition, all gate operators must include
two independent means of entrapment protection. All
GHOST CONTROLS®Automatic Gate opener systems
meet this standard as indicated on the product packaging
through the following:
1. TYPE A Inherent.
2. Number one above AND either of the following two
options:
A. TYPE C Inherent force limiting.
B. TYPE B1 and B2 monitored contact and non-
contact sensors.
If you have questions about compatibility of third
party safety devices, please contact GHOST
CONTROLS®technical support for assistance
at https://myghostcontrols.force.com/Support/s.
Refer to the monitored photo eye instructions for proper
placement of the sensors. Proper installation of these
sensors is critical to avoid false tripping while gate is in
motion and to reduce potential entrapment.
CAUTION
Extreme caution must be exercised when automatic
gate opener system is in operation, regardless of which
safety systems are installed and in use.

11
SYSTEM SAFETY
©Ghost Controls 2018
Grey Indicates Potential
Entrapement Areas
OPTIONALPHOTO BEAM
OPTIONAL PHOTO BEAM
OPTIONAL PHOTO BEAM
OPTIONAL PHOTO BEAM
OPTIONAL PHOTO BEAM
OPTIONAL
PHOTO BEAM
ENTRAPMENT AREA NOTES
Between gate and post Keep hands, feet, and pets away from this area when gate is in motion.
Pinch point between opener and gate Keep hands, feet, and pets away from this area when gate is in motion.
Path of the moving gate All one zone
Leading edge of gate and pinch point
between gates in a dual gate installation
The leading edge of the gate in motion can easily cause injury to
people, pets, or livestock, and will damage property including
vehicles if it comes into contact with them.

12 BLANK PAGE
©Ghost Controls 2018

13
SYSTEM OVERVIEW
©Ghost Controls 2018
1. This gate operator is only intended for use on gates
intended for vehicular access and is not intended for
pedestrian gate applications. Pedestrians must use a
separate entrance.
2. The GHOST CONTROLS®Automatic Gate Opener
can be installed on a pull-to-open application with the
items included in the kit. For push-to-open applica-
tions you will need to purchase the required Push-To-
Open (item AXPO) bracket kit from your local retailer
or visit https://www.ghostcontrols.com/shop or contact
GHOST CONTROLS®Sales at 850-558-5520 to
purchase.
3. This GHOST CONTROLS®Automatic Gate Opener
features a patent-pending SafeForce®power limiting
feature that doesn’t require Photo Eyes for entrapment
protection in most applications of a properly installed
gate. During installation, you may instead choose to use
external monitored safety devices such as non-contact
photo eyes (item AXPE sold separately) and will need
to enable this setting on the main system controller
during setup.
. The operator can be used on a variety of gate types,
but CAN NOT BE USED ON SOLID OR WOOD
PANEL GATES. Solid panel gates have a higher
resistance to wind and may result in damage to the
automatic gate operator.
5. All GHOST CONTROLS®Automatic Gate Operators
include automatic reversing safety features that will
make the gates stop and reverse direction within 2 sec-
onds of encountering an obstruction. There is a manual
setting on the main gate operator control board labeled
Force Setting that adjusts the sensitivity of this feature.
6. This GHOST CONTROLS®Automatic Gate
Operator can be enhanced with additional GHOST
CONTROLS®accessories such as our remote
transmitters, keypads, and all other accessories,
sold separately. (Accessories see page 66). The
GHOST CONTROLS®technical support team is
happy to assist in verifying compatibility of any products
not oered by GHOST CONTROLS®. For additional
assistance, please contact GHOST CONTROLS®
Technical support https://myghostcontrols.force.com/
Support/s or by calling 850-898-1411.
7. Check all local building codes and ordinances prior to
installing this automatic gate operator system to make
sure your planned installation is in compliance.
8. Your gate must be in good working condition before
installation of the automatic gate operator system and
meet the following criteria:
A. GATE CAN NOT USE WHEELS for support or
drag along the ground at any point in the opening
or closing cycle.
B. GATE SHOULD BE LEVEL, PLUMB, AND
MOVE FREELY IN BOTH DIRECTIONS
WHEN MINIMAL FORCE IS APPLIED IN
THE OPENING OR CLOSING DIRECTION.
C. Gate should NOT open uphill or downhill.
9. The vehicular entry gate system must be installed
in a location that prevents entrapment by providing
sucient clearance between it and adjacent structures
when opening and closing.
SYSTEM OVERVIEW
IMPORTANT INSTRUCTIONS
Thank you for choosing a GHOST CONTROLS®Automatic Gate Opener system, the most innovative gate opener systems
available for residential applications on the market today. This manual will guide you through the proper installation and main-
tenance methods. To reduce the risk of injury or death: READ, UNDERSTAND, AND FOLLOW ALL INSTRUCTIONS
CAREFULLY AND COMPLETELY. Following these directions is critical to a successful and safe operating environment.

