manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Haier
  6. •
  7. Remote Control
  8. •
  9. Haier YR-HD User manual

Haier YR-HD User manual

YR-HD REMOTE CONTROLLER OPERATION MANUAL
Remote controller
Parts and Functions
1
18
19
20
21
23
24
25
22
11
10
12
13
14
15
16
17
2
3
4
5
6
7
8
9
1. Mode display
Operation mode AUTO COOL DRY
Remote controller
Operation mode HEAT FAN
Remote controller
2. Signal sending display
3. SWING