S30.0.01.6C-03
4 Safety requirements
This device has been designed and tested in accordance with the safety regulations for electronic devices.
However, its trouble-free operation and reliability cannot be guaranteed unless the standard safety measures and
special safety advises given in this manual will be adhered to when using the device.
1. Trouble-free operation and reliability of the device can only be guaranteed if the device is not subjected to any
other climatic conditions than those stated under "Specification".
2. Prior to opening it, disconnect device and supply voltage source. Make sure that all parts of the device are
protected against direct touching when mounting the device and setting its connections.
3. Please always adhere to the standard safety regulations for electric devices, power systems and light-current
installations, and make sure that your national safety regulations (e.g. VDE 0100) are observed.
4. If device is to be connected to other devices (e.g. PC) the circuitry has to be designed most carefully. Internal
connection in third party devices may result in not-permissible voltages.
5. If there is a risk whatsoever involved in running it, the device has to be switched off immediately and to be
marked accordingly to avoid re-starting.
Operator safety may be at risk if:
- there is visible damage to the device
- the device is not working as specified
- the device has been stored under unsuitable conditions for a longer time.
In case of doubt, please return device to manufacturer for repair or maintenance.
6. Attention: Do NOT use this product as safety or emergency stopping device, or in any other application where
failure of the product could result in personal injury or material damage. Failure to comply with these
instructions could result in serious injury and material damage.
5 Specification
Supply voltage: 220 ... 240 VAC; 50/60Hz
Power supply: approx. 3W
Working conditions: 0 ... 50 °C, 0 ... 80 %RH (non condensing)
Storage temperature: -20 ... 70 °C
Dimensions: 70 * 112 * 45 mm (W * L * D; housing only)
Isolation voltage: up to 1.5kV RMS (for 1 min)
RS485:
Transmission mode: half-duplex
Connection: 2-pin screw-type/plug-in terminal: PHOENIX MC1.5/2-ST-3.81
Connection cable: 2-pin, twisted (recommended)
Length of line: max. 1000 meters
Baud rate: max. 115.2 kBaud
Switch back time: switch 1 on, switch 2 off: ~10ms, suitable for data transfer rate > 1200 baud
switch 1 on, switch 2 on: ~2ms, suitable for data transfer rate > 9600 baud
RS232:
Connection: 9 pin Sub-D-socket
Pin assignment: Dsub 9 Dsub 25
3 ----- 2 TxD
2 ----- 3 RxD
7 ----- 4 RTS
8 ----- 5 CTS
5 ----- 7 GND
6 ----- 6 DSR
4 ----- 20 DTR
EMC: The device corresponds to the essential protection ratings established in the Regulations of the Council for
the Approximation of Legislation for the member countries regarding electromagnetic compatibility
(89/336/EWG).
Tested in accordance with EN50081-1 and EN50082-1 for unlimited use in commercial and residential areas.
6 Disposal instructions
The device must not be disposed in the regular domestic waste.
Send the device directly to us (sufficiently stamped), if it should be disposed. We will dispose the device
appropriate and environmentally sound.