Glastender LP60 User manual

Operation Manual, Parts Directory and Price List
Glastender, Inc. · North Michigan Road · Saginaw, MI · 48604-9780
800.748.0423 · 989.752.4275 · Fax 800.838.0888 / 989.752.4444 · www.glastender.com
© 2008 Glastender, Inc.
Vertical Door coolers
self-containeD MoDels - BB24, BB36, BB60, BB84, BB108, ND52, ND72, ND92, FV24,
FV48, LP60, LP84, LP108, PT60, PT84, PT108, KC24, KC48, KC52, KC72, KC84
reMote MoDels - BB24, BB48, BB72, BB96, LP48, LP72, LP96, PT48, PT72, PT96
Dry storage MoDels -DS24, DS48, DS72, LPDS24
Rev. 08-26-08
BB60-L1-XSH(LR)
PT60-L1-LLH(LR/RL)
BB72-R1-BLN(LLR)
FV24-BS(L)
shown with optional wood panel doors


serVice anD Parts
Terms and Conditions...................................................................................... 1
Warranty .......................................................................................................... 1
installation
Introduction ..................................................................................................... 2
Utility Requirements and Connections ........................................................... 2
Uncrating and Start-Up Instructions ............................................................... 2
Operation ......................................................................................................... 2
Cleaning Instructions....................................................................................... 3
Floor Sealing Instructions ............................................................................... 3
Cooler Installation Checklist........................................................................... 4
Cooler Design Change .................................................................................... 5
sPecifications
Electrical and Refrigeration Specifications..................................................... 6
Wiring Diagrams ........................................................................................ 7-11
Endwall Models ........................................................................................ 7
Self-Contained Models ............................................................................. 8
Remote Models......................................................................................... 9
Remote Models with Solenoid Control .................................................. 10
Built-in Fluorescent Light Fixtures ........................................................ 10
BB24 Self-contained and KC24 Models .................................................11
rePlaceMent Parts
Compressor and Condenser Related Parts ............................................... 12-19
BB24 Self-Contained & KC24............................................................... 12
BB36 ....................................................................................................... 13
LP60, LP84, LP108, and Non Endwall BB60, BB84, BB108,
ND52, ND72, ND92, KC72, and KC84................................................. 14
BB36, BB60, ND52, and KC52 Endwall............................................... 15
BB84, BB108, ND72, ND92, KC72, and KC84 Endwall ..................... 16
KC48....................................................................................................... 17
PT60, PT84, PT108 ................................................................................ 18
FV24 and FV48 ..................................................................................... 19
Evaporator and Related Parts................................................................... 20-22
Doors and Related Parts........................................................................... 23-26
Shelving, Racks and Related Parts................................................................ 27
Refrigeration Compartment Covers .............................................................. 28
220 Volt Electrical Parts........................................................................... 29-30
inDex
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 800.838.0888 / 989.752.4444 • www.glastender.com


Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 800.838.0888 / 989.752.4444 • www.glastender.com 1
Prices:
All prices are LIST. Applicable taxes will be added.
Quotations:
Unless otherwise stated, quotations are effective for 30 days only.
accePtance:
All orders are subject to acceptance by Glastender, Inc.’s headquarters
in Saginaw, Michigan. Possession of the Parts Directory and Price List
is not an offer to sell.
shiPMents:
F.O.B. factory in Saginaw, Michigan. Partial shipments will be made
unless otherwise specified by the customer. Orders are shipped via UPS
or DHL unless otherwise specified.
PayMent terMs:
Cash should be included with all orders unless credit terms have been
arranged. To establish credit, banking and trade references are required.
A convenient credit application is available upon request. Visa and
Mastercard are also accepted.
DeliVery:
Varies according to prior production commitments, but parts orders
generally ship within two working days.
returns:
A Return Authorization (RA) number must be issued by the factory in
advance for any items that are returnable. The RA number MUST be
noted on the outside of the returned package. Returns must be received
within 90 days of the RA issue date. Shipping charges must be prepaid.
A 20% handling charge will be applied to all authorized returns if
received in new, unused condition in the original packaging.
loss or DaMage:
Glastender, Inc. is not responsible for any loss, damage, or delay of
merchandise during shipment. Such transit claims must be filed with
the carrier. Merchandise must be examined on arrival. If shortages
occur, Glastender, Inc. must be notified in writing within five (5) days
of delivery to honor any shortage claim.
NOTE: Glastender, Inc.’s policy of constant quality improvement means
that prices, specifications, and policies are subject to change without
notice.
IMPORTANT!!
Attention Refrigeration Service Companies
Please review the important warranty information on this page. If you believe a
service call should be covered by the factory, please call the factory for authorization
between 8AM and 5PM EST, Monday through Friday.
terMs anD conDitions
Warranty stateMent
LABOR: Glastender, Inc. warrants all products to be free of defects in
material and workmanship. In established areas, a start-up and a 90-
day labor warranty are included with glasswasher models GT-24 and
GT-30. The GT-18 series glasswashers include a 90-day labor warranty.
Self-contained refrigeration models, except beer line chillers, include a
1-year labor warranty, for the duration of one year from date of instal-
lation or up to 18 months from date of factory shipment, whichever
occurs sooner. For warranty labor claims beyond 15 months from the
date of factory shipment, proof of date of installation or occupancy must
be provided. Authorization for labor must be obtained from Glastender
within the warranty period and prior to the service being performed.
Labor warranty applies to the United States and Canada only.
PARTS: Within one year from date of installation, or 15 months from
date of factory shipment, whichever occurs sooner, Glastender, Inc.
will replace any part or assembly found defective under normal use and
service. Field replacement parts include a warranty of 90 days from date
of installation. All self-contained refrigeration models include a 5-year
compressor warranty.
A warranty claim form MUST accompany all returned defective parts or
assemblies. This form MUST be completed in full. Failure to do so may
result in delay or denial of credit. Any defective part or assembly must
be returned to Glastender, Inc., Saginaw, Michigan, with all transporta-
tion and delivery charges prepaid. Warranty repairs or replacements will
be shipped FOB factory in Saginaw, Michigan.
The warranty does not cover equipment subjected to accidents, freight
damage, alterations, improper power and/or plumbing hookups, improp-
er chemical use, general misuse, or lack of routine required maintenance
as determined by Glastender, Inc.
No representative, distributor, dealer, or any other person is authorized
to modify this warranty. This warranty replaces all other written or
verbal warranties.
NOTE: Glastender, Inc.’s policy of constant quality improvement
means that prices, specifications, and policies are subject to change
without notice. Questions regarding this warranty should be directed to
Glastender’s Customer Service Representative.
03/01/07

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 800.838.0888 / 989.752.4444 • www.glastender.com
2
introDuction
This manual describes the operational features of Vertical Door Coolers. Please review this information before
attempting installation and operation.
Long term, trouble-free service will follow if good housekeeping and maintenance procedures are followed.
Thank you for selecting Glastender, Inc. products.
utility reQuireMents anD connections
• Electrical: 115 Volt AC, 1 Phase, 60 Hz. A separate 15 Amp circuit is recommended. A 6-foot grounded
cord and plug is included with self-contained models.
• Plumbing:
Self-contained Models: Automatic condensate evaporator is included. No drain connection
required.
Remote Models: An external drain connection is required. Use the ten foot length of 1/2” ID by
5/8” OD plastic tubing provided to run the drain line for condensate. The tubing should exit
through one of the 3/4” side knock-out holes.
Self-contained Keg Coolers: The drain pain drain is pre-plumbed at the factory to stub out below
the compressor compartment. A field connection to an external drain must be made from that point.
uncrating anD start-uPinstructions
All models are shipped in one carton. These steps should be followed:
1. If legs or casters are included, bolt them to the base with the bolts provided.
2. Unwrap power cord from base if included.
3. Position unit and level and/or seal as required (see page 2 and 3).
4. The evaporator drain pan on remote models must be plumbed to an external drain. All units with draft
beer must be plumbed to an external drain (except model KC24 which includes an internal plastic drain
bottle). On self-contained models with draft beer and a factory installed finished top, the beer tower drain
pan is plumbed through the cabinet and stubs out in the 3” space below the compressor compartment.
Connection to an external drain must be made from that point.
5. Place shelves in desired location.
6. Plug into 115 volt AC outlet if a power cord is included. Remote models require electrical connections
to be made by an electrician or remote refrigeration contractor.
7. Load with bottles or cans and allow time for products to cool.
8. Your Glastender equipment is now ready for use.
oPeration
The operating temperature range is 36°F (2°C) to 40°F (5°C).
Self-contained models include an automatic defrost system. The refrigerator will defrost every six hours for
approximately 20 minutes. Endwall coolers will defrost every four hours for approximately 15 minutes. During
the defrost, the fan inside the cooler will remain on and the refrigeration system will turn off.
installation

