Usage
Technical Parameters
Please bind the ambience sensor with SmartC gateway before use:
Long press the bind button for 5 seconds, the LCD will show "BINDING..." and send out binding
request. Add a new smart device binding on APP "ZGinger Mini", you can refer to the instruction
manual of SmartC gateway for the detailed procedure .
Short press awake button can switch the LCD display interface between CO2 and PM2.5 (GW-4321A).
1. Please keep nothing coverved on the air-vent of sensor.
2. The mounting position must be larger than 0.75m apart from the corner of wall, larger than 0.2m
apart from the ground.
3. Semiannual clean for sensor is recommeded.
Shenzhen Gingerway Technologies Co., Ltd.
Address: 3-Floor, Building A6, Xingye Industrial Park, Zhongshanyuan No.2 Road, Nanshan
District. Shenzhen, Guangdong, China.
Tel :0755 -28779595 Fax :0755 -28779405
Website: www.gingerway.com
Gingerway products are guaranteed for 2 years since the date of purchase. During the warranty
period, if Gingerway products malfunction(not contain artificial damages) under normal
circumstances, they can be free repaired or exchanged at local dealer with the purchase invoice.
1. If due to quality failure during the warranty period, the maintenance is free in rst year, only
the component cost will be charged in the second year.
2. Disassembling Gingerway product components without the permission of our company or the
local client center, our company will no longer bear the free warranty responsibility .
Note: Shenzhen Gingerway Technologies Co., Ltd reserves the right of nal explanation for above
terms.
0678
Warranty Terms
Attention
Power Supply 5VDC / 12VDC Maxmium Power
Consumption
≤ 0.2W
RF 433MHz RF Transmit Power ~10dbm
Eective Range of
Particulate Mass
Concentration (PM2.5
standard value)
0-500μg/m³ Display Range of
Particulate Mass
Concentration (PM2.5
standard value)
0-999μg/m³
Consistency of
Particulate Mass
Concentration (PM2.5
standard value)
±10μg/m³ (0-100)
±10% (100-500)
Resolution of Particulate
Mass
Concentration (PM2.5
standard value)
1μg/m³
Temperature
Measurement Range
-20℃-60℃ Accruancy Measurement
Range
±0.5℃ (-10℃-60℃)
±1℃ (-20℃- -10℃)
CO2 Measurement
Range
0-9999ppm CO2 Measurement
Accuracy (25℃.101.3KP
atmosphere)
±40ppm±3% Reading
Humidity Measurement
Range
0-99% RH Humidity Measurement
Accuracy (25℃)
±2%RH (10-90% typical
value)
±8%RH (Max value in
other case)
Dimensions(L * W * H) 77mm*77mm*34mm Weight 102g