Electrical Work
Before beginning installation procedures, these installation and operating instructions should
be studied carefully. All electrical work should be carried out by a qualified electrician in
accordance with the latest edition of the National Electrical Code(NEC), local codes and
regulations.
Adherence To Environmental
Regulations
When handling and operating the Redi-Flo Variable Performance Pump system, all
environmental regulations concerning the handling of hazardous materials must be observed.
When the pump is taken out of operation, great care should be taken to ensure that the pump
containsnohazardousmaterialsthatmightcauseinjurytohumanhealthortotheenvironment.
Returning a Pump for Service
Only pumps that are certified as uncontaminated will be accepted by GRUNDFOS for
servicing. GRUNDFOS must receive this certification prior to receiving the pump. If not,
GRUNDFOS will refuse to accept delivery of the pump. In these cases, all costs incurred in
returning the product to the customer will be paid by the customer. Contact your distributor
for details on returning Redi-Flo products for servicing.
ElectricalHazards
The Redi-Flo Variable Performance Pump system is not approved for Class 1, Division 1,
GroupDlocationsas specifiedbythe National ElectricalCode(NEC). Consultlocalauthorities
and regulations if you have any doubt about its suitability for a specific application.
WARNING
Hazard of Electric Shock: Do not expose the Redi-Flo Variable Frequency Drive
(VFD) to moisture. If unavoidable exposure to moisture occurs, disconnect the
electrical supply power immediately and have the unit inspected by an authorized
service center to insure all safety features of the unit are in tact. To reduce the
risk of electrical shock during operation of this Redi-Flo product, extreme care
shouldbetakentoensureadequategrounding. AllRedi-Floproductsareprovided
withgrounding provisionswhich complywith NECguidelines. Always verifypower
source is properly grounded and there is a solid ground connection between the
powersource and theRedi-Flo VFD before energizing. If the means of connection
tothe supply power source is other than grounded metal conduit, groundthe Redi-
Flo VFD back to the service by connecting a copper conductor, at least the size
ofthecircuitsupplying the Redi-FloVFD,to the groundingscrew/terminalprovided
within the wiring compartment of the Redi-Flo VFD.
Page 1
SAFETY WARNING
ELECTRIC
Redi-Flo Variable Frequency Drive
(Type: SI/MP1-115/230V)
TECHNICAL SPECIFICATIONS
DIMENSIONS AND WEIGHT
PROTECTIVE CASE CONSTRUCTION
STORAGE CONDITIONS
OPERATING CONDITIONS VFD ONLY
MINIMUM GENERATOR SIZE
Page 2
Input 115V +/- 10% / 1 PH / 48-62 Hz / 23A
230V +/- 10% / 1 PH / 48-62 Hz / 23A
Output with 115V Input 1.5 kw / 400 Hz / 220V / 3 PH / 5.5A (RF2)
1.5 kw / 80 Hz / 230V / 3 PH / 5.5A (RF4)
Output with 230V Input 1.5 kw / 400 Hz / 220V / 3 PH / 5.5A (RF2)
2.0 kw / 100 Hz / 230V / 3 PH / 6.7A (RF4)
Overload Rating 5.5A for 1 minute (RF2)
7.5A for 1 minute (RF4)
Acceleration Time (factory preset) 0 to 400 Hz: 5 seconds (RF2)
0 to 100 Hz: 5 seconds (RF4)
Deacceleration Time (factory preset) 400 to 0 Hz: 5 seconds (RF2)
100 to 0 Hz: 5 seconds (RF4)
Recommended Input Protection (115V) Fuse, 1 each, 250V, 25A, UL Class RK1
or circuit breaker, 25A/300V/1P
Recommended Input Protection (230V) Fuse, 2 each, 250V, 25A, UL Class RK1
or circuit breaker, 25A/300V/2P
Power Cord SJTW, 14 AWG, 10', NEMA PH-185 Plug
Output Ground Fault Protection Built-in (1000 mA)
Minimum Frequency (factory preset) 115 or 230V 25 Hz
Maximum Frequency (factory preset) 115 or 230V 400 Hz (RF2)
115V 80 Hz* (RF4)
*Auto Frequency Limiting
230V 100 Hz (RF4)
Dimensions Protective case is 9"x14"x18 1
¤2"
VFD Only - 6" x 7 1
¤2" x 10 1
¤2 "
Net Weight (VFD, Cord & Case) 20 lbs. (10 1
¤2lbs. - VFD only)
Ambient Temperature 14°F to 120°F (-10°C to 50°C)
Elevation Up to 3,300 ft. without derating
Ambient Temperature -4°F to 140°F (-20°C to 60°C)
Relative Humidity 95%, Non-condensing
Case High density polyethylene
Trim Aluminum
Lock Military twist type, steel with zinc plating
Redi-Flo2®
For Generators with Voltage Regulation 2500 Watts at 115/230 VAC, single phase
For Generators without Voltage Regulation 5000 Watts at 115/230 VAC, single phase
Recommended For Optimal Performance 4000 Watts at 115/230 VAC, single phase
with voltage regulation.
Redi-Flo4™
For Generators with Voltage Regulation 3400 Watts at 115/230 VAC, single phase
For Generators without Voltage Regulation 6700 Watts at 115/230 VAC, single phase
Recommended For Optimal Performance 5400 Watts at 115/230 VAC, single phase
with voltage regulation.
Note: RF2 = Redi-Flo2® RF4 = Redi-Flo4™