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 800.838.0888 / 989.752.4444 • www.glastender.com 3
installation
COOLER DOOR
COOLER CABINET
1" BASE
BEAD SEALANT
FLOOR
MAGNETIC GASKET
Side View of Cabinet
cleaning instructions
Cleaning is essential to sustaining the integrity of your equipment and preventing corrosion.
ESTIMATED CLEANING TIME: 5 to 10 minutes per unit daily, 45 minutes quarterly
FREQUENCY: Daily cleaning of exterior & door gaskets. Quarterly cleaning of interior, including shelves.
PROCEDURE:
1. A non-chlorine based cleaner or mild detergent and warm water applied with a soft cloth or sponge to all
contact surfaces.
2. Immediately rinse off cleaning agent(s), using clean warm water, clean soft cloth or sponge.
3. Dry with a soft clean cloth, removing standing water as soon as possible.
NOTES:
1. Never use hydrochloric acid, wire brushes, steel wool, scrapers, or chlorine based cleaners on stainless steel
surfaces, since they will break down the passivity layer and allow corrosion to occur.
2. On stainless steel surfaces, you may use a soft bristle brush or Scotch-Brite®pad for more stubborn stains.
Always scrub with the direction of the grain. Follow with a thorough cleaning as described above.
3. Deposits from food preparation must be properly removed. Even hard water deposits will rust stainless steel,
if not removed.
4. Repeated cleaning may dry up black-vinyl-clad steel (exterior) surfaces of the cooler. Armor All®or similar
product can bring back the shine. Apply the product to a cloth and then rub into the surface, rather than spray-
ing it directly onto the black-vinyl-clad surface.
5. The cooler door gaskets are most often overlooked when cleaning. Failure to clean them regularly will lead to
premature failure, since alcohol and moisture build-up breaks down the gasket material.
sealing Vertical Door cooler to floor
To comply with NSF & health codes, the cooler base must be sealed to the floor using NSF listed sealant. Place
a bead of sealant along outer edges of the base and remove excess with disposable towel. The floor sealing
procedure does not apply to models that include legs or casters.

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 800.838.0888 / 989.752.4444 • www.glastender.com
4
attention installer:wARNING!!
Failure to level this cooler WILL VOID THE FACTORY WARRANTY. Doors will not close properly causing
damage to hinges, handles, and/or gaskets which will adversely affect the refrigeration systems.
cooler installation checklist
Is the unit evenly and solidly supported, either upon legs, or flat on the base; check for high spots?
If the unit was designed for legs, are they attached?
Is the unit level at the base, from end to end?
Do the doors open and close freely, without touching any other part of the unit in travel?
Are there open holes to the outside of the cabinet which are not plugged or insulated?
Are there obstructions of any kind to air flow into or out of the condensing unit?
Is product tubing or are other lines installed in such a manner to not allow shelf access?
installation
COOLER WITH 6” LEGS
sPecial instructions for keg coolers
Before you begin:
1. Disassemble the tower into three parts, stiffener, skin, and top plate,
by unscrewing the top two screws.
2. Mount the column stiffener with the four 1/4”-20x1-1/4” bolts pro-
vided.
3. Install insulation provided into the bottom of the column stiffener.
4. Place the column skin over the stiffener. Run the beer lines through
the hole at the same time.
5. Install insulation provided into the top of the tower assembly.
6. Mount the column top plate to the column stiffener with the two #10-32x1/2” phillips at head s/s machine
screws provided.
7. Apply a bead of silicone sealant around the perimeter of the column. Use your nger to smooth out the bead.
8. Wash tapping device and faucet with detergent and water. Flush beer tapping device and faucet lines.
COOLER WITHOUT LEGS
stiffener skin
top plate

