Grifco DDEB-1R User manual

RELAY EXPANSION MODULE MANUAL
PART 1 of 1
D-Drive Wall Controller
Plug In Relay Expansion Module Manual for D-Drive Wall Controller
Variable Speed / Inverter models DDI-07, DDI-12 and DDI-15
This manual should be read in conjunction with Installation Manual D-Drive Wall Control Manual (D-M-ACG-100)
Chamberlain Australia Pty Ltd
Unit 1, 75 Epping Road
North Ryde NSW 2113
Ph: 1800 GRIFCO
www.grifco.com.au
Chamberlain New Zealand Ltd
17B Arrenway Drive
Rosedale 0623 Auckland
Ph: 0800 653 667
www.grifco.co.nz
D-M-ACG-122_A

1. Safety Warnings
WARNING: THESE ARE IMPORTANT SAFETY INSTRUCTIONS
FOLLOW ALL INSTRUCTIONS AS INCORRECT INSTALLATION
CAN LEAD TO SEVERE INJURY OR DEATH
SAVE these instructions
These Relay Expansion Modules have been designed and tested to offer safe service provided it is installed,
operated, maintained and tested in strict accordance with the instructions and warnings contained in this manual.
This document is the installation manual for the Relay Expansion Modules for the D-Drive Operator Wall Controller.
The following warnings are to be considered when completing a system installation or maintenance.
WARNING
Mechanical
When you see this Safety Symbol and Signal Words on the following pages, they will
alert you to the possibility of serious injury or death if you do not comply with the
warnings that accompany them. The hazard may come from something mechanical.
• Sticking or binding doors must be repaired. Commercial doors, door springs, pulleys, brackets and their
hardware are under extreme tension and can cause serious personal injury. Do not attempt to loosen, move or
adjust them. Call for commercial door service.
• Do not wear rings, watches or loose clothing while installing or servicing a commercial door operator.
• To avoid serious personal injury from entanglement, remove all ropes connected to the commercial door before
installing the door operator.
• After the installation a final test of the full function of the system and the full function of the safety devices must
be done.
• When operating a biased-off switch, make sure that other persons are kept away.
• The operator cannot be used with a driven part incorporating a wicket door (unless the operator cannot be
operated with the wicket door open).
• Operator may become hot during operation. Appropriate clearance and/or shielding should be supplied by the
installer to ensure any cabling, wiring and/or other items cannot come in contact with the operator. If
temperature rise exceeds 50°C all fixed wiring insulation must be protected, for example, by insulating sleeving
having an appropriate temperature rating.
• Do not allow children to play with operator wall controls or remote controls. Keep remote controls away from
children.
• Permanently fasten all supplied labels adjacent to the wall control as a convenient reference and reminder of
safe operating procedures.
• Disengage all existing commercial door locks to avoid damage to commercial door. Install the wall control (or
any additional push buttons) in a location where the commercial door is visible during operation. Do not allow
children to operate push button(s) or remote transmitter(s). Serious personal injury from a closing commercial
door may result from misuse of the operator.
• Activate operator only when the door is in full view, free of obstructions and operator is properly adjusted. No
one should enter or leave the building while the door is in motion.
• The actuating member of a biased-off switch is to be located within direct sight of the door but away from
moving parts. Unless it is key operated, it is to be installed at a minimum height of 1500mm and not accessible
to the public.
• Make sure that people who install, maintain or operate the door follow these instructions. Keep these
instructions in a safe place so that you can refer to them quickly when you need to.
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety. Children should be supervised to
ensure that they do not play with the appliance.
• Use the operator for its intended purpose. This product is for indoor use only.
• Automatic Drive - Keep away from the area of the door as it may operate unexpectedly.
• Ensure that entrapment when operating the door in the open direction is avoided.
• If the operator is installed at a height less than 2.5 metres from floor level or any other level from which the
operator can be accessed (e.g. mezzanine) the installer is responsible to fit guards as appropriate to prevent
access to moving mechanisms to reduce risk of entrapment.
WARNING
Electrical
When you see this Safety Symbol and Signal Words on the following pages, they will alert you
to the possibility of serious injury or death if you do not comply with the warnings that
accompany them. The hazard may come from electric shock.
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified
persons to avoid a hazard.
• Installation and wiring must comply with local building and electrical codes. Connect the power supply cord only
to properly earthed mains.
• Moisture and water can destroy the electronic components. Make sure under all circumstances that water
moisture or storage moisture cannot penetrate the electronics. The same applies for openings and cable entries.
• An electrician must disconnect electric power to the commercial door operator before making repairs or
removing covers.
CAUTION When you see this Signal Word on the following pages, it will alert you to the possibility of
damage to your commercial door and/or the commercial door operator if you do not comply
with the cautionary statements that accompany it.

