levelsmart™
Wireless Autofill
levelsmart™
Wireless Autofill
Follow us on
Plumb the valve into the designated water fill line, or “T”
it into the pool return plumbing after the filter and pump
equipment from a nearby water source. You can use a water
spigot, or “T” from a nearby irrigation line or similar. Add a
pressure regulator if desired.
Fill the pool to the desired
water level.
Make sure the valve solenoid
is in the “OFF” position (see right).
For best results, mount the Valve Controller in a protected
area out of direct sunlight and rain exposure. This component
is weather-proof rated, but is always better tucked away from
the elements if possible.
Mount the valve controller using the mounting screws
provided in the accessory pack.
Use the wire nuts provided to connect the Valve Controller
wires to the valve wires.
Connect the Valve Controller to the power transformer with
the two pin plug, then plug into power source.
All 3 LED lights will repeatedly flash in sequence from the
bottom to the top. This indicates that the unit is in pairing
mode. Move on to the next step while this is taking place.
Connect all antennas and tighten them.
Place antenna tip in desired mounting position o the ground
and 8-12 inches away from any metal.
Make sure Valve Controller is flashing in a sequence
indicating it is in pairing mode.
Take sensor to pool and remove magnet above the mounting
location. Leave on coping and watch the pairing process
take place at Valve Controller. The yellow ‘ACTION’ light will
flash for about 2.5 minutes.
Once Pairing is successful, a solid green LED will be seen on
the sensor.
If pairing is not successful, place the Valve Controller into
pairing mode by unplugging and plugging it back in. Then,
place the magnet on the sensor for at least 16 second and
remove. Once removed, repeat step 4.
Clean/scrub the area where the Water Level Sensor is to be
mounted.
Mount the water level sensor where the desired water is
about 0.5 - 1.5-inches up on the sensor.
Knead the epoxy thoroughly and spread on the dry back
suface of the sensor. Firmly press the sensor against the
mounting surface for at least 90 seconds, being sure that the
sensor is sitting 0.5 - 1.5-inches into the desired water level.
INSTALL THE VALVE
STEP 1
INSTALL & CONNECT VALVE CONTROLLER
STEP 2
CONNECT ANTENNAS TO VALVE CONTROLLER
STEP 3
PAIR SENSOR & VALVE CONTROLLER
STEP 4
ADHERE SENSOR AND MOUNT ANTENNA
STEP 5
Valve Controller Valve Level Sensor
R
O
T
A
T
E
QUICK START GUIDE
FOR LEVELSMART INSTALLATION
888.635.0296
levelsmart™
Wireless Autofill sales@h2flow.net www.h2flow.net
After the Water Level Sensor has adhered, use the magnet to
calibrate the water level. To do so, place the magnet in the bottom-
right corner of the Level Sensor, and hold it there for two-seconds
before removing it. A green light will appear on the sensor and
flash three times. This indicates the calibration has begun. A green
SENSOR light will also flash on the Valve Controller for about one-
minute, as the water level is set.
This step will conclude with a solid green SENSOR light. The
LevelSmart may start to fill for 7-minutes after installation. If
additional water isn’t required, shut o the water supply or
turndown the flow control knob for this 7-minute period. In some
cases, the LevelSmart does not fill immediately after pairing. As
long as the green SENSOR LED is visible, the unit has paired
successfully.
If LevelSmart is being installed to a smaller body of water, such
as a spa or small swimming pool, make sure to reduce the flow
control knob (the middle knob) so that the amount of water is
reduced on each fill. To do so, it’s recommended that the flow
control knob is tightened down half-way.
SET AND CALIBRATE YOUR WATER LEVEL
STEP 6
ADJUST FLOW CONTROL
IMPORTANT FOR SPA APPLICATIONS
STEP 7
DESIRED WATER LEVEL
SHOULD BE WITHIN HERE
Valve is in the OFF position
Only LED on Valve Controller is Green
SENSOR LED
Valve turned on for 7-minutes after water level
was calibrated
Antenna tip is not mounted on metal (fences,
rails, posts, and gutters)
Water level was calibrated between 0.5 - 1.5-
inch on the sensor
Keep magnet in a safe spot near the Valve
Controller for future engagement with
LevelSmart
Understand how LevelSmart works: After
installing and pairing, the LevelSmart sensor
will wake up every 30-minutes, take the
current water level measurement, and
communicate that information to the Valve
Controller. If water is needed, the controller
will open up the valve and fill for 7-minutes.
LevelSmart will continue to check the water
level every 30-minutes.
COMPLETED INSTALLATION CHECKLIST:
SCAN THE QR CODE TO VIEW VIDEOS OF ANY OF
THE INSTALLATION STEPS IN THIS DOCUMENT
LS QSG Rev.1.0

Other manuals for levelsmart

1

Popular Lighting Equipment manuals by other brands

Theatrelight Nova 24 Operation manual

Theatrelight

Theatrelight Nova 24 Operation manual

Ibiza LED-UVBAR user manual

Ibiza

Ibiza LED-UVBAR user manual

Velleman HQ-Power VDP7510S2 user manual

Velleman

Velleman HQ-Power VDP7510S2 user manual

Goobay 60344 user manual

Goobay

Goobay 60344 user manual

Flash professional P7200004 user manual

Flash professional

Flash professional P7200004 user manual

Elation Indoor Furnishings User instructions

Elation

Elation Indoor Furnishings User instructions

Candela ELE installation manual

Candela

Candela ELE installation manual

Conrad Disk operating instructions

Conrad

Conrad Disk operating instructions

Conrad 2388775 operating instructions

Conrad

Conrad 2388775 operating instructions

Philips SL BAR 660 Installation & user manual

Philips

Philips SL BAR 660 Installation & user manual

Life 39.9PF13150N quick start guide

Life

Life 39.9PF13150N quick start guide

LIVARNO home 1047-G manual

LIVARNO home

LIVARNO home 1047-G manual

EuroLite LED CLS-18 QCL user manual

EuroLite

EuroLite LED CLS-18 QCL user manual

PLG PICTOR 10 user manual

PLG

PLG PICTOR 10 user manual

Eaton 40011 CG-S Mounting and operating instructions

Eaton

Eaton 40011 CG-S Mounting and operating instructions

BAYLED ORCA 9 RGBWA installation guide

BAYLED

BAYLED ORCA 9 RGBWA installation guide

LIGMAN QUANTUM 3 QA-50021 installation manual

LIGMAN

LIGMAN QUANTUM 3 QA-50021 installation manual

tibelec 344510 instruction manual

tibelec

tibelec 344510 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.