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 800.838.0888 / 989.752.4444 • www.glastender.com 5
cooler Design change
iMPortant Design change inforMation
In February 2004, Glastender released new BB and ND self contained cooler designs with the evaporator hous-
ing moved into an area above the compressor compartment. The serial numbers for these units will be 90000 and
above. As of September 2006, KC52, KC72, and KC84 model keg coolers are being manufactured as endwall
models. Due to special customer request some BB and ND self contained models may not have the endwall
design. Please be sure to verify which cooler design type you are ordering parts for. The term endwall will be
used throughout this document to denote parts used for coolers featuring this design.
Standard cooler conguration with evaporator inside cooler area. Compressor compartment
may be located left or right.
Endwall cooler conguration (most BB and ND models manufactured after Feb. 2004, most
KC models manufactured after Sept. 2006) with evaporator located in housing above the
compressor compartment. Compressor compartment may be located left or right.

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 800.838.0888 / 989.752.4444 • www.glastender.com
6
electrical anD refrigeration sPecifications
BB24 self-containeD & kc24 ManufactureD after 4/14/06
electrical refrigerant Pressure P.s.i.g.
115V, 1 phase, 60 Hz tyPe charge high loW
4.0 full load amps, 1/6 HP R134a 5.0 oz. 200 85
kc24 ManufactureD Before 4/14/06
electrical refrigerant Pressure P.s.i.g.
115V, 1 phase, 60 Hz tyPe charge high loW
2.8 full load amps, 1/6 HP R134a 5.0 oz. 200 85
fV24, fV48, anD BB36 self-containeD MoDels ManufactureD Before 2/04
electrical refrigerant Pressure P.s.i.g.
115V, 1 phase, 60 Hz tyPe charge high loW
5.1 full load amps, 1/5 HP R22 13.5 oz. 285 144
BB24 reMote, BB48, BB72, BB96, lP48, lP72, lP96, Pt48, Pt72, Pt96
electrical refrigerant Pressure P.s.i.g.
115V, 1 phase, 60 Hz tyPe charge high loW
R22 n/a n/a n/a
lP60, lP84, lP108 & non-enDWall BB60, BB84, BB108, kc48, kc72, & kc84
electrical refrigerant Pressure P.s.i.g.
115V, 1 phase, 60 Hz tyPe charge high loW
8.8 full load amps, 1/3 HP R22 13.5 oz. 285 144
PT60, PT84
electrical refrigerant Pressure P.s.i.g.
115V, 1 phase, 60 Hz tyPe charge high loW
8.8 full load amps, 1/3 HP R404a 9.0 oz. 285 144
PT108
electrical refrigerant Pressure P.s.i.g.
115V, 1 phase, 60 Hz tyPe charge high loW
8.8 full load amps, 1/3 HP R404a 10.0 oz. 285 144
BB36, BB60, nD52, kc52 enDWall MoDels
electrical refrigerant Pressure P.s.i.g.
115V, 1 phase, 60 Hz tyPe charge high loW
7.2 full load amps, 1/3 HP R134a *12.0 oz. 186 88
* 12.0 oz. charge Serial #134-106565-F and after. 20.0 oz. charge prior to Serial #134-106565-F.
BB84, BB108, nD72, nD92, kc72, kc84 enDWall MoDels
electrical refrigerant Pressure P.s.i.g.
115V, 1 phase, 60 Hz tyPe charge high loW
10.1 full load amps, 1/3 HP R404a 16.0 oz. 331 174

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 800.838.0888 / 989.752.4444 • www.glastender.com 7
Wiring DiagraM for BB36, BB60, nD52, & kc52 enDWall MoDels
Wiring DiagraM for MoDels BB84, BB108,
nD72, nD92, kc72, & kc84 enDWall MoDels
LIGHT RECEPTICAL AUX. RECEPTICAL
115v AC
15amp
POWER
CORD
SUPPLY
MAIN
ORANGE
STARTER
COMPRESSOR
COMMON
RUN
RELAY
START
BLACK WHITE
OVERLOAD
BLACK ORANGE
THERMOSTAT
EVAPORATOR FAN
CONDENSER FAN
BLACK
BLACK
WHITE
GREEN
BLUE
LIGHT SWITCH
BLACK
BLUE
BLUE
WHITE
DEFROST TIMER
WHITE
BLACK
WHITE
WHITE
BLUE
2 1 4 3
LIGHT RECEPTICAL AUX. RECEPTICAL
115v AC
15amp
POWER
CORD
SUPPLY
MAIN
ORANGE
STARTER
COMPRESSOR
COMMON
RUN
RELAY
START
BLACK WHITE
OVERLOAD
BLACK ORANGE
THERMOSTAT
EVAPORATOR FAN
CONDENSER FAN
BLACK
BLACK
WHITE
GREEN
BLUE
LIGHT SWITCH
BLACK
BLUE
BLUE
WHITE
DEFROST TIMER
WHITE
BLACK
WHITE
WHITE
BLUE
2 1 4 3

