FREEFIT INSTALLATION GUIDE
8 globalfurnituregroup.com
•Pageglobalcontract.com 9
• August 2014
GLOBALContract
Wheel Controls
How to set memory:
Run/Drive the table to the position you will store,
sitting or standing.
(This device have 5 memories position memories)
Press menu button + “stand” icon 1 time to come
to set memory menu.
Calibrate:
Measure the distance between the floor and the top
of the table sheet.
Press menu button + “stand” icon 2 times to come
to calibrate menu.
Use arrow up and down to navigate to set memory
setting.
Press Menu/Enter, and the value are stored.
The display confirm by flashing 3 times and then
returns to normal mode.
Press Menu/Enter to confirm
Press Menu/Enter to confirm
Press Menu/Enter, and the value are stored.
Press Menu/Enter, and the value are
stored.
Adjust the figures to the selected value with the
arrows up or down.
1
5
CAL
28
.
0
Upper limit:
Set the upper limit if there are limited
space in height.
Press menu button + “stand” icon 3
times to come to set memory menu.
Units:
Choose between metric or imperial
system.
Press menu button + “stand” icon 5
times to come to set memory menu.
Error codes:
Reset Away:
Press menu button + “stand” icon 6
times to come to set memory menu.
Lower limit:
Set the lower limit if there are device/
equipment which could create a risk
of pinching or risk for table damages.
Press menu button + “stand” icon 4
times to come to set memory menu.
Adjust the figures to the chosen level
with the arrows up or down.
Press Menu/Enter to confirm. Press Menu/Enter to confirm.
1. Hard stop
2. Back off
3. Soft top
4. Waiting for button
5. Waiting for button release.
6. Motor lost
Overheating. Thermometer flashing,
wait 10 minutes for motor cooling.
Adjust the figures to the chosen level
with the arrows up or down.
Adjust the figures to the chosen level
with the arrows up or down.
Press Menu/Enter, and the value are
stored.
Press Menu/Enter, and the value are
stored.
Press Menu/Enter, and the value are
stored.
Press ‘down” and hold until the columns
have gone to the lowest position.
Do reset if any parts have been changed
of if you discover interference between
the columns.
Please note that the figures count
from the table top surface.
Please note that the figures count from
the table top surface/ calibrated level.
UL
50
.
0
LL
27
.
5
UN
RES
3
Using Controls
Calibrate
If the height reading displays incorrect height, the
height from the table top needs to be
calibrated.
Measure the distance between the floor and the top
of the table top.
Press and hold M button for at least 8
seconds...
--- ...until three dashes are displayed
Release the M button
CAL Use the Up or Down button to
navigate to CAL (Calibrate)
Select by pressing the M button
or Change the current height reading by using
the Up or Down button to the measured height
Store the current height reading and return to
Menu by pressing the M button
Upper Limit
Set an Upper Limit when planning over-head storage
Press and hold M button for at least 8
seconds...
--- ...until three dashes are displayed
Release Release the M button
U . L . Use the Up or Down button to
navigate to U.L. (Upper Limit)
Select by pressing the M button
or Calibrate Upper Limit by using the Up or
Down buttons
Select value and return to Menu by pressing
the M button
Lower Limit
Set a Lower Limit when planning storage under the table
Press and hold M button for at least 8
seconds...
--- ...until three dashes are displayed
Release Release the M button
L . L . Use the Up or Down button to navigate to L.L
(Lower Limit)
Select by pressing the M button
or Calibrate Lower Limit by using the Up or
Down button
Select value and return to Menu by pressing
the M button
Change between metric or imperial units
Press and hold M button for at least 8
seconds...
--- ...until three dashes are displayed
Release Release the M button
Use the Up or Down button to navigate to
Un (Units).
Select by pressing the M button
CM OR “
Choose CM (centimeter) or “ (inch) with the Up
or Down button
Select value and return to Menu by pressing
the M button
Performing a Forced Reset
If Standard Reset (page 6) does not initiate
a reset, perform a Forced Reset
Press and hold M button for at least 8
seconds...
--- ...until three dashes are displayed
Release the M button
RES Use the Up or Down button to navigate to
RES. (Reset)
Select by pressing the M button
Activate Reset/Homing by
pressing the Down button
Software Version
Display Software Version
Press and hold M button for at least 8
seconds...
--- ...until three dashes are displayed
Release Release the M button
SOF Use the Up or Down button to navigate to SOF
(Software Version)
Select by pressing the M button
Software Version
displayed
Software Version will appear on the display
Return to Menu by pressing the M button