Gingerway GW-4312 User manual

Descriptions
Dear users, sincerely thank you for choosing our products. For your convenience of installing and using
this product, please read this manual carefully before use.
Being equipped with high-precision laser sensor and LCD screen , Gingerway ambience sensor GW-
4321 can accurately measure the PM2.5 value, temperature and humidity of current ambience. GW-
4312A also with CO2 concentration measuring function.
1. Draw the position of 2 bracket screw holes point to the wall, punch holes at the position by drill, then
insert anchorings to x the bracket on the wall.
2. Fasten the sensor on mounting bracket.
Ambience Sensor Instruction Manual
GW-4312 (PM2.5)
GW-4312A (PM2.5+CO2)
Gingerway Technologies Co.,Ltd
Enjoy the life
Product Structure Diagram
Installation
201807 V1.0
Main Features
√ Z-Ginger® full-digital, highly reliable, large coverage, low power consumption internet of things
two-way wireless network
√ With built-in high precision laser particulate mass concentration sensor
√ Non-Dispersive Infrared (NDIR) CO2 sensor(GW-4312A)
√ Digital temperature and humidity sensor
√ Lattice LCD screen, clear and intuitive
√ Automatically upload data to the cloud (Must be used with SmartC gateway)
√ Trigger linkage control based on measurement results (Must be used with SmartC gateway )
√ Professional APP, multi-dimensional historical and real-time data display
√ Ultra-low standby power consumption
√ USB+12V DC dual input power design
1. Wake/Bind Button
2. LCD
3. Current Temperature
4. Current PM2.5 Value
5. USB Power Port
6. Current Humidity
7. Air Quality Level
8. CO2 Concentration
①
②
③
④
⑤
⑥
⑦
⑧
Usage
Technical Parameters
Please bind the ambience sensor with SmartC gateway before use:
Long press the bind button for 5 seconds, the LCD will show "BINDING..." and send out binding
request. Add a new smart device binding on APP "ZGinger Mini", you can refer to the instruction
manual of SmartC gateway for the detailed procedure .
Short press awake button can switch the LCD display interface between CO2 and PM2.5 (GW-4321A).
1. Please keep nothing coverved on the air-vent of sensor.
2. The mounting position must be larger than 0.75m apart from the corner of wall, larger than 0.2m
apart from the ground.
3. Semiannual clean for sensor is recommeded.
Shenzhen Gingerway Technologies Co., Ltd.
Address: 3-Floor, Building A6, Xingye Industrial Park, Zhongshanyuan No.2 Road, Nanshan
District. Shenzhen, Guangdong, China.
Tel :0755 -28779595 Fax :0755 -28779405
Website: www.gingerway.com
Gingerway products are guaranteed for 2 years since the date of purchase. During the warranty
period, if Gingerway products malfunction(not contain artificial damages) under normal
circumstances, they can be free repaired or exchanged at local dealer with the purchase invoice.
1. If due to quality failure during the warranty period, the maintenance is free in rst year, only
the component cost will be charged in the second year.
2. Disassembling Gingerway product components without the permission of our company or the
local client center, our company will no longer bear the free warranty responsibility .
Note: Shenzhen Gingerway Technologies Co., Ltd reserves the right of nal explanation for above
terms.
0678
Warranty Terms
Attention
Power Supply 5VDC / 12VDC Maxmium Power
Consumption
≤ 0.2W
RF 433MHz RF Transmit Power ~10dbm
Eective Range of
Particulate Mass
Concentration (PM2.5
standard value)
0-500μg/m³ Display Range of
Particulate Mass
Concentration (PM2.5
standard value)
0-999μg/m³
Consistency of
Particulate Mass
Concentration (PM2.5
standard value)
±10μg/m³ (0-100)
±10% (100-500)
Resolution of Particulate
Mass
Concentration (PM2.5
standard value)
1μg/m³
Temperature
Measurement Range
-20℃-60℃ Accruancy Measurement
Range
±0.5℃ (-10℃-60℃)
±1℃ (-20℃- -10℃)
CO2 Measurement
Range
0-9999ppm CO2 Measurement
Accuracy (25℃.101.3KP
atmosphere)
±40ppm±3% Reading
Humidity Measurement
Range
0-99% RH Humidity Measurement
Accuracy (25℃)
±2%RH (10-90% typical
value)
±8%RH (Max value in
other case)
Dimensions(L * W * H) 77mm*77mm*34mm Weight 102g

This manual suits for next models

1

Popular Temperature Controllers manuals by other brands

Carbolite 91e operating instructions

Carbolite

Carbolite 91e operating instructions

Hussmann Safe-NET III User instructions

Hussmann

Hussmann Safe-NET III User instructions

Brookfield TC Series Operator's manual

Brookfield

Brookfield TC Series Operator's manual

Ogden ETR-901 instruction manual

Ogden

Ogden ETR-901 instruction manual

Cumberland Integra EXPERT 64EU user manual

Cumberland

Cumberland Integra EXPERT 64EU user manual

Kathrein ESO 005 Guide

Kathrein

Kathrein ESO 005 Guide

ILX Lightwave LDT-5416 user guide

ILX Lightwave

ILX Lightwave LDT-5416 user guide

Siemens 24RFDC/SET manual

Siemens

Siemens 24RFDC/SET manual

Shini STMC-W manual

Shini

Shini STMC-W manual

aci DH2630A Installation and operation instruction

aci

aci DH2630A Installation and operation instruction

RKC INSTRUMENT REX-S100 instruction manual

RKC INSTRUMENT

RKC INSTRUMENT REX-S100 instruction manual

Sterlco 6017 Series Operation and installation manual

Sterlco

Sterlco 6017 Series Operation and installation manual

meitav-tec ERT100-LCD-IR operating manual

meitav-tec

meitav-tec ERT100-LCD-IR operating manual

Siemens DT-11 Installation, operation and maintenance

Siemens

Siemens DT-11 Installation, operation and maintenance

DirekTronik LSN50v2-D20 user manual

DirekTronik

DirekTronik LSN50v2-D20 user manual

dixell IC200CX Series user manual

dixell

dixell IC200CX Series user manual

D+H RTR 231 Original instructions

D+H

D+H RTR 231 Original instructions

RedWave Labs LTC25 operating manual

RedWave Labs

RedWave Labs LTC25 operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.