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 800.838.0888 / 989.752.4444 • www.glastender.com
8
Wiring DiagraM for self-containeD lP60, lP84, lP108, Pt60, Pt84, Pt108,
& non enDWall BB36, BB60, BB84, BB108, nD52, nD72, nD92, kc48, kc72, kc84*
*NOTE: See page 7 for endwall BB, ND, and KC self-contained model wiring diagrams
G
Evaporator Assembly
Note: Some Units May HaveTwo Fans (Three Fans Shown)
Condenser Fan Motor
Compressor
Evaporator Fan Motor
W = White
G = Green
O = Orange
BL = Blue
B = Black
115V
115V
115V
All wires are 16 Gauge
.80 AMP
7.05 AMP
.28 AMP(Each)
ELECTRICAL RATINGS
G
W
6
15 AMP SERVICE RECOMMENDED
G
W
B
LEGEND
115 VOLT
BL
BL
4
1
M
1
2
2
BL
1
2
1
10
12
11
G
W
9
7
O
B
C
S
M
W
M
CONDENSING UNIT
2
1
B
8
CONDENSER FAN BLADE
CONDENSER FAN MOTOR
CABINET LIGHT RECEPTACLE
EVAPORATOR FAN MOTOR
EVAPORATOR FAN BLADE
O
3
BBL
5
O
O
W
12
DEFROST TIMER
OVERLOAD
CAPACITOR
COMPRESSOR
START RELAY
9
10
11
5
6
8
7
THERMOSTAT
LIGHT SWITCH3
4
2
ITEM
1
DESCRIPTION
S
S
13
13
14
14
15
15
14
14
STARTER
TOMBSTONE
BALLAST13
15
14
B
BB
BB
B
W
W
W

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 800.838.0888 / 989.752.4444 • www.glastender.com 9
Wiring DiagraM for reMote coolers incluDing MoDels
BB24, BB48, BB72, BB96, lP48, lP72, lP96, Pt48, Pt72, Pt96
5
22
1
11
2
4
3
NEUTRAL
REMOTE
CONDENSING
UNIT
115V
Note: Some Units May Have Two Fans (Three Fans Shown)
Evaporator Assembly
DESCRIPTION
EVAPORATOR FAN BLADE
EVAPORATOR FAN MOTOR
ITEM
1
2
4
3 LIGHT SWITCH
THERMOSTAT
5 DEFROST TIMER
TO LIGHTS
All wires are 16 Gauge
Evaporator Fan Motor
ELECTRICAL RATINGS
R = Red
Y = Yellow
LEGEND
BK = Black
BL = Blue
O = Orange
G = Green
W = White
115V .28 AMP(Each)
O
C
4O
W
M
1
O
BL
G
O O
BL
BLBL
Y/BL = Yellow
w/blue stripe
Y/R = Yellow
w/red stripe

