GoWISE USA GW22061 User manual

:110*160mm
GW22061
SIZE
GW22061

EMC Guidance
16
18
18

2.4”×1.6” (60×40.5mm)
4
83/4 -161/2
(Not included)

SYMBOL DESCRIPTION
Systolic blood pressure High pressure result
Diastolic blood pressure Low pressure result
EXPLANATION
Pulse per minute Beats per minute, BPM
Deflating CUFF air is exhausting of deflating
Memory The displayed measurement values
is from the memory.
mmHg
kPa
Measurement Unit of the blood pressure
Measurement Unit of the blood pressure
Low battery Batteries are low and need to be replaced
Irregular heartbeat
Arrhythmia
Grade The grade of the blood pressure
kPa
mmHg
Current Time Year/Month/Day, Hour/Minute

List
1.Blood Pressure Monitor
4.User manual
3. 4×AAA batteries
2.Cuff (Type BF applied part) (22~32cm)
BATTERY COMPARTMENT
(Not included)
Component list of
pressure measuring system
1 Cuff
2 Air pipe
3 PCBA
4 Pump
5 Valve
CUFF
AIR HOSE
AIR CONNECTOR PLUG
LCD DISPLAY
MEM BUTTON
Start/Stop BUTTON
SET BUTTON
AAA batteries


MINUTE
6. Repeat step 2 and 3 to set the [UNIT].
Safety Information
The below signs might be in the user manual, labeling or other component. they are
the requirement of standard and using.
Symbol for “THE OPERATION
GUIDE MUST BE READ”
Symbol for “MANUFACTURER”
Symbol for “SERIAL NUMBER”
Symbol for “TYPE B APPLIED
PARTS”
Symbol for “DIRECT CURRENT”
Symbol for “ENVIRONMENT
PROTECTION - Wast electrical
products should not be disposed of
with household waste. Please recycle
where facilities exist. Check with your
local authority or retailer for recycling
advice”

START
STOP
START
STOP

Press and hold “MEM” for 3 seconds
when the monitor is off,
START
STOP
DOWN
UP
The current No. is No 2. The corresponding
time is P.M. 10:08.
The corresponding
date is January 1st.
1.
2.

START
STOP

Put in a dry place and avoid the sunshine
Avoid the intense shaking
and collision
Using the wet clothing to remove the dirt
Avoid touching water,
clean it with a dry cloth in case.
Avoid the dusty and unstable-
temperature environment
Do not attempt to clean the reusable cuff
with water and never immerse the cuff in
water.

120~129

START
STOP
START
STOP

(Not Include) 2.4”×1.6” (60×40.5mm)
4×AAA batteries

15
WARNING: No n of this equipment is allowed.
AUTHORIZED COMPONENT
AC Adaptor
Input: 100-240V, 50-60Hz,
Output: 6V===1A
Approx. 83/4”- 161/2” (22 - 42cm)
Approx. (175g), excluding dry cells
Approx.
I n Manual
s
Accuracy
Measurement perimeter
of the upper arm
Weight
External dimensions
ingress of water
(NOT INCLUDED)
Temperature: 41°F-104°F (5℃to 40℃)
Relave humidity ≤85%
Atmospheric pressure: 86kPa to 106kPa
Temperature: -4°F-140°F (-20℃-60℃)
Relave Humidity 10%-93%
Atmospheric Pressure: 50-106 kPa
Pressure:
41°F-104°F (5℃-40℃)within±0.4kpa(3mmHg)
pulse value: ±5%
0.39lb
43.3"x43.3"x15.5"(110x110x40mm)
IPX-21
Type BF applied part
4×AAA batteries,
300mA

