If you are able to hard plumb the upstream side of the valve into a freshwater supply line, then this is the
preferred method. However, you should make sure that a provision is made to drain this line for winterizing your
equipment. If hard plumbing is not an option, then you can connect the upstream side of the valve to a garden
hose and spigot. Thread into the upstream side of the valve a 1” male NPT to ¾” female NPT adapter. Into this,
thread in a ¾” male NPT to ¾” MHT (male hose thread) adapter. Now connect a suitable length garden hose
from the valve to a spigot. If the spigot serves another garden hose, install a ‘Y’ and connect both the LevelSmart
hose and the existing garden hose. Make sure that the homeowner is informed that the valve on the ‘Y’ to the
LevelSmart is never turned o. If possible, ax a tag to inform people not to turn it o.
Important Note: Many local jurisdictions require a non-return / backow preventer when installing ll lines
or irrigation systems to city water supplies. It is the installer’s responsibility to check into this and to install an
appropriate device if necessary.
b) Install and connect the Valve Controller
The valve controller should be mounted on the wall next to the equipment pad and no more than 6 feet from the
valve installed in section a) above. Stainless steel screws and plastic wall plugs are provided for your convenience.
The 6-foot-long black wire (with red and black wire tails), coming from the bottom right-hand side of the valve
controller should be connected to the two red wires connected to the solenoid of the valve. Note that this is 24
VAC power and therefore not polarity sensitive; the black and red wires coming from the valve controller can be
connected to either of the red wires coming from the valve. Wire nuts are provided.
c) Connect the Antenna
Connect the Antenna plug to the socket on the lower le of the valve controller. Do not mount the Antenna at
this time, but place it loosely in a location where it can see the pool and where it can be adhered if a successful
pairing of the Level Sensor to the Valve Controller is achieved. Keep the Antenna at least 12 inches away from any
metal as this will interfere with the wireless communication between the Level Sensor and Valve Controller.