D-M-ACG-122 D-Drive Relay Expansion
Module Manual
32-Aug-22
2. Contents
1. Safety Warnings ................................................................................................................................... 2
2. Contents ............................................................................................................................................... 3
3. General Information.............................................................................................................................. 4
4. Schematic Drawings............................................................................................................................. 4
4.1. Single Relay Module DDEB-1R.................................................................................................... 4
4.2. Six Relay Module DDEB-6R......................................................................................................... 4
5. Specifications ....................................................................................................................................... 5
6. Installation............................................................................................................................................. 6
6.1. Single Relay Module DDEB-1R.................................................................................................... 6
6.2. Six Relay Module DDEB-6R......................................................................................................... 6
7. Relay Output Configuration .................................................................................................................. 7

D-M-ACG-122 D-Drive Relay Expansion
Module Manual
42-Aug-22
3. General Information
Grifco offers Relay Expansion Module options for use with the D-Drive Inverter Controllers DDI-07, DDI-
12, and DDI-15.
These provide an additional 1 or 6 relay outputs, dependant on model.
The modules can be used on D-Drive Wall Controller Variable Speed / Inverter Controllers DDI-07, DDI-
12 and DDI-15.
CAUTION Use only 75 °C copper cable to connect to the expansion board.
4. Schematic Drawings
4.1. Single Relay Module DDEB-1R
4.2. Six Relay Module DDEB-6R

D-M-ACG-122 D-Drive Relay Expansion
Module Manual
52-Aug-22
5. Specifications
DDEB-1R DDEB-6R
Dimensions (LxWxH) 30 x 36 x 43 mm 112 x 8 x 30 mm
Connection 1 x MOLEX-Socket strip to M2A 1 x 5 Pin Ribbon Cable to X30a
Operating Temperature -20°C to +50°C -20°C to +50°C
Storage Temperature -20°C to +70°C -20°C to +70°C
Power Consumption 25mA (without relays and outputs)
Max. 2W
Weight 27g 150g
Relay Contact (general) min. 10 mA*
max. 230 VAC / 3 A
min. 10 mA*
max. 230 VAC / 3 A
Inputs N/A 24 VDC / typ.15 mA
max. 26 VDC / 20 mA
All inputs must be connected potential-
free or:
< 4 V: inactive for logical 0
>16 V: active for logical 1
min. duration of input control commands:
> 100 ms
Relay Output Normally open contact with common
COM port.
Max. 230 VAC / 3 A in total are allowed.
Relays OUT 5 – OUT 8:
Normally open contact with common
COM port.
Max. 230 VAC / 3 A in total are allowed.
Relays OUT 9 – OUT 10:
Changeover contact free of potential.
The same switching voltage must be
used for both relays!
Digital Output N/A OUT 11:
1 x 24 V
min. 10 mA*
max. 100 mA
normally open, +24 V switching
CAUTION Contacts which have been used once for power switching can no longer switch extra-low
voltage

D-M-ACG-122 D-Drive Relay Expansion
Module Manual
62-Aug-22
6. Installation
6.1. Single Relay Module DDEB-1R
Plug the White MOLEX connector on the relay module onto the M2A Header connector of the DDI-07,
DDI-12 or DDI-15.
6.2. Six Relay Module DDEB-6R
Parts provided in the kit are shown below.
1. Mount the 4 spacers (E) on the expansion board using the 4 screws (B) (shown below)
2. Connect one end of the cable (F) to the connection X30a on the relay module. Connect other end of
cable (F) to the connection X30a on the DDI-07, DDI-12 or DDI-15 controller circuit board.
3. Activate the expansion board via the controller by setting parameter P.800 to 8.