14 SYSTEM OVERVIEW
©Ghost Controls 2018
10. When planning a system that will allow entry from a
busy road or highway, make sure the system is placed
far enough from the road to prevent trac congestion.
11. Swing gate systems must not open into public access
areas or into the road which could cause collision with
a moving vehicle.
12. Test the gate operator monthly. The gate MUST
reverse on contact with a rigid object or stop when
an object activates the non-contact sensors. After
adjusting the force or the limit of travel, retest the gate
operator. Failure to adjust and retest the gate operator
properly can increase the risk of injury or death.
13. SEPARATE PEDESTRIAN GATE IS REQUIRED!
14. Single or dual gate operation based on the size of your
opening, gate specifications, and operator system
capacities.
A. Dual gate operations require trenching across the
driveway so that the power cable for the second-
ary gate operator can be buried.
B. The power cable should always be enclosed
in PVC conduit for protection, including
when buried across the driveway in dual gate
applications.
15. Swing direction of gate(s). The image (shown in dia-
gram below) indicates the more common “Pull-to-
Open” installation and the less common “Push-to-
Open” installation.
16. Vehicle Sensors should NOT be used on properties
that contain livestock or animals.
17. SAVE THESE INSTRUCTIONS.

15
PLANNING
©Ghost Controls 2018
INSTALLATION VIDEO CAN BE FOUND AT GhostControls.com/Support/Installation-Video
PREPARE THE GATE
Proper installation, care, and ongoing maintenance of the gate is critical to increased usage life of the automatic gate operator
system. The following items should be considered and addressed if needed PRIOR to installation of the automatic gate
operator system:
1. The gate must swing freely throughout its entire range of motion (fully open to fully closed) remaining plumb and level. The
gate should not swing uphill or downhill when opening or closing.
2. The gate must not drag on the ground at any point during its motion and MUST NOT BE SUPPORTED BY
ROLLERS OR WHEELS.
3. Extremely heavy gates that exceed 200 lbs in weight per leaf should be mounted with ball bearing hinges that include
grease fittings.
4. The gate should be mounted to a very stable post or column that is secured in the ground with concrete. Securing the post
with concrete reduces the twisting eect that the torque of the gate places on the mounting post/column when moving
through its range of motion. Installation is not recommended on any post or column that is not installed in the ground with
concrete.
5. The front mount of the gate operator should be attached to the gate securely. This may require modifications to the gate
design or surface to maintain this secure mounting location.
6. The gate must be plumb, level, and swing freely with minimum eort in both the open and closed directions without
hindrance.
LEVEL
CONCRETE THE POSTS
IN THE GROUND
INSTALLATION PLANNING
SITE PLANNING SITE

16 PLANNING
©Ghost Controls 2018
NOTE
Push-to-Open installations REQUIRE an accessory Push-to-Open bracket kit (AXPO).
7. Mounting location on gate and support post, column, or wall.
A. Wooden posts should be at least 6" x6" in size and set in concrete.
B. Metal round posts should be at least 3"in diameter and set in concrete.
C. Metal square posts should be at least 4"x 4" in size and set in concrete.
D. Additional mounting bolts may be required if the included bolts are not at least 1"longer than the diameter of
the post.
8. Location and mounting point of control box and battery box. Arm cable length determines how far away from operator arm
that you can mount the control box. THE ARM CABLE CANNOT BE SPLICED OR EXTENDED. PLEASE CALL
TECHNICAL SUPPORT 8508981411 MF 8AM5:30PM EASTERN TIME IF YOU NEED TO EXTEND THE
LENGTH OF THE OPERATOR ARM CABLES.
9. Power source to charge the battery (Solar Power vs. AC Power via transformer)
A. Never use Solar Panels AND an AC transformer on a gate system at the same time or you will damage the
main control board and void any warranty.
B. The AC transformer is designed for indoor use and must be protected in a weather resistant box (that meets
code in your area) if it will be mounted outside.
10. If choosing to use an AC transformer for the battery recharging power source, you should consider the distance from an
outlet to your battery box.
A. No more than 1000 feet of low voltage wire may be used between the AC transformer and the gate
operator system due to electrical losses. If your application exceeds 1000 feet in distance, you must
use Solar Panels for your power source to recharge the batteries.
B. WIRE WILL NEED TO BE PURCHASED SEPARATELY. We offer and recommend 16 gauge
STRANDED, 2CONDUCTOR low voltage wire.
C. The transformer should be on a circuit that is protected by a GFCI plug or breaker.
11. If choosing to use a Solar Panel for the battery recharging power source, you should consider the distance from an outlet to
your battery box.
A. No more than 100 feet of low voltage wire may be used between the Solar Panel and the control box due. If
your application exceeds 100 feet in distance.
B. WIRE WILL NEED TO BE PURCHASED SEPARATELY. We offer and recommend 16 gauge
STRANDED, 2CONDUCTOR low voltage wire.
C. Solar Panel should face south away from trees, and other obstructions that would inhibit getting full sun.
12. How to exit the property and trigger opening operation of the gate (push button, remote transmitter, keypad, or vehicle
exit wand).

