Page
1. LIMITED WARRANTY
Products manufactured by GRUNDFOS PUMPS CORPORATION
(Grundfos) are warranted to the original user only to be free of
defects in material and workmanship for a period of 24 months
from date of installation, but not more than 30 months from date
of manufacture. Grundfos' liability under this warranty shall be
limited to repairing or replacing at Grundfos' option, without
charge, F.O.B. Grundfos' factory or authorized service station,
any product of Grundfos' manufacture. Grundfos will not be liable
for any costs of removal, installation, transportation, or any other
charges which may arise in connection with a warranty claim.
Products which are sold but not manufactured by Grundfos are
subject to the warranty provided by the manufacturer of said
products and not by Grundfos' warranty. Grundfos will not be
liable for damage or wear to products caused by abnormal
operating conditions, accident, abuse, misuse, unauthorized
alteration or repair, or if the product was not installed in
accordance with Grundfos' printed installation and operating
instructions.
To obtain service under this warranty, the defective product must
be returned to the distributor or dealer of Grundfos' products from
which it was purchased together with proof of purchase and
installation date, failure date, and supporting installation data.
Unless otherwise provided, the distributor or dealer will contact
Grundfos or an authorized service station for instructions.
Any defective product to be returned to Grundfos or a service
station must be sent freight prepaid; documentation supporting
the warranty claim and/or a Return Material Authorization must
be included if so instructed.
GRUNDFOS WILL NOT BE LIABLE FOR ANY INCIDENTAL OR
CONSEQUENTIAL DAMAGES, LOSSES, OR EXPENSES
ARISING FROM INSTALLATION, USE, OR ANY OTHER
CAUSES. THERE ARE NO EXPRESS OR IMPLIED
WARRANTIES, INCLUDING MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE, WHICH EXTEND BEYOND
THOSE WARRANTIES DESCRIBED OR REFERRED TO
ABOVE.
Some jurisdictions do not allow the exclusion or limitation of
incidental or consequential damages and some jurisdictions do
not allow limit actions on how long implied warranties may last.
Therefore, the above limitations or exclusions may not apply to
you. This warranty gives you specific legal rights and you may
also have other rights which vary from jurisdiction to jurisdiction.
2. Symbols used in this document
3. General description
This booklet includes instructions for installation, operation and
maintenance of Grundfos SL1 and SLV submersible sewage and
wastewater pumps with motors of 1.1 to 11 kW. Grundfos SL1
and SLV sewage pumps are designed for pumping domestic and
industrial sewage and wastewater.
1. LIMITED WARRANTY 2
2. Symbols used in this document 2
3. General description 2
3.1 Product drawing 3
3.2 Control and monitoring 3
3.3 Applications 3
3.4 Operating conditions 3
4. Delivery and handling 4
4.1 Transportation 4
4.2 Storage 4
5. Identification 4
5.1 Nameplate 4
5.2 Type key 5
6. Approvals 6
6.1 Explanation to FM approval 6
7. Safety 6
7.1 Potentially explosive environments 7
8. Installation 7
8.1 Submerged installation on auto-coupling 8
8.2 Free-standing submerged installation on ring stand 8
8.3 Torques for suction and discharge flanges 9
9. Electrical connection 9
9.1 Wiring diagrams 11
9.2 Pump controllers 14
9.3 Thermal switch, Pt1000 and thermistor 14
9.4 WIO sensor (water-in-oil sensor) 14
9.5 Moisture switch 14
9.6 IO 113 15
9.7 Frequency converter operation 15
10. Start-up 16
10.1 General start-up procedure 16
10.2 Operating modes 16
10.3 Direction of rotation 17
11. Maintenance and service 17
11.1 Inspection 17
11.2 Dismantling the pump 18
11.3 Assembling the pump 19
11.4 Oil quantities 20
11.5 Service kits 20
11.6 Contaminated pumps 20
12. Fault finding 21
13. Technical data 23
14. Disposal 24
Warning
Prior to installation, read these installation and
operating instructions. Installation and operation
must comply with local regulations and accepted
codes of good practice.
Warning
The use of this product requires experience with and
knowledge of the product.
Persons with reduced physical, sensory or mental
capabilities must not use this product, unless they
are under supervision or have been instructed in the
use of the product by a person responsible for their
safety.
Children must not use or play with this product.
Warning
If these safety instructions are not observed, it may
result in personal injury.
Warning
If these instructions are not observed, it may lead to
electric shock with consequent risk of serious
personal injury or death.
Warning
These instructions must be observed for explosion-
proof pumps. It is advisable also to follow these
instructions for standard pumps.
If these safety instructions are not observed, it may
result in malfunction or damage to the equipment.
Notes or instructions that make the job easier and
ensure safe operation.
FM