10 / 24 33576_jp_V1
Programming the receiver settings
The receiver can be programmed with a suitable HoTT transmit-
ter or in connection with the SMART-BOX.
Receiver settings menu
The receiver setup menu appears in the “Telemetry“ menu under
SETTINGS / DISPLAYS or if you are using a SMART-BOX under
SETTING & DATAVIEW. How to access this menu is described
in the operating instructions supplied with your transmitter or
Smart-Box.
Low voltage warning (ALARM VOLT):
If the receiver voltage or the external voltage at channel 5 falls
below the set value, a low-voltage warning is generated by the
transmitter's RF module in the form of a "general alarm tone"
(regular beeping at a rate of approx. one beep per second) or
the "receiver voltage" speech output message.
Temperature warning (ALARM TEMP):
If the receiver temperature exceeds the set temperature, a warn-
ing is generated by the transmitter’s RF module in the form of a
"general alarm tone" (regular beeping at a rate of approx. one
beep per second) or the "receiver temperature" speech output
message.
Maximum altitude (Altitude max.) - only by No. 33577 with inte-
grated Vario:
this is where you can specify a maximum altitude. When the
model reaches this altitude, an alarm is triggered either by the
transmitter's RF module in the form of a "general alarm tone"
(regular beeping at a rate of approx. one beep per second) or
the "altitude" speech output message. Note: When the receiver
is switched on, the model's current altitude is set to 0; the dis-
played altitude is therefore the altitude relative to the launch
point.
Cycle time (CYCLE):
Cycle time (PERIOD): If your system is used exclusively with dig-
ital servos, you can set a cycle time (frame rate) of 10 ms. If your
system includes some or uses exclusively analogue servos, you
should always select 20 ms, as many analogue servos cannot
process the higher frame rate and may respond by "jittering" or
"growling".
HoTT sum signal (SUMD):
If you activate the digital sum signal at channel 6, a sum signal
containing 8 channels is present at this socket, instead of a
servo signal.
RECEIVER 2.0 < >
>ALARM VOLT 3,8V
ALARM TEMP: 70°C
Altitude max: 125m
>CYCLE: 20ms
SUMD at C6: No
Sensor at C5 No
LANGUAGE: English