Goldline AQL-BASE-RF Operating instructions

Aqua LogicAqua Logic
Aqua LogicAqua Logic
Aqua Logic
Base Receiver
Installation/Operation Manual
for model
AQL-BASE-RF
LDLINE
CONTROLS INC.
G
North Kingstown, RI USA
www.goldlinecontrols.com
®

Compatibility
This product is compatible with allAqua Logic controls operating software revision
r1.10 or higher. To verify the software level of your Aqua Logic control: Press the
Menu button (possibly multiple times) until “Diagnostic Menu” is displayed. Next,
press the “>” or “<“ keys (possibly multiple times) until the main and display soft-
ware revision levels are displayed (the “main” rev should be r1.10 or higher).
If the software revision level is less than r1.10 contact the Goldline Technical Service
Dept. from Monday through Friday, 8AM to 8PM Eastern at 888-921-7665 for infor-
mation on upgrades.
ThisAquaLogic base receivercan communicate withtheAqua Logic spa-sideremote
(AQL-SPASIDE-RF) and also the wireless in-house remote display/keypads (AQL-
REMOTE-RF-PS-4/8/16).
1

Installation
Installation is very easy and should just take a few minutes.
Disconnect power and then remove the panel from theAqua Logic control unit. Re-
move the knock-out on the upper left side of theAqua Logic main unit and mount the
RF base station. Secure the base receiver in place by firmly tightening the nut from
inside theAqua Logic unit. Lastly, plug the pigtail cable into the “wireless connector”
connector on theAqua Logic main circuit board.
Base Receiver
(AQL-BASE-RF)
Tighten nut
Aqua Logic
Main PCB
Connector for
Base Receiver
2

Operation
Every Base Receiver is manufactured with a unique ID code. This allows private,
secure communication with all of your remote devices while ignoring any signals
transmitted by other wireless devices including any otherAqua Logic controls in the
neighborhood.
IMPORTANT: Before tryingto useany remote device: Youmust "teach" thecorrect
ID code to the remote device so it knows which base receiver to communicate with.
Refer to theAqua Logic Operation Manual or the manual for your remote device for
"teaching" instructions .
TheAqua Logic Base Receiver and remote devices are programmed with a sophisti-
cated protocol that automatically switches frequencies if other devices are interfering.
In the unlikely event that it can not find a usable frequency, it may be necessary to
change channels. Refer to theAqua Logic Operation Manual for instructions.
3

Troubleshooting
If you believe that your system is not operating properly or if you have a general
question regarding system operation, you may call the Goldline Technical Service
Dept. from Monday through Friday, 8AM to 8PM Eastern at 888-921-7665.
1. Can’t find the “Teach Wireless” display: Press the “menu” button (possibly
more than once) until “Settings Menu” is displayed. Next, press the “<“ or “>”
buttons (possibly more than once) until “Teach Wireless” display appears. If you
go through all of the displays without ever seeing the "Teach Wireless" and you
get to the point where “Settings Menu” appears again, then this means that the
Aqua Logic control unit is not communicating with the Base Receiver. Check
that the 4 wire cable from the base receiver is plugged into the “wireless connec-
tor” on the main printed circuit board (refer to the Installation section for connec-
tion diagram). If this connector is already plugged in (for more than 30 seconds),
then call Goldline Technical Service for assistance.
2. “TeachWireless” failed: Ensure that the remote is powered when pressing the
button. This is indicated by a single flash on the LED on the spa-side remote or
a message on the display of the in-house remotes. If the remote is powered, then
the next most likely cause is that the distance between the base receiver and the
remote is too great—try moving the remote closer to the receiver. Lastly, there
may be other equipment in the neighborhood that is using the same frequency.
To see if this is the case, go to the Settings Menu/Wireless Channel and select
another channel. Note that after you change the channel you will have to “re-
teach” every wireless remote device in the system.
3. Unreliable communicationwith remotedevices: The most likely cause is that
the distance between the base receiver and the remote is too great—try moving
the remote closer to the receiver. Lastly, there may be other equipment in the
neighborhood that is using the same frequency. To see if this is the case, go to the
Settings Menu/Wireless Channel and select another channel. Note that after you
change the channel you will have to “re-teach” every wireless remote device in
the system.
4. No communicationwithremotecontrols: Try the “TeachWireless” procedure
to ensure that the remote knows the ID code of the base receiver and also what
channel to communicate on. If this procedure is not successful, then refer to the
“Teach Wireless” failed section above.
4

