LAVA BURNER FRONT VIEW WITH GLOWFIRE™ LOGS INSTALLATION & OPERATION MANUAL
GRANDCANYONGASLOGS.COM - 08_2023
GENERAL INSTRUCTIONS
5
WARNING:VENTED DECORATIVE GAS APPLIANCE: NOT A SOURCE OF HEAT; NOT FOR USE WITH SOLID FUEL.
AVERTISSEMENT: APPAREIL DÉCORATIF À GAZ VENTILÉ: PAS UNE SOURCE DE CHALEUR; NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE.
THIS APPLIANCE NEEDS FRESH AIR FOR SAFE OPERATION AND MUST BE INSTALLED SO THERE ARE PROVISIONS FOR ADEQUATE COMBUSTION AND VENTILATION AIR.
CET APPAREIL A BESOIN D'AIR FRAIS POUR UN FONCTIONNEMENT SÉCURISÉ ET DOIT ÊTRE INSTALLÉ POUR IL Y A DES DISPOSITIONS POUR UN AIR
DE COMBUSTION ET DE VENTILATION ADÉQUAT.
The installation, including provisions for combustion, ventilation air, and required minimum permanent vent opening, must conform with
National Fuel Gas Code (ANSI Z223.1/NFPA 54) and applicable local building codes.
L'installation, y compris les dispositions pour la combustion, l'air de ventilation et l'ouverture de ventilation permanente minimale requise, doit être conforme au National Fuel Gas Code
(ANSI Z223.1 / NFPA 54) et aux codes du bâtiment locaux applicables.
WARNING: This gas appliance must not be connected to a chimney fuel servicing a solid fuel burning appliance.
AVERTISSEMENT: Cet appareil à gaz ne doit pas être raccordé à un combustible de cheminée desservant un appareil à combustible solide.
WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause property damage, personal injury, or loss of life. Refer to the owner’s information manual
provided with this appliance. Installation and service must be performed by a qualified installer, service agency, or the gas supplier.
AVERTISSEMENT: Une installation, un réglage, une modification, un service ou un entretien inappropriés peuvent provoquer des dommages matériels, des blessures corporelles ou
la mort. Reportez-vous au manuel d’information du propriétaire fourni avec cet appareil. L'installation et l'entretien doivent être effectués par un installateur qualifié, une agence de
service ou le fournisseur de gaz.
WARNING: For installation in a solid-fuel burning fireplace only. The fireplace chimney must have a permanent vent opening to atmosphere of
not less than 70 square inches, or as determined from the manufacturer’s installation instructions.
AVERTISSEMENT: Pour installation dans un foyer à combustible solide uniquement. La cheminée du foyer doit avoir une ouverture de ventilation
permanente vers l’atmosphère d’au moins 70 pouces carrés, ou tel que déterminé à partir des instructions d’installation du fabricant.
DO NOT REMOVE THIS LABEL
See installation & operating instructions for this model.
Contact local building officials about restrictions and
installation specifications in your area.
DATE
OF MFG. SERIAL
#
MODEL: LAFV EN 18 24 30 36
HIGH BTU/HR (kW): 45,000 (13.19kW) 56,000 (16.41kW) 75,000 (21.98kW) 86,000 (25.20kW)
NG Models
Altitude
Input
Reduced Input
P4
Manifold Pressure: 3.5" w.c.(NG)
Minimum Supply Pressure: 5" w.c. (NG)
Maximum Supply Pressure: 10.5"* w.c. (NG)
Pression au Collecteur: .87wPA d’une colonne d’eau (GN)
Pression d’Alimentation Min.: 1.25wPA d’une colonne d’eau (GN)
Pression d’Alimentation Max.: 3.5wPA ** d’une colonne d’eau (GN) **
Maximum inlet pressure not to exceed 10.5".
Minimum clearance to combustible materials: Top, sides & back:
For non-combustible framing and finishing materials, see installation
manual.
LP Models
Élévation
Alimentation / Alimentation Réduite
P4
Manifold Pressure: 10.5" w.c. (LP)
Minimum Supply Pressure: 11" w.c. (LP)
Max. Supply Pressure: 14"* w.c. (LP)
Pression au Collecteur: 2.40wPA d’une colonne d’eau (LP)
Pression d’Alimentation Min.: 2.74wPA d’une colonne d’eau (LP)
Pression d’Alimentation Max.: 3.5wPA * d’une colonne d’eau (LP)
** Pression d’alimentation maximale ne devait pas dépasser
3.5wPA. Dégagement minimum par rapport aux matériaux
combustibles : Dessus, côtés et arrière : Pour les matériaux de
charpente et de finition non combustibles, voir le manuel
d'installation.
MANIFOLD PRESSURE:
ELECTRICAL RATING: 3V
GAS TYPE: NATURAL GAS ONLY
ANSI-Z21 60-2017
CSA 2.26-2017
Decorative gas appliances
for installation in solid-fuel
burning fireplaces.
REPORT #
F23-187
BATTERY-DEXEN
MODEL: LAFV EP 18 24 30 36
HIGH BTU/HR (kW): 38,000 (11.14kW) 54,000 (15.83kW) 76,000 (22.738kW) 85,000 (24.91kW)
3515 E. Atlanta Ave. Phoenix, AZ 85040
07-00070
TESTED &
LISTED BY:
WARNING:VENTED DECORATIVE GAS APPLIANCE: NOT A SOURCE OF HEAT; NOT FOR USE WITH SOLID FUEL.