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 800.838.0888 / 989.752.4444 • www.glastender.com
10
Wiring DiagraM for MoDels after 2/15/00
With fluorescent light systeM
Wiring DiagraM for reMote coolers With solenoiD for
installing More than one unit on one conDensing unit
5
22
1
11
2
4
3
NEUTRAL
115V
Note: Some Units May Have Two Fans (Three Fans Shown)
Evaporator Assembly
DESCRIPTION
EVAPORATOR FAN BLADE
EVAPORATOR FAN MOTOR
ITEM
1
2
4
3 LIGHT SWITCH
THERMOSTAT
5 DEFROST TIMER
TO LIGHTS
All wires are 16 Gauge
Evaporator Fan Motor
ELECTRICAL RATINGS
R = Red
Y = Yellow
LEGEND
BK = Black
BL = Blue
O = Orange
G = Green
W = White
115V .28 AMP(Each)
4O
O
W
M
1
BL
G
O O
BL
BLBL
Y/BL = Yellow
w/blue stripe
Y/R = Yellow
w/red stripe
W
S
FLOURESCENT LIGHT SYSTEM
TWO LIGHT
W
115V
R
W
Y/R
Y/BL
BALLAST
BL
BK
FLOURESCENT LIGHT SYSTEM
ONE LIGHT
115V
LIGHT
LIGHT
BL
BL
R
R
BL
BALLAST
STARTER
W
BB
LIGHT
R
B
R

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 800.838.0888 / 989.752.4444 • www.glastender.com 11
Wiring DiagraM for BB24 self-containeD & kc24 after 4/14/06
BL
BL
BL
W
W
W
G
ALL WIRE 16GA.
THERMOSTAT START
RELAY
S
M
OVERLOAD
R
COMPRESSOR
S
COL
120 VOLTS
POWER CORD
4
M
1
CONDENSER
FAN
MOTOR
EVAPORATOR
FAN
MOTOR
TOTAL 3.1 AMPS
OL
S
THERMOSTAT START
RELAY
COMPRESSOR OVERLOAD
ELECTRICAL RATINGS
COMPRESSOR, 2.7 AMPS
ALL WIRE 16GA.
120 VOLTS
POWER CORD
FAN
TOWER
COOLING
MOTOR
BL
BL W
W
O
G
MR
S
C
kc24 Before 4/14/06 Wiring DiagraM

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 800.838.0888 / 989.752.4444 • www.glastender.com
12
BB24 self-containeD & kc24 coMPressor, conDenser anD relateD Parts
5
7
1
10
413
4
6
8
3
2
9
12
11
14
Part no. olD Part no. DescriPtion Price
1. 06001435 GT-035006 1/6 HP Aspera compressor, R134a $390.00
2. 06001647 GT-034101 Relay for 1/6 HP Aspera R134a compressor 13.00
3. 06001341 GT-031200 Overload protector for 1/6 HP Aspera R134a compressor 13.00
4. 06001397 GT-033000 Automatic defrost timer 32.00
5. 06001694 GT-035131 Condenser fan motor 35.00
6. 09000298 GT-032804 Condenser fan motor blade 5.00
06001125 GT-032315 Beer tower cooling fan shroud (KC24 models 05/01 - 04/14/06) 17.00
06001452 GT-035128 Beer Tower Cooling Fan Motor (KC24 models 05/01 - 04/14/06) 65.00
06001396 GT-032809 Exterior blade assembly (KC24 models 05/01 - 04/14/06) 10.00
06001395 GT-032802 Interior blade assembly (KC24 models 05/01 - 04/14/06) 5.00
7. 07000133 GT-031513 Condenser fan motor mounting bracket 20.00
8. 04000100 GT-032608 Condenser coil (7” L, 6-7/8” H, 2-1/2” W) 130.00
06001389 GT-032611 Static condenser coil (KC24 before 04/14/06) 125.00
9. 06004028 Filter dryer with service port 25.00
10. 06000176 GT-038000 Condensate pan 42.00
11. 07000234 Wicking material 24.00
05000644 Wicking Material (KC24 before 04/14/06) 10.00
12. 04000124 GT-032509 Cap tube 96” X .036 20.00
13. 06001405 GT-033202 Thermostat with knob and plate [Selco] 50.00
14. 06001632 GT-038419 Knob only 3.00

