5221895A
Diagram 3
GAS
SERVICE
COCK
HOT
WATER
OUT
COLD
WATER
SUPPLY IN
HEATING
FLOW
HEATING
RETURN
LEVER (OPEN)
COLD WATER
SUPPLY IN/OUT
Instructions for Use
4. Open a hot water tap, check that water flows, then close it.
5. Ifyouareinanydoubtabouttheboilerbeingfilled withwater
contact your installation/servicing company or the local gas
company.
6. Check that the electrical supply to the boiler is ON at the
external isolator.
7. Check lockout light, refer to boiler safety cutoff reset button.
8. Set the switch “B”to 1 situated on the control fascia.
9. Set the summer / winter button “J”, light “L”or “K”will
illuminate.
10. Set “C”, clock/timer (if fitted) and any remote controls as
required.
11. Check the lights “D”and “E”are illuminated on the control
fascia.
Close the controls cover door.
Incertaincircumstances, asurgein water pressuremay cause
the appliance to operate momentarily, this will be indicated by
the pump starting and the fan speed increasing. This is quite
normal.
Domestic Hot Water Temperature
The sanitarywatertemperature controlknob“M”, see diagram
4, willcontrolthedesiredtemperatureofthewateruntiltheflow
exceeds the capability of the boiler to give the required
temperature rise.
Thenthetemperatureisdeterminedbycontrollingthehotwater
flow from the tap ie: reduce flow - increase temperature
increase flow - reduce temperature
NOTE : The mains incoming water temperature in the winter is
lower than in the summer.
SLOT (OPEN)
GAS SERVICE
COCK
LEVER (OPEN)
HEATING
FLOW/ RETURN
7013
SAFETY VALVE
DISCHARGE PIPE POSITION
Summer / Winter Selector Button
Adjustthecentralheatingwatertemperaturecontrolknob“N”to
desired setting.
Forcentralheatingsetbutton“J”toWinterlight“K”willilluminate.
The main burner will light. The burner ON light “D”will
illuminate.
When the heating is controlled by a room thermostat and/or a
time switch, button “J”must be set to Winter light “K”will
illuminate.
If a hot water tap is opened while the boiler is on for heating,
priority will be given to hot water.
Toturntheheatingoffforshortperiods,setbutton“J”tosummer
“Off”light “L”will illuminate.
To turn on again set button “J”to winter “On”, light “K”will
illuminate.
To Turn the Boiler Off
To turn the boiler off, set switch "B" to O.
To turn on again follow the operating instructions.
Maintenance and Servicing
To ensure the continued efficient and safe operation of the
appliance it is recommended that it is checked and serviced as
necessary at regular intervals. The frequency of servicing will
depend upon the particular installation conditions and usage,
but in general once a year should be enough.
If this appliance is installed in a rented property there is a duty
of care imposed on the owner of the property by the current
issue of the Gas Safety (Installation and Use) Regulations,
Section 35.
Servicing/maintenance should be carried out by a competent
person in accordance with the rules in force in the countries of
destination.
To obtain service, please call your installer or Heatcall (Glow-
worm’s own service organisation) using the telephone number
behind the controls cover door.
Please be advised that the ‘Benchmark’logbook should be
completed by the installation engineer on completion of
commissioning and servicing.
All CORGI Registered Installers carry a CORGI ID card, and
have a registration number. Both should be recorded in your
boilerLogbook. YoucancheckyourinstallerisCORGIregistered
by calling CORGI direct on :- 01256 372300.
Clearances
The boiler requires a clearance in front, below and at the sides
ofthecasingforsafety,servicingandmaintenanceaccess,see
diagram 2.1.
Protection Against Freezing
Theboilerhasa2stagebuiltinfrostprotection. Providedpower
and gas are available and there is adequate pressure in the
system,ifthewatertemperaturewithintheappliancefallsbelow
10oC approx. the pump only will come on. If the water temp
continues to fall to 6oC approx. the main burner will fire at min
rateuntilthewaterintheapplianceisgreaterthan15oCapprox.
This is a separate function to any remote frost protection fitted.