Gifas Campetto 7 User manual

Campetto 7 Underfloor distributor system
Seite 1 / 10
Created
01.12.2013
ROEN
Modified
01.12.2013
ROEN
Object-ID
359749
Campetto 7 Underfloor distributor system
Manual
VERSION
MODIFICATIONS
1.0
First edition
1.1
Editional changes

Campetto 7 Underfloor distributor system
Seite 2 / 10
Created
01.12.2013
ROEN
Modified
01.12.2013
ROEN
Object-ID
359749
Table of contents
1General information................................................................................................................3
1.1 Marking concept for hazards and hints............................................................................3
1.2 Responsibilities of the operator........................................................................................3
2Applications............................................................................................................................5
2.1 Product features..............................................................................................................5
2.1.1 Basic features and benefits of Campetto 7:..........................................................5
2.2 Scope of delivery.............................................................................................................5
2.3 Technical information ......................................................................................................5
3Introduction ............................................................................................................................6
3.1 Installation conditions Campetto 7 Underfloor distributor system.....................................6
3.1.1 Work to be done on site by customer...................................................................6
3.2 Connecting underfloor distributor to power supply...........................................................7
3.2.1 Principle drawing..................................................................................................7
3.3 Example installation Campetto 7 (with reservoir cover) ...................................................8
3.4 Storage............................................................................................................................9
3.5 Disposal of the device ....................................................................................................9
4Service ..................................................................................................................................10
4.1 Serviceadressen............................................................................................................10
4.2 Impressum ....................................................................................................................10

Campetto 7 Underfloor distributor system
Seite 3 / 10
Created
01.12.2013
ROEN
Modified
01.12.2013
ROEN
Object-ID
359749
1 General information
1.1 Marking concept for hazards and hints
Hazard
Hazardous situation which will cause serious injury or even death if it is not prevented.
Caution
Hazardous situation which could cause slight to moderate injury if it is not prevented.
Hint
Indicates information which does not concern personal injury, e.g. hints in respect of material damage.
Protective measures
Increase safety by applying a protective measure.
1.2 Responsibilities of the operator
-Make sure that this document is always kept in a safe place in a legible form together with the product.
-Read these instructions carefully before first start-up of the product.
-This product has been developed and produced exclusively for the use indicated in these documents.
Every other use, which is not mentioned explicitly, could affect the intactness of the product and/or
could constitute a source of danger.
-The manufacturer rejects any liability for damage which has been caused by incorrect or non-intended
use of the product.
-In countries, which do not belong to the European Community, the national legal reference regulations
as well as the standards and regulations applicable in these countries have to be observed for warranty
of a corresponding safety level.
-The installation has to be carried out according to the applicable regulations.
-The manufacturer assumes no liability for inexpert execution of installation as well as deformations
which may occur during operation.
-The electric power supply has to be switched off before executing any action on the installation.
-Exclusively original parts of the manufacturer shall be used for maintenance. Maintenance work may
be carried out by qualified staff only.
-All procedures which are not explicitly mentioned by the manufacturer in the instructions are not per-
mitted.
-The packing material must not be stored within the reach of children as it could be a potential source
of danger.
-The product must not be installed in hazardous environments. Flammable gases or fumes represent
a serious security risk
-Energy supply of the underfloor distributor has to be protected in accordance with applicable regula-
tions and manufacturer’s details.
-It must be checked whether the earthing system has been installed properly. The metal parts of the
underfloor distributor must be connected to this system.
-If a heating is installed by customer, it is important that the system will be protected by RCD 30mA.
-The manufacturer disclaims any liability with regards to safety and efficient operation of the underfloor
distributor if components are used in the underfloor distribution system which were not approved by
the manufacturer.
-On no part of the underfloor distributor changes should be made, under no circumstances.

Campetto 7 Underfloor distributor system
Seite 4 / 10
Created
01.12.2013
ROEN
Modified
01.12.2013
ROEN
Object-ID
359749
-The installer has to provide the user with all information relating to the operation of the system.
-Make sure that underfloor distribution systems which can only be operated when they are in open
mode, do not provoke any security risk during the operation (risk of unwanted closure of lid, manipu-
lation, e.g.).
-Gas springs are wear parts and must be replaced immediately in case of pressure loss in order to
ensure a safe and gradual closing of the cover (accident risk).
Any optional heating system (heating cover, etc.) may be installed only by authorized personnel.
Locking system, lid hinge bar and gas springs should be checked at appropriate intervals for cleaning and
greasing.
The contact surface of the lid needs also to be cleaned from dirt in appropriate intervals to ensure a safe
closing.
Bolts which are loose (by transport or installation e.g.) should be tightened.