D-M-ACG-122 D-Drive Relay Expansion
Module Manual
72-Aug-22
7. Relay Output Configuration
To configure an output of the controller to the onboard and plug-in Relay Modules, navigate to the
appropriate P.70x setting (where ‘x’ is the number of the Output to be configured) and change the saved
setting to an option in the table below:
Setting
Description
0000
Output deactivated
0001
Continuously turned on
0101
Door is Open
The message depends on the logical status of the door
0103
Door is Open
The message depends on the logical status of the door
0201
Door is Closed
The message depends on the logical status of the door
0203
Door is Closed
The message depends on the logical status of the door
0401
There is no error
0501
Courtyard light function, switched ON during opening and closing with 10 s switch off delay after
closing.
0601
Passing on detector channel 1
0602
Passing on detector channel 2
0605
Synchronous control OPEN, signal duration 0.5 seconds.
The output is active during opening, in End position OPEN and during locking in end open
position.
0606
Synchronous control CLOSE, signal duration 0.5 seconds.
The output is active during Closing, in End position Close and during locking in end position close.
0607
Synchronous control STOP, signal duration 0.5 seconds.
The output is active when the door is not moving, no end position is approached and no locking in
any end position is active.
0612
Passing on leaving detector 1
0613
Passing on leaving detector 2
0630
Forwarding Brake
0634
Forwarding, of an low Battery from the WiCab mobile Unit
0659
F.363: forwarding disturbance of the internal safety edge.
0660
Forwarding: maximum number of trips of the safety edges has been exceeded.
0665
Forwarding detector channel 3
0666
Forwarding detector channel 4
0701
Flashing during opening and closing
0703
Switched on during Opening and Closing
0801
Active during opening and closing and during active pre-warning / clearance time.
1001
Locking second door
1002
Locking second door, 1 s switch off delay
1101
Magnet voltage in end position CLOSE
The N.C. contact of the relay has to be used
1102
Magnet voltage during Closing and in end position CLOSE

D-M-ACG-122 D-Drive Relay Expansion
Module Manual
82-Aug-22
Setting
Description
1201
Green traffic light on inside of door
1210
Green traffic light on outside of door
1220
Red traffic light on inside of door 1
1221
Flashing red traffic light on inside of door 1
1222
Red traffic light on inside of door 2
1223
Flashing red traffic light on inside of door 2
1224
Red traffic light on inside of door
1232
Red traffic light on inside
1233
Red traffic light on inside, inverted
1250
Red traffic light on outside of door 1, flashing during clearance time
1251
Flashing red traffic light on outside of door 1
1252
Red traffic light on outside of door 2
1253
Flashing red traffic light on outside of door 2
1255
Red traffic light on outside of door
1263
Red traffic light on outside
1264
Red traffic light on outside, inverted
1295
Green traffic light, flashing during pre-warning / clearance time, ON in end position OPEN
1298
Direction dependent red traffic light. On for opening and closing movement. Off when CLOSED
and when OPEN. Flashes during evacuation time
12AD
Direction-independent traffic light, flashing during clearing time, switched on during OPEN and
CLOSE movement, flashing during stop
1601
Airlock OPEN
1701
Testing in end position close
1801
Counting +
The function is only possible with detectors 1 and 2. At first you have to activate the + loop and
then the - loop.
1901
Counting –
The function is only possible with detectors 1 and 2. At first you have to activate the - loop and
then the + loop.
2001
Warning light 1, always ON if door is not closed.
2101
Warning light 2, switched ON during closing
2201
Active green traffic light, ON in end position OPEN until a close command is given or detector 2
gets active.
2301
Active green traffic light, ON in end position OPEN until a close command is given or detector 1
gets active.
2501
Testing in end position OPEN
2601
Emergency opening test
3201
Output function brake
3202
Output function brake (N.C., output turned)

D-M-ACG-122 D-Drive Relay Expansion
Module Manual
92-Aug-22
Chamberlain Australia Pty Ltd
Unit 1, 75 Epping Road
North Ryde NSW 2113
Ph: 1800 GRIFCO
Chamberlain New Zealand Ltd
17B Arrenway Drive
Rosedale 0623 Auckland
Ph: 0800 653 667
www.grifco.co.nz

D-M-ACG-122 D-Drive Relay Expansion
Module Manual
10 2-Aug-22
www.grifco.com.au
This manual suits for next models
1
Table of contents
Other Grifco Controllers manuals
Popular Controllers manuals by other brands

Rosslare
Rosslare AC-Q41HB Installation and programming manual

Emerson
Emerson Asco Sentronic LP 617 Series installation manual

Embedded Systems
Embedded Systems PT1000 Quick start up guide

Regler
Regler WRX Instructions for installation and use

Pilz
Pilz PNOZ m EF SafetyNET operating manual

ITALFARAD
ITALFARAD IFC5 operating instructions

NOVAK
NOVAK MICRO GT manual

PIETRO FIORENTINI
PIETRO FIORENTINI Dival 700 Use and maintenance

Siemens
Siemens SIMATIC NET S7-1200 operating instructions

Sun Microsystems
Sun Microsystems Fire 6800 Reference manual

Carel
Carel Datalogger user manual

Siemens
Siemens RAJA+ 3TE7131-1HC14-1A Installation, Maintenance & Troubleshooting Guide