Goldair GHL425W User manual

For models: GHL425W, GHL425S
Heat/Light/Vent –4 Light
with LED Centre Bulb
OPERATING INSTRUCTIONS

Thank you for choosing GOLDAIR. Your GOLDAIR Bathroom Heat/Light/Vent has been designed and
manufactured to high standards of engineering. With proper use and care, as described in this leaflet,
you can expect years of service. Please read these instructions carefully.
GENERAL CARE AND SAFETY GUIDE
•Please read all instructions carefully before using your Heat/Light/Vent.
•Keep instructions for future reference.
•Use only the voltage specified on the rating plate of the appliance.
•Do not cover or restrict airflow as the appliance may overheat and become a fire risk.
•Do not cover heat lamps, or inlet of airflow by placing these areas of the appliance against any
surface.
•Do not mount appliance close to any heat source.
•Do not operate in areas where petrol, paint or other flammable liquids are used or stored.
•Do not use the appliance to dry clothes.
•Do not insert or allow foreign objects to enter any point of the appliance, as this may cause an
electric shock, fire or damage to the appliance.
•Do not immerse in liquid or allow liquid to run into the interior of the appliance, as this could create
an electrical shock hazard.
•Do not operate after the appliance malfunctions, has been dropped/damaged in any manner.
•Do not operate the appliance with wet hands.
•Use this appliance only as described in this manual. Any other use is not recommended by the
manufacturer may cause fire, electric shock or injury.
•Do not use this appliance in a window as rain may cause electric shock.
•Do not connect the appliance to the electrical supply until completely assembled.
•This appliance is intended for household use only and not for commercial or industrial use.
•This appliance is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilities, or lack of experience or knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible for their safety.
•Young children should be supervised to ensure they do not play with the appliance.
HEAT/LIGHT/VENT INSTRUCTIONS

GENERAL NOTES
This Goldair product is designed only to be used as a fixed Heat/Light/Vent product, installed into the
ceiling. If the product is installed or used for any other purpose the warranty will be void.
Installation of this product must be completed by a registered electrician.
Handle product with care, remove the bulbs during installation.
The unit must be located and installed in accordance with the AS/NZS 3000:2007 and any local
regulation information for mounting in damp areas (please consult your local electrician for
information).
The unit can be installed in any room that requires direct radiant heating and circulated air flow such as
bathrooms, ensuites, laundries, etc.
The unit must be installed in flat ceilings with a minimum height of 2 metres from the floor.
Do not install the unit directly above shower or bath recesses or enclosures.
The unit must not be installed in a position where water may splash onto the heat lamps.
At least 220mm height clearance in the ceiling cavity is required to ensure sufficient ventilation for
moisture to disperse.
The unit must also be installed at least 400mm away from the walls.
For maximum efficiency to remove steam and odours, there must be an adequate air flow within the
room. To obtain maximum air flow ensure there is a gap under doors or open windows slightly. A good
test for this is that the fan should not change speed (or sound) when you close or open the bathroom
door.
The unit can be connected to a lighting or power circuit if loading permits. All electrical work must be
carried out by a registered electrician in accordance with AS/NZS 3000:2007 (please consult your local
electrician for information). A three gang switch is included to so the user can independently switch the
Ventilation, Heat and Light on and off. This needs to be installed in a position where it cannot be
reached from the bath or shower.
Heat lamps and light bulbs supplied with the unit are test bulbs only, these are not covered under the
product warranty.
HEAT/LIGHT/VENT INSTRUCTIONS

HEAT/LIGHT/VENT INSTRUCTIONS
USER INSTRUCTIONS
Your Heat/Light/Fan unit comes with a wall switch included. Once wired correctly by your electrician
you need to simply follow the below instructions.
•To turn the centre light bulb on press the “LIGHT” switch down (and up to turn off).
•To turn the ventilation fan on press the “FAN” switch down (and up to turn off).
•To turn 2 heat lamps on press one of the “HEAT” switches down (and up to turn off).
•To turn all 4 heat lamps on press both of the “HEAT” switches down (and up to turn off).
Air Flow Requirements:
For maximum efficiency to remove steam and odours, there must be an adequate air flow within the
room. To obtain maximum air flow ensure there is a gap under doors or open windows slightly. A good
test for this is that the fan should not change speed (or sound) when you close or open the bathroom
door.
Important Note:
Always turn the fan on when using the heat lamps to minimise any undue heat build up
in the unit.