AVERTISSEMENT: APPAREIL DÉCORATIF À GAZ VENTILÉ: PAS UNE SOURCE DE CHALEUR; NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE.
THIS APPLIANCE NEEDS FRESH AIR FOR SAFE OPERATION AND MUST BE INSTALLED SO THERE ARE PROVISIONS FOR ADEQUATE COMBUSTION AND VENTILATION AIR.
CET APPAREIL A BESOIN D'AIR FRAIS POUR UN FONCTIONNEMENT SÉCURISÉ ET DOIT ÊTRE INSTALLÉ POUR IL Y A DES DISPOSITIONS POUR UN AIR
DE COMBUSTION ET DE VENTILATION ADÉQUAT.
The installation, including provisions for combustion, ventilation air, and required minimum permanent vent opening, must conform with
National Fuel Gas Code (ANSI Z223.1/NFPA 54) and applicable local building codes.
L'installation, y compris les dispositions pour la combustion, l'air de ventilation et l'ouverture de ventilation permanente minimale requise, doit être conforme au National Fuel Gas Code
(ANSI Z223.1 / NFPA 54) et aux codes du bâtiment locaux applicables.
WARNING: This gas appliance must not be connected to a chimney fuel servicing a solid fuel burning appliance.
AVERTISSEMENT: Cet appareil à gaz ne doit pas être raccordé à un combustible de cheminée desservant un appareil à combustible solide.
WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause property damage, personal injury, or loss of life. Refer to the owner’s information manual
provided with this appliance. Installation and service must be performed by a qualified installer, service agency, or the gas supplier.
AVERTISSEMENT: Une installation, un réglage, une modification, un service ou un entretien inappropriés peuvent provoquer des dommages matériels, des blessures corporelles ou
la mort. Reportez-vous au manuel d’information du propriétaire fourni avec cet appareil. L'installation et l'entretien doivent être effectués par un installateur qualifié, une agence de
service ou le fournisseur de gaz.
WARNING: For installation in a solid-fuel burning fireplace only. The fireplace chimney must have a permanent vent opening to atmosphere of
not less than 70 square inches, or as determined from the manufacturer’s installation instructions.
AVERTISSEMENT: Pour installation dans un foyer à combustible solide uniquement. La cheminée du foyer doit avoir une ouverture de ventilation
permanente vers l’atmosphère d’au moins 70 pouces carrés, ou tel que déterminé à partir des instructions d’installation du fabricant.
DO NOT REMOVE THIS LABEL
See installation & operating instructions for this model.
Contact local building officials about restrictions and
installation specifications in your area.
DATE
OF MFG. SERIAL
#
NG Models
Altitude
Input
Reduced Input
P4
Manifold Pressure: 3.5" w.c.(NG)
Minimum Supply Pressure: 5" w.c. (NG)
Maximum Supply Pressure: 10.5"* w.c. (NG)
Pression au Collecteur: .87wPA d’une colonne d’eau (GN)
Pression d’Alimentation Min.: 1.25wPA d’une colonne d’eau (GN)
Pression d’Alimentation Max.: 3.5wPA ** d’une colonne d’eau (GN) **
Maximum inlet pressure not to exceed 10.5".
Minimum clearance to combustible materials: Top, sides & back:
For non-combustible framing and finishing materials, see installation
manual.
LP Models
Élévation
Alimentation / Alimentation Réduite
P4
Manifold Pressure: 10.5" w.c. (LP)
Minimum Supply Pressure: 11" w.c. (LP)
Max. Supply Pressure: 14"* w.c. (LP)
Pression au Collecteur: 2.40wPA d’une colonne d’eau (LP)
Pression d’Alimentation Min.: 2.74wPA d’une colonne d’eau (LP)
Pression d’Alimentation Max.: 3.5wPA * d’une colonne d’eau (LP)
** Pression d’alimentation maximale ne devait pas dépasser
3.5wPA. Dégagement minimum par rapport aux matériaux
combustibles : Dessus, côtés et arrière : Pour les matériaux de
charpente et de finition non combustibles, voir le manuel
d'installation.
MANIFOLD PRESSURE:
ELECTRICAL RATING: 6V
GAS TYPE: LIQUID PROPANE ONLY
MODEL: LAFV VEP 18 24 30 36
HIGH BTU/HR (kW): 38,000 (11.14kW) 54,000 (15.83kW) 76,000 (22.27kW) 85,000 (24.91kW)
LOW BTU/HR (kW): 18,000 (5.27kW) 30,000 (8.79kW) 40,000 (11.72kW) 48,000 (14.06kW)
ANSI-Z21 60-2017
CSA 2.26-2017
Decorative gas appliances
for installation in solid-fuel
burning fireplaces.
REPORT #
F23-187
BATTERY-SIT
MODEL: LAFV VEN 18 24 30 36
HIGH BTU/HR (kW): 45,000 (13.19kW) 56,000 (16.41kW) 75,000 (21.98kW) 86,000 (25.20kW)
LOW BTU/HR (kW): 30,000 (8.79kW) 35,000 (10.25kW) 45,000 (13.18kW) 55,000 (16.11kW)
3515 E. Atlanta Ave. Phoenix, AZ 85040
07-00069
TESTED &
LISTED BY:
4