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 800.838.0888 / 989.752.4444 • www.glastender.com 13
4
3
14
13
16
12
11
10
stanDarD BB36 coMPressor anD conDenser relateD Parts
Part no. olD Part no. DescriPtion Price
1. 11000082 GT-035005 1/5 HP Aspera compressor, R22 $535.00
2. 06001379 GT-032201 Start capacitor for 1/5 HP Aspera R22 compressor 20.00
3. 08000083 GT-034107 Relay for 1/5 HP Aspera R22 compressor 15.00
4. 08000069 GT-031204 Overload protector for 1/5 HP Aspera R22 compressor 15.00
06001444 GT-035027 1/5 HP Tecumseh compressor, R22 (after 4/00) 490.00
06001382 GT-032211 Start capacitor for 1/5 HP Tecumseh R22 compressor 15.00
06001415 GT-034117 Relay for 1/5 HP Tecumseh R22 compressor 19.00
06001303 GT-031212 Overload protector for 1/5 HP Tecumseh R22 compressor 9.00
5. 08000085 GT-035106 Condenser fan motor, 16W 110.00
6. 08000081 GT-032801 Condenser fan motor blade assembly 13.00
7. 06001321 GT-031515 Condenser fan motor mounting bracket 5.00
8. 08000076 GT-032601 Condenser coil (10”L x 7-15/16”W x 4”D) 220.00
9. 08000075 GT-032307 Fan shroud, condenser 11.00
10. 06004028 Filter dryer with service port 25.00
11. 06001648 GT-038001 Condensate pan (13-3/4”L x 9-1/2”W x 1”D) 58.00
12. 07000234 GT-038201 Wicking material (2 required) 24.00
13. 06001461 Elbow, white nylon, 1/2” x 1/2” 2.00
14. 06001345 GT-031716 Tubing, drain, clear plastic, 1/2” ID x 5/8” OD, per foot 1.45
15. 08000074 GT-031532 Base, condensing unit 30.00
16. 06001397 GT-033000 Automatic defrost timer, 6hr. 32.00
17. 06001313 GT-031400 Condensing unit power cord 20.00
11000120 GT-031717 Cap tube 60” X .036 20.00
18. 06001384 GT-032501 Accumulator, suction line 40.00
7
2
115
8
9
6
5
10
17
18

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 800.838.0888 / 989.752.4444 • www.glastender.com
14
coMPressor anD conDenser relateD Parts for lP60, lP84, lP108,
& non enDWall BB60, BB84, BB108, nD52, nD72, nD92, kc72, anD kc84
1/3 HP, R22
(BB60, BB84, BB108, ND52, ND72, LP60,
LP84, LP108, KC72, KC84)
9
1
2
8
17
5
15
10
12
11
16
14
13
4
3
Part no. olD Part no. DescriPtion Price
1. 07000172 GT-035002 1/3 HP Aspera compressor, R22 $500.00
2. 06001379 GT-032201 Start capacitor for 1/3 Aspera HP R22 compressor 20.00
3. 06001414 GT-034103 Relay for 1/3 HP Aspera R22 compressor 14.00
4. 08000068 GT-031202 Overload protector for 1/3 HP Aspera R22 compressor 12.00
06001443 GT-035025 1/3 HP Tecumseh compressor, R22 (after 2/00) 400.00
06001380 GT-032206 Start capacitor for 1/3 HP Tecumseh R22 compressor 20.00
07000168 GT-034112 Relay for 1/3 HP Tecumseh R22 compressor 18.00
07000128 GT-031207 Overload protector for 1/3 HP Tecumseh R22 compressor 12.00
5. 08000085 GT-035106 Condenser fan motor 110.00
6. 08000081 GT-032801 Condenser fan motor blade assembly 13.00
7. 06001321 GT-031515 Condenser fan motor mounting bracket 5.00
8. 08000076 GT-032601 Condenser coil (10”L x 7-15/16”W x 4”D) 220.00
9. 08000075 GT-032307 Fan shroud, condenser 11.00
10. 06004028 Filter dryer with service port 25.00
11. 06001648 GT-038001 Condensate pan (13-3/4”L x 9-1/2”W x 1”D) 58.00
12. 07000234 GT-038201 Wicking material (2 required) 24.00
13. 06001461 Elbow, white nylon, 1/2” x 1/2” 2.00
14. 06001345 GT-031716 Tubing, drain, clear plastic, 1/2” ID x 5/8” OD, per foot 1.45
15. 08000074 GT-031532 Base, condensing unit 30.00
16. 06001397 GT-033000 Automatic defrost timer, 6hr. 32.00
17. 06001313 GT-031400 Condensing unit power cord 20.00
06001614 GT-032510 Cap tube 110” X .054 20.00
18. 06001384 GT-032501 Accumulator, suction line 40.00
6
7
18

