13
Electric wiring
6. Test run
CAUTION
THIS NIT WILL BE STARTED INSTANTLY WITHO T "ON" OPERATION
WHEN ELECTRIC POWER IS S PPLIED.BE S RE TO EXEC TE "OFF"
OPERATION BEFORE ELECTRIC POWER IS DISCONNECTED FOR
SERVICING.
This unit has a function of automatic restart system after recovering power stoppage.
Installation Procedure
Failure descrip ion
Room emp. sensor abnormal
Indoor coil emp. sensor abnormal
Ou door coil emp. sensor abnormal/
(compressor discharge emp. sensor)
Over-curren malfunc ion/ power supply abnormal
Communica ion malfunc ion be ween indoor and wired con roller
Communica ion malfunc ion be ween indoor and ou door abnormal
Ou door coil gas pipe emp. Sensor abnormal
Code on wired Flash imes of indoor
con roller receiver board
01 Power LED flashes 1 ime
02 Power LED flashes 2 imes
4A Power LED flashes 3 imes
49 Power LED flashes 4 imes
48 Power LED flashes 5 imes
53 Power LED flashes 6 imes
07 Power LED flashes 8 imes
06 Power LED flashes 9 imes
03 Power LED flashes 12 imes
Ou door emp. sensor abnormal
High / Low pressure abnormal
Tempera ure pro ec ion malfunc ion 0D Power LED flashes 13 imes
Drainage sys em malfunc ion 08 Power LED flashes 10 imes
0B Power LED flashes 11 imes
Alarm of ex erior annuncia or
7. Trouble display
(1) Before starting test run (for all Heat pu p odels)
Confirm whether the power source breaker (main switch) of the unit has been
turned on for over 12 hrs to energize the crankcase heater in advance of operation.
(2) Test run
Run the unit continuously for about 30 minutes, and check the following.
Suction pressure at check joint of service valve for gas pipe.
Discharge pressure at check joint on the compressor discharge pipe.
Temperature difference between return air and supply air for indoor unit.
The following consults are according to the EMC testing.
Through poor conditions of the electrical MAINS, shortly voltage drops can appear
when starting the EQ IPMENT. This can influence other equipment (eg. Blinking
of a lamp ). But if the Mains-Impedance Zmax value can meet the below chart, such
disturbances are not expected. (In case of need, you may contact your local supply
authority for further information ).
Model Zmax value
A 60NAIEAA <0.2708OHM
A 48NAIEAA
A 282AHEAA A 362AIEAA A 362ALEAA
<0.2984OHM
<0.0741OHM
A 242AGEAA <0.2721OHM
A 36NAIEAA <0.2830OHM
<0.2221OHM
A 42NALEAA