5
Aqua RiteAqua Rite
Aqua RiteAqua Rite
Aqua Rite®, Aqua LogicAqua Logic
Aqua LogicAqua Logic
Aqua Logic®&
Aqua TrolAqua Trol
Aqua TrolAqua Trol
Aqua Trol®Limited Warranty
This warranty statement is applicable to all Aqua Rite®Aqua Logic and Aqua Trol®units with
product date codes of January 1, 2002 and after, and supersedes all warranty statements dated
prior to January 1, 2002. This Limited Warranty applies only to Aqua Rite®Aqua Logic and
Aqua Trol®Electronic Chlorine Generators. Refer to the appropriate limited warranty state-
ment for all other Goldline Controls products.
When installed on private, single-family residential swimming pools or spas within the
USA and Canada: Goldline Controls, Inc. (Goldline) warrants Aqua Rite®Aqua Logic and
Aqua Trol®to be free from defects in material or workmanship, under normal use and service
on private, single-family residential swimming pools within the USAand Canada for five
years from date of the initial system installation, provided it is installed and maintained in
accordance with the installation instructions and specifications. If written proof of the date of
the initial system installation is not provided to Goldline, the manufacturing datecode on the
Aqua Rite®, Aqua Logic and Aqua Trol®electronics unit will be the sole determinant of the date
of the initial system installation.
If a product is defective, in workmanship or materials and is removed within 3 years (36
months) after the date of the initial system installation and is returned freight prepaid, Goldline
Controls will, at its option, either repair or replace the defective product and return it freight
prepaid. For years 4 and 5, Goldline, at its option, either repair or replace the defective prod-
uct and will charge 60% of the current list price for such repairs or replacements, plus shipping
charges. Goldline will not assume any of the cost incurred in removal or reinstallation of the
product.
When installed on all other pools or spas
The Limited Warranty for all other pools, including but not limited to commercial pools,
public pools, and pools located outside the USA and Canada, is one year from date of the
initial system installation, provided it is installed in accordance with the installation instruc-
tions and specifications. If written proof of the date of the initial system installation is not
available, the manufacturing date-code on the Aqua Rite®, Aqua Logic, or Aqua Trol®electron-
ics unit will be the sole determinant of the date of the initial installation.
If a product is defective, in workmanshipor materials and is removed within 1 year (12months)
after the date of the initial system installation, and is returned freight prepaid, Goldline will, at
its option, either repair or replace the defective product and return it freight prepaid. Goldline
will not assume any of the cost incurred in removal or reinstallation of the product.
Replacement parts
If a purchased replacement part is defective, in workmanship or materials and is removed
within 1 year (12 months) after the date of purchase, and is returned freight prepaid, Goldline
will, at its option, either repair or replace the defective purchased part and return it freight
prepaid.
Warranty exclusions
1. Material supplied or workmanship performed by others in the process of installation
2. Damage resulting from improper installation.
3. Problems resulting from failure to operate the products in accordance with recommended
instructions contained in product’s owners manual.
4. Problems resulting from failure to maintain pool water chemistry in accordance with rec-
ommended levels.
5. Problems resulting from installing less than one Aqua Rite®orAqua Logic unit per 40,000
gallons (25,000 gallons commercial/public pools) or one Aqua Trol unit per 18,000 gal-
lons of pool water.
6. Problems resulting from tampering, accident, abuse, negligence, unauthorized repairs or
alterations, fire, flood, lightning, freezing, external water, war, or acts of God.

6
The express warranty above constitutes the entire warranty of Goldline Controls, Inc with
respect to the Aqua Rite, Aqua Logic, and Aqua Trol products and IS IN LIEU OFALLOTHER
WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING AWARRANTY OF FITNESS
FORAPARTICULAR PURPOSE. IN NO EVENTSHALLGOLDLINE CONTROLS, INC.
BERESPONSIBLE FORANYCONSEQUENTIALORINCIDENTALDAMAGESOFANY
NATURE WHATSOEVER.
No wholesaler, agent, dealer, contractor, or other person is authorized to give any warranty on
behalf of Goldline Controls, Inc. This warranty is void if the product has been altered in any
way after leaving the factory.

North Kingstown, RI 02852 USA
092040A
LDLIN
E
CONTROLS INC.
G
© 2004 Goldine Controls, Inc
FCC Statement
(Compliance Statement, Part 15.19): This device complies with Part 15 of the
FCC Rules. Operation is subject to the following two conditions: (1)This device
may not cause harmful interference, and (2) this device must accept any interfer-
ence received, including interference that may cause undesired operation.
WARNING (Part 15.21): Changes or modifications not expressly approved by the
party responsible for compliance could void the user’s authority to operate this
equipment.
Industry Canada Statement
The term “IC” before the certification/registration number only signifies that the
Industry Canada technical specifications were met.
Interference
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC rules. These limits are designed to
provide reasonable protection against harmful interference in a residential instal-
lation. This equipment generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harm-
ful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, then the user is encouraged to try to correct the
interference by one or more of the following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and the receiver
• Connect the equipment into a power source on different circuit than the re-
ceiver.
Table of contents
Other Goldline Control Unit manuals
Popular Control Unit manuals by other brands

Apator Metra
Apator Metra E-ITN 30 user guide

Hochiki
Hochiki DCP-FRCME-EEPROM installation instructions

Genebre
Genebre 5985 Installation, operation and maintenance manual

GRAUPNER
GRAUPNER 33600 manual

Staubli
Staubli CombiTac direqt CTD-NET Assembly instructions

Flo-Tite
Flo-Tite F300 Installation operation & maintenance

Hays Fluid Controls
Hays Fluid Controls 2540 Series Installation, operation & maintenance instructions

Burkert
Burkert 0420 operating instructions

Veripos
Veripos LD6 installation manual

HVAC Controls
HVAC Controls iO-ESP-400 Installation & operation instructions

Monacor
Monacor PA TXA-802MT manual

Airia
Airia Lifebreath Pure Performance RNC5-HEX Homeowner's guide