EMC Guidance
Table 1 Guidance and MANUFACTURER’s declaration – ELECTROMAGNETIC
EMISSIONS- for all ME EQUIPMENT and ME SYSTEMS
Guidance and manufacturer’sdeclaration – electromagnetic emissions
RF emissions
CISPR 11 Group 1
Class B
Not applicable
Not applicable
Compliance
The device is intended for use in the electromagnetic environment specified
below. The customer or the user of the device should assure that it is used in
such an environment.
Harmonic emissions
IEC 61000-3-2
Voltage fluctuations/
flicker emissions IEC
61000-3-3
RF emissions
CISPR 11
Emissions test Electromagnetic environment - guidance
The device uses RF energy only for its
internal function. Therefore, its RF
emissions are very low and are not likely
to cause any interference in nearby
electronic equipment.
Guidance and manufacturer’s declaration – electromagnetic immunity
IMMUNITY test
±6 kV contact
±8 kV air ±6 kV contact
±8 kV air
±2 kV for
power supply lines
±1 kV line(s)
to line(s)
±2 kV line(s)
to earth
<5% U
T
(>95% dip in U
T
)
for 0.5 cycle
40% U
T
(60% dip in U
T
)
for5cycles
70% U
T
(30% dip in U
T
)
for 25 cycles
<5% U
T
(>95% dip in U
T
)
for 5 s
3A/m
NOTE U
T
is the a.c. mains voltage prior to application of the test level.
Table 2 Guidance and MANUFACTURER’s declaration – electromagnetic
IMMUNITY – for all ME EQUIPMENT and ME SYSTEMS
IEC 60601 test level Compliance level
Electrostatic
discharge (ESD)
IEC 61000-4-2
Electromagnetic
environment - guidance
Floors should be wood,
concrete or ceramic tile. If
floors are covered with
synthetic material, the
relative humidity should be
at least 30%.
Power frequency magnetic
fields should be at levels
characteristic of a typical
location in a typical
commercial or hospital
environment.
3A/m
16
Power frequency
(50/60Hz)
magnetic field
IEC 61000-4-8
Voltage dips,
short interruptions
and voltage
variations on
power supply
input lines
IEC 61000-4-11
Electrical fast
transient/burst
IEC 61000-4-4
Surge IEC
61000-4-5
The device is intended for use in the electromagnetic environment specified below.
The customer or the user of the device should assure that it is used in such an
environment
±1 kV for
input/output lines
Mains power quality should
be that of a typical
commercial or hospital
environment.
Mains power quality should
be that of a typical
commercial or hospital
environment.
Mains power quality should
be that of a typical
commercial or hospital
environment. If the user of
the device requires
continued operation during
power mains interruptions,
it is recommended that the
device be powered from an
uninterruptible power supply
or a battery.
±2 kV for power
supply lines
±1 kV line(s) to
line(s)
<5% U
T
(>95% dip in U
T
)
for 0.5 cycle
40% U
T
(60% dip in U
T
)
for5cycles
70% U
T
(30% dip in U
T
)
for 25 cycles
<5% U
T
(>95% dip in U
T
)
for 5 s

17
Table 4 Guidance and MANUFACTURER’s declaration – electromagnetic IMMUNITY –
for ME EQUIPMENT and ME SYSTEMS that are not LIFE-SUPPORTING
Guidance and manufacturer’s declaration – electromagnetic immunity
IMMUNITY test
3 Vrms
3 V/m
Compliance
level
IEC 60601
TEST LEVEL
Conducted RF
IEC 61000-4-6
Radiated RF
IEC 61000-4-3 3 V/m
80 MHz to
2.5 GHz
3 Vrms
150 kHz to
80 MHz
Electromagnetic environment -
guidance
Portable and mobile RF communications
equipment should be used no closer to
any part of the device, including
cables, than the recommended
separation distance calculated from the
equation applicable to the frequency of
the transmitter.
Recommended separation distance
The device is intended for use in the electromagnetic environment specified below.
The customer or the user of the device should assure that it is used in such an environment.
where P is the maximum output power
rating of the transmitter in watts (W)
according to the transmitter manufacturer
and dis the recommended separation
distance in metres (m).
Field strengths from fixed RF
transmitters, as determined by an
electromagnetic site survey, should be
less than the compliance level in each
frequency range.
a
b
Interference may occur in the vicinity of
equipment marked with the following
symbol:
P
=d
P=d 80 MHz to 800 MHz
P=d 2.333 800 MHz to 2,5 GHz
1.167
NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic
propagation is affected by absorption and reflection from structures, objects
and people.
aField strengths from fixed transmitters, such as base stations for radio (cellular /
cordless) telephones and land mobile radios, amateur radio, AM and FM radio broad-
cast and TV broadcast cannot be predicted theoretically with accuracy. To assess the
electromagnetic environment due to fixed RF transmitters, an electromagnetic site
survey should be considered. If the measured field strength in the location in which
the device is used exceeds the applicable RF compliance level above, the device
should be observed to verify normal operation. If abnormal performance is observed,
additional measures may be necessary, such as re-orienting or relocating the device.
Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3V/m.
b
1.167
150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2.5 GHz
Table 6 Recommended separation distances between portable and mobile
RF communications equipment and the ME EQUIPMENT or ME SYSTEM –
for ME EQUIPMENT and ME SYSTEMS that are not LIFE-SUPPORTING
Recommended separation distances
between portable and mobile RF communications equipment and the device.
The device is intended for use in an electromagnetic environment in which
radiated RF disturbances are controlled. The customer or the user of the device
can help prevent electromagnetic interference by maintaining a minimum distance
between portable and mobile RF communications equipment (transmittters) and the
device as recommended below, according to the maximum output power of the
communications equipment.
Rated maximum output
power of transmitter
(W)
Separation distance according to frequency of transmitter(m)
For transmitters rated at a maximum output power not listed above, the recommended
separation distance din metres (m) can be estimated using the equation applicable to
the frequency of the transmitter, where Pis the maximum output power rating of the
transmitter in watts (W) according to the transmitter manufacturer.
NOTE 1 At 80MHz and 800MHz, the separation distance for the higher frequency
range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation
is affected by absorption and reflection from structures, objects and people.
0.01
0.1
1
10
100
0.117 0.117
0.369
1.167
3.690
11.67
0.233
0.738
2.333
7.378
23.33
P=d P=d 1.167 2.333 P=d
0.369
1.167
3.690
11.67
1.167

18
FCC STATEMENT
Note:
POTENTIAL FOR RADIO/TELELVISION INTERFERENCE (for U.S.A. only)
This product has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC rules.
Table of contents
Other GoWISE USA Blood Pressure Monitor manuals