INSTALLATION INSTRUCTIONS
1.The unit may be mounted either between joists using the inbuilt clip fasteners or against a joist using
a screw through the flange plate. The approximate cut-out size of the unit is 295 x 295mm.Please note
this is only an approximate measurement and any installation would require a measurement against
the physical product to ensure the best fit.Mark the ceiling with a pencil showing the area of ceiling to
be cut.
IMPORTANT NOTE: Goldair takes no responsibility for those instances where the physical product is not
measured first before the hole is cut in the ceiling.
2.Before commencing cutting ensure that the area behind the intended location is clear of all cables,
pipes and joists. Once clear, cut out the section along the previously marked lines.
3.Remove the lamps from the housing by unscrewing them anticlockwise. Then remove the decorative
fascia from the housing by removing the spring clips that hold it in place.
4.Insert the unit into the hole being sure to pull the side springs inward so that the body can pass
through the hole without damaging the plaster. Ensure that the unit is held securely in place by clips. It
is essential that additional screws (not supplied) are used to aid holding the unit in the ceiling. Screw
holes are provided in the flange for this purpose. 2 strips of timber (one on each side) should be placed
behind the holes inside the ceiling to give the screws something to anchor to and to provide some
reinforcing. Do not secure the unit at this time.
5.Remove the unit from the ceiling and connect the wiring to the terminal block as per the wiring
diagram. This terminal block is on one corner of the back of the unit.
6.Insert the unit into the hole and secure as detailed in point 4 above.
7.Hold the fascia against the body of the appliance and the ceiling, then attach the securing spring clips
to hold the fascia in place.
8.Now screw in the 275W heat lamps provided into the lamp holder through the holes provided in the
fascia. The globes should be screwed in firmly to ensure a good electrical contact but don’t over tighten.
Fit the small centre light bulb in the same way ensuring that it is positioned centrally.
IMPORTANT NOTE: Over tightening of heat lamps or light bulbs may result in damages to the lamp
holders or lamps, take care when removing and replacing heat lamps/bulbs
.
HEAT/LIGHT/VENT INSTRUCTIONS

WIRING DIAGRAM
HEAT/LIGHT/VENT INSTRUCTIONS
ELECTRICAL INSTALLATION
IMPORTANT NOTE: All electrical work and installation of this product must be performed
by a registered electrician in accordance with AS/NZS 3000:2007.
Note: The unit is fitted with a safety thermal switch which will activate the
fan to cool the unit if the heat generated by the heat lamps exceeds a
certain level.
It is imperative that this feature is enabled.
Ensure power to the circuit to be used has been isolated at the power board before
carrying out any electrical work.
Technical Specifications:
220-240VAC 50/60Hz
1131W (Max)

SPARE PARTS
If for any reason you require spare parts, please contact Goldair customer services in the first instance
Replacement Heat lamps and light bulbs can be purchased from your local retailer. Goldair recommends
the use of Elite heat lamps and light bulbs (please note these items are not covered under warranty)
SUPPORT AND TECHNICAL ADVICE
North Shore City, Auckland, New Zealand
Monday –Friday 8am-5pm
Phone: 0800 232 633
Website: www.goldair.co.nz
HEAT/LIGHT/VENT INSTRUCTIONS

Your Goldair product has been inspected, tested and is guaranteed subject to the following for a
period to one year from the date of purchase against defects in workmanship and materials. During
this period, such defects will be rectified by repair or replacement of the product purchased. Your
product contains no user serviceable components and this warranty becomes invalid if in our opinion
the product has been misused, abused, incorrectly installed, tampered with, not installed by a
registered electrician, connected to an electrical supply not corresponding with the name plate
specification, or subjected to power surges. The warranty does not include heat lamps, light bulbs
and any labour or other associated expense that may be involved in removal or installation of the
product. Normal wear and tear is expressly excluded.
If your Goldair product fails to operate satisfactorily, please contact Goldair customer service in the
first instance, otherwise return it to the retailer from whom it was purchased. To obtain a repair or
replacement product under this warranty, you will need to produce satisfactory evidence of date of
purchase. The completed warranty and purchase receipt must be presented with the product. The
warranty should be filled out at the time of purchase. It is in your interest to make sure this is done.
If the product is to be replaced (cannot be repaired) then that replacement will be of the same or
similar product or accessory excluding packaging, instruction card etc. Where a replacement product
is supplied, this shall be guaranteed for the balance of the original warranty period.
Any model that is no longer available will be replaced by a model of a value and with such features
as we consider appropriate in the circumstances. Goldair Ltd is not responsible for freight forwarding
charges, losses or damage in transit.
If service is required after the warranty period has expired, the product should be returned to a
qualified electrical technician. Service outside of the warranty period will be at your cost.
Consumers Guarantee Act (1993).
In accordance with the above act consumers are advised that: The manufacturer does not undertake
that repair facilities and parts are necessarily available for this product.
If any of the provisions of the foregoing are contrary to any relevant legislation, then that provision
shall be deemed to be excluded from the warranty and the rest of the provisions will continue to
apply.
ONE YEAR WARRANTY
IMPORTANT: PLEASE RETAIN THIS WARRANTY CARD
NAME:
ADDRESS:
PURCHASED FROM:
SUBURB:
DATE OF PURCHASE:
NAME OF PRODUCT:
MODEL No:
This manual suits for next models