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 800.838.0888 / 989.752.4444 • www.glastender.com 15
7
2
14
8
9
6
5
10
12
11
15
BB36, BB60, nD52, & kc52* coMPressor anD conDenser
relateD Parts for enDWall MoDels
4
313
Part no. olD Part no. DescriPtion Price
1. 06001439 GT-035014 1/3 HP Tecumseh compressor, R134a $435.00
2. 09000481 GT-032210 Start capacitor for 1/3 HP Tecumseh R134a compressor 10.00
3. 09000479 GT-034114 Relay for 1/3 HP Tecumseh R134a compressor 20.00
4. 09000480 GT-031211 Overload protector for 1/3 HP Tecumseh R134a compressor 11.50
5. 06001449 GT-035114 Condenser fan motor 95.00
6. 08000081 GT-032801 Condenser fan blade assembly 13.00
7. 06001319 GT-031512 Condenser fan motor mounting bracket 5.00
8. 08000076 GT-032601 Condenser coil 220.00
9. 08000075 GT-032307 Fan shroud, condenser 11.00
10. 06004028 Filter dryer with service port 25.00
11. 06000155 Condensate pan 48.00
12. 07000234 Wicking material 24.00
13. 06001350 GT-031732 Tubing, drain, clear plastic, per foot, 3/4” ID 3.50
14. 06000845 GT-031539 Base, condensing unit 22.00
15. 06001615 GT-033013 Automatic defrost timer 4hr. 32.00
16. 06001313 GT-031400 Condensing unit power cord 20.00
06001673 GT-031809 Capillary tubing 48” X 0.036” (prior to Serial #134-106565-F) 10.00
09000527 Capillary tubing 65” X 0.049” (Serial #134-106565-F and after) 20.00
17. 06001384 GT-032501 Accumulator, suction line 40.00
* KC52 production began with serial number 134099618N.
16
1
17

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 800.838.0888 / 989.752.4444 • www.glastender.com
16
BB84, BB108, nD72, nD92, kc72*, & kc84* coMPressor
anD conDenser relateD Parts for enDWall MoDels
7
2
17
14
8
9
6
5
10
16
12
11
15
4
3
13
Part no. olD Part no. DescriPtion Price
1. 07000173 GT-035008 1/3 HP Embraco compressor, R404a $450.00
2. 07000151 GT-032203 Start capacitor for 1/3 HP Embraco R404a compressor 25.00
3. 06001675 GT-034103 Relay for 1/3 HP Embraco R404a compressor 15.00
4. 07000127 GT-031205 Overload protector for 1/3 HP Embraco R404a compressor 12.00
5. 08000085 GT-035106 Condenser fan motor 110.00
6. 08000081 GT-032801 Condenser fan blade assembly 13.00
7. 06001319 GT-031512 Condenser fan motor mounting bracket 5.00
8. 06001393 GT-032619 Condenser coil 230.00
9. 08000075 GT-032307 Fan shroud, condenser 11.00
10. 06004028 Filter dryer with service port 25.00
11. 06000155 Condensate pan 48.00
12. 07000234 Wicking material 24.00
13. 06001350 GT-031732 Tubing, drain, clear plastic, 3/4” dia, per foot 3.50
14. 06000845 GT-031539 Base, condensing unit 22.00
15. 06001615 GT-033013 Automatic defrost timer 4hr. 32.00
16. 06001313 GT-031400 Condensing unit power cord 20.00
06001676 GT-031810 Cap tube 84” x .049 20.00
17. 06001384 GT-032501 Accumulator, suction line 40.00
*KC72 Endwall conguration production began with serial number 404103097N.
*KC84 Endwall configuration production began with serial number 404103109N.
1
Other manuals for LP60
1
This manual suits for next models
33
Table of contents
Other Glastender Accessories manuals
Popular Accessories manuals by other brands

Rice Lake
Rice Lake iRite 920i Operation manual

Fiamma
Fiamma F1 Repair instructions

BAT
BAT Base Lite Use and maintenance manual

ETI
ETI Snow Owl Operation manual

PCB Piezotronics
PCB Piezotronics 352B70 Installation and operating manual

PCB Piezotronics
PCB Piezotronics 103B11 Installation and operating manual