levelsmart™
Wireless Autofill
levelsmart™
Wireless Autofill
Follow us on
Plumb the valve into the designated water fill line, or “T”
it into the pool return plumbing after the filter and pump
equipment from a nearby water source. You can use a water
spigot, or “T” from a nearby irrigation line or similar. Add a
pressure regulator if desired.
Fill the pool to the desired
water level.
Make sure the valve solenoid
is in the “OFF” position (see right).
For best results, mount the Valve Controller in a protected
area out of direct sunlight and rain exposure. This component
is weather-proof rated, but is always better tucked away from
the elements if possible.
Mount the valve controller using the mounting screws
provided in the accessory pack.
Use the wire nuts provided to connect the Valve Controller
wires to the valve wires.
Connect the Valve Controller to the power transformer with
the two pin plug, then plug into power source.
All 3 LED lights will repeatedly flash in sequence from the
bottom to the top. This indicates that the unit is in pairing
mode. Move on to the next step while this is taking place.
Connect all antennas and tighten them.
Place antenna tip in desired mounting position o the ground
and 8-12 inches away from any metal.
Make sure Valve Controller is flashing in a sequence
indicating it is in pairing mode.
Take sensor to pool and remove magnet above the mounting
location. Leave on coping and watch the pairing process
take place at Valve Controller. The yellow ‘ACTION’ light will
flash for about 2.5 minutes.
Once Pairing is successful, a solid green LED will be seen on
the sensor.
If pairing is not successful, place the Valve Controller into
pairing mode by unplugging and plugging it back in. Then,
place the magnet on the sensor for at least 16 second and
remove. Once removed, repeat step 4.
Clean/scrub the area where the Water Level Sensor is to be
mounted.
Mount the water level sensor where the desired water is
about 0.5 - 1.5-inches up on the sensor.
Knead the epoxy thoroughly and spread on the dry back
suface of the sensor. Firmly press the sensor against the
mounting surface for at least 90 seconds, being sure that the
sensor is sitting 0.5 - 1.5-inches into the desired water level.
INSTALL THE VALVE
STEP 1
INSTALL & CONNECT VALVE CONTROLLER
STEP 2
CONNECT ANTENNAS TO VALVE CONTROLLER
STEP 3
PAIR SENSOR & VALVE CONTROLLER
STEP 4
ADHERE SENSOR AND MOUNT ANTENNA
STEP 5
Valve Controller Valve Level Sensor
R
O
T
A
T
E
QUICK START GUIDE
FOR LEVELSMART INSTALLATION
888.635.0296
levelsmart™
Wireless Autofill sales@h2flow.net www.h2flow.net
After the Water Level Sensor has adhered, use the magnet to
calibrate the water level. To do so, place the magnet in the bottom-
right corner of the Level Sensor, and hold it there for two-seconds
before removing it. A green light will appear on the sensor and
flash three times. This indicates the calibration has begun. A green
SENSOR light will also flash on the Valve Controller for about one-
minute, as the water level is set.
This step will conclude with a solid green SENSOR light. The
LevelSmart may start to fill for 7-minutes after installation. If
additional water isn’t required, shut o the water supply or
turndown the flow control knob for this 7-minute period. In some
cases, the LevelSmart does not fill immediately after pairing. As
long as the green SENSOR LED is visible, the unit has paired
successfully.
If LevelSmart is being installed to a smaller body of water, such
as a spa or small swimming pool, make sure to reduce the flow
control knob (the middle knob) so that the amount of water is
reduced on each fill. To do so, it’s recommended that the flow
control knob is tightened down half-way.
SET AND CALIBRATE YOUR WATER LEVEL
STEP 6
ADJUST FLOW CONTROL
IMPORTANT FOR SPA APPLICATIONS
STEP 7
DESIRED WATER LEVEL
SHOULD BE WITHIN HERE
Valve is in the OFF position
Only LED on Valve Controller is Green
SENSOR LED
Valve turned on for 7-minutes after water level
was calibrated
Antenna tip is not mounted on metal (fences,
rails, posts, and gutters)
Water level was calibrated between 0.5 - 1.5-
inch on the sensor
Keep magnet in a safe spot near the Valve
Controller for future engagement with
LevelSmart
Understand how LevelSmart works: After
installing and pairing, the LevelSmart sensor
will wake up every 30-minutes, take the
current water level measurement, and
communicate that information to the Valve
Controller. If water is needed, the controller
will open up the valve and fill for 7-minutes.
LevelSmart will continue to check the water
level every 30-minutes.
COMPLETED INSTALLATION CHECKLIST:
SCAN THE QR CODE TO VIEW VIDEOS OF ANY OF
THE INSTALLATION STEPS IN THIS DOCUMENT
LS QSG Rev.1.0

Other manuals for levelsmart

1

Popular Lighting Equipment manuals by other brands

TEC-MAR 1810 Mounting instruction

TEC-MAR

TEC-MAR 1810 Mounting instruction

Lightolier 1004ICX Installation

Lightolier

Lightolier 1004ICX Installation

IOTA P-40 instruction manual

IOTA

IOTA P-40 instruction manual

Larson Electronics IND-LLP-UVC-KT.EV-R1-120V-0.75IN instruction manual

Larson Electronics

Larson Electronics IND-LLP-UVC-KT.EV-R1-120V-0.75IN instruction manual

Sealey LED042 instructions

Sealey

Sealey LED042 instructions

KOZii KE1500BRVBCCT instruction manual

KOZii

KOZii KE1500BRVBCCT instruction manual

TRANSNECT BC108 user manual

TRANSNECT

TRANSNECT BC108 user manual

NOUVOLED SOLAR PRO 200 CC user manual

NOUVOLED

NOUVOLED SOLAR PRO 200 CC user manual

MELINERA 279621 Operation and safety notes

MELINERA

MELINERA 279621 Operation and safety notes

Lightolier Lighting Systems Baselyte-BSL3 Specification sheet

Lightolier

Lightolier Lighting Systems Baselyte-BSL3 Specification sheet

Current Dual-Lite PLD10 Installation, operation and service instructions

Current

Current Dual-Lite PLD10 Installation, operation and service instructions

Beamz professional BPP225 instruction manual

Beamz professional

Beamz professional BPP225 instruction manual

Broncolor Siros user guide

Broncolor

Broncolor Siros user guide

Lightenjin FOCUS Mounting instructions

Lightenjin

Lightenjin FOCUS Mounting instructions

Integral LED ILSTRGBA163B Installation instruction

Integral LED

Integral LED ILSTRGBA163B Installation instruction

Briloner MAL 2267-150P Mounting instructions

Briloner

Briloner MAL 2267-150P Mounting instructions

Ayrton icecolor 1000 user manual

Ayrton

Ayrton icecolor 1000 user manual

Laserworld ES-400 RGY manual

Laserworld

Laserworld ES-400 RGY manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.