Campetto 7 Underfloor distributor system
Seite 5 / 10
Created
01.12.2013
ROEN
Modified
01.12.2013
ROEN
Object-ID
359749
2 Applications
GIFAS underfloor distributor systems are suitable for:
-Community and market places,
-warehouses, exhibition halls and trade fairs
-Hangars,
-Sport and leisure centres, parks,
-Pedestrian walkways and parking lots
-Shopping centres,
-Plants,
-etc.
… Electricity everywhere, where it is needed quickly, comfortably and regularly!
2.1 Product features
2.1.1 Basic features and benefits of Campetto 7:
-Open casing frame that fits standard concrete pipes
-Cover made from chequered plate
-Cover closed during operation
-low installation depth
-robust, easy and safe to operate
-variety of sizes and distributor models
-low maintenance costs
-highest operational security by GIFAS hard rubber distributor boxes
-resistant to environmental conditions
Size, depth, cover thickness and equipping of the distributor box depend on the customer's specific require-
ments.
2.2 Scope of delivery
The Campetto casing including the electrical distribution and junction box are delivered ready-to-install. Ca-
bling, filling with concrete, drainage e.g. has to be provided by customer.
2.3 Technical information
-designed for electrical, water, and compressed air connections
-the GIFAS hard rubber distributor box assembled on the cover can be equipped individually with any
material
-the built-in connector is adjusted for the connection values and is attached to the frame mount
-the power supply can also be connected directly to the GIFAS hard rubber distributor box using a
flexible cable
-the Campetto cover is available in different load capacities (standard B125, special versions up to
class C250 possible)
-model in V2A stainless steel (galvanized ST37 on request)
-simple and rapid opening and closing supported by gas spring

Campetto 7 Underfloor distributor system
Seite 6 / 10
Created
01.12.2013
ROEN
Modified
01.12.2013
ROEN
Object-ID
359749
3 Introduction
To ensure proper installation, the following steps and notes must be complied with under all circum- stances.
Only this way can it be ensured that the product will work to complete satisfaction.
Hint
Read all instructions before starting installation. Our sales department will be happy to answer any questions
you may have.
3.1 Installation conditions Campetto 7 Underfloor distributor system
3.1.1 Work to be done on site by customer
The cover system is not sealed against surface water; this means that the customer must provide for the
drainage of the underfloor distributor system. The customer must therefore ensure that an appropriate drainage
line or drainage system is installed.
without drainage/drain pipe
With drainage bed (e.g. loose subsurface)
with drain pipe (e.g. solid subsurface)

Campetto 7 Underfloor distributor system
Seite 7 / 10
Created
01.12.2013
ROEN
Modified
01.12.2013
ROEN
Object-ID
359749
Check drainage capacity!
The excavation work as well as the professional and standards-compliant installation must be performed by
the customer. It is important to ensure that the load capacity of the foundation and/or the cover layer corre-
sponds to the load capacity of the underfloor distributor system in order to prevent subsidence. Delivery of
concrete pipe has to be done on site by the customer.
Caution
If the Underfloor distributor system is to be used immediately after the excavation work, the installation pit must
absolutely be secured or locked so that it does not pose a safety risk!
3.2 Connecting underfloor distributor to power supply
Caution
The electrical connection may only be made by trained personnel and is the responsibility of the operator.
3.2.1 Principle drawing
The details necessary for proper installation can be found on the project-specific drawing from GIFAS. Custom
models may vary from the following drawings.

Campetto 7 Underfloor distributor system
Seite 8 / 10
Created
01.12.2013
ROEN
Modified
01.12.2013
ROEN
Object-ID
359749
The cover opens automatically through the use of gas springs. They support muscular force and allow for the
controlled opening and closing of the cover.
3.3 Example installation Campetto 7 (with reservoir cover)
Insert concrete pipe and ensure drainage
Feed electrical supply cord through concrete pipe
Install underfloor distribution system

Campetto 7 Underfloor distributor system
Seite 9 / 10
Created
01.12.2013
ROEN
Modified
01.12.2013
ROEN
Object-ID
359749
Use the levelling bolts to precisely align the Underfloor
distribution system with the surface
Cleanly fill in underneath the Underfloor distribution sys-
tem to prevent subsidence
Fill the reservoir cover
3.4 Storage
No additional measures are required for storage. With regard to packaging, pay attention to protection against
damage.
3.5 Disposal of the device
This product must not be thrown in the garbage.
In accordance with official local and national regulations, this product is to be recycled
appropriately.
European directive 2012/19/EU; waste electrical and electronic equipment (WEEE).

Campetto 7 Underfloor distributor system
Seite 10 / 10
Created
01.12.2013
ROEN
Modified
01.12.2013
ROEN
Object-ID
359749
4 Service
4.1 Serviceadressen
GIFAS ELECTRIC GmbH
GIFAS-ELECTRIC S.r.l
GIFAS ELECTRIC GmbH
GIFAS-ELECTRIC GmbH
Borsigstrasse 9
Via dei Filaracci 45
Pebering-Straß 2
Dietrichstrasse 2
Piano del Quercione
Postfach 275
D-41469 Neuss
I-55054 Massarosa (LU)
A-5301 Eugendorf
CH-9424 Rheineck
+49 2137 105-0
+39 58 497 82 11
+43 6225 7191-0
+41 71 886 44 44
+49 2137 105-230
+39 58 493 99 24
+43 6225 7191-561
+41 71 886 44 49
www.gifas.de
www.gifas.it
www.gifas.at
www.gifas.ch
info@gifas.it
info@gifas.ch
4.2 Impressum
GIFAS-ELECTRIC GmbH
CH-9424 Rheineck
www.gifas.ch
Technische Änderungen und Irrtümer vorbehalten.
Dieses Dokument ist Eigentum der GIFAS-ELECTRIC GmbH und darf ohne vorherige schriftliche Genehmi-
gung durch GIFAS-ELECTRIC GmbH weder ganz noch in Auszügen kopiert, übersetzt, übertragen, dupliziert
oder an Dritte weitergegeben werden.