17
PLANNING
©Ghost Controls 2018
DETERMINE MOUNTING LOCATION ON GATE AND SUPPORT BAR
You must determine where to mount the gate operator vertically on your gate system. Your gate MUST HAVE A
HORIZONTAL BAR ON THE GATE TO MOUNT THE FRONT OF OPERATOR TO. Each gate is unqiue and Ghost
Controls does not provide this in the kit.
The following three options should be considered when
planning your installation:
■TOP MOUNTING — The gate operator is not
recommended to be mounted to the top of the gate
because the operator may cause twisting or flexing of
the gate while in motion.
■CENTER LINE MOUNTING — This is the most
common and recommended method for mounting an
operator to the gate system.
■BOTTOM MOUNTING — The gate operator must
be mounted high enough o of the ground so that it
does not come in contact with standing or flowing water
which will damage the system. This mounting location
may cause undesirable twisting or flexing of the gate
while in motion.
OPERATOR REAR MOUNT INSTALLATION CONSIDERATIONS
The GHOST CONTROLS®Automatic Gate Operator system is designed for installation on rectangular, square, or round
posts (for 3"or 4"round steel posts, we oer the AX3R AND AX4R ROUND POST ADAPTER ACCESSORIES) or
columns. The rear bracket must be level and secured to the mounting post or column with bolts, nuts, and washers because
this bracket will experience a tremendous amount of force during operation of the automatic gate operator. Proper position-
ing of the rear mounting bracket is critical because it determines:
■Leverage and stability of the operator as it applies force to move the gate
■Necessary clearance between the operator in both the closed and open positions
For PULL-TO-OPEN installations, PLEASE GO TO PAGE 21.
For PUSH-TO-OPEN installations, PLEASE GO TO PAGE 41.
Top Mount
Center Mount
Bottom Mount

18 BLANK PAGE
©Ghost Controls 2018

19
TOOLS NEEDED
©Ghost Controls 2018
Wire Strippers/Cutters
Level
Corded/Cordless Drill
Standard or
Metric Wrenches
Tape Measure
Standard or Metric
Socket Set
5/16" Drill Bit
7/32" Drill Bit
13/32" Drill Bit
(longer than diameter
or thickness of post)
Clamp
Phillips Head
Screwdriver
TOOLS NEEDED

20 PARTS INCLUDED
©Ghost Controls 2018
INCLUDED PARTS IN KIT
Front Mount Hardware
Rear Mount Hardware
Gate Mount Hardware
Gate and Front
Mount Hardware
Post and Rear Mount Hardware
Estate Bracket (Qty 1)
PBK6BA
Other manuals for DTP1
1
Table of contents
Other Ghost Controls Gate Opener manuals

Ghost Controls
Ghost Controls HDP1 Installation instructions

Ghost Controls
Ghost Controls HDP1 Installation instructions

Ghost Controls
Ghost Controls ZombieLock User manual

Ghost Controls
Ghost Controls Ghost Pro LSM1 Installation instructions

Ghost Controls
Ghost Controls TDS2 Installation instructions

Ghost Controls
Ghost Controls HDP2 Installation instructions

Ghost Controls
Ghost Controls DTP1 User manual

Ghost Controls
Ghost Controls Ghost Pro Series Installation instructions

Ghost Controls
Ghost Controls DTP1XP Installation instructions

Ghost Controls
Ghost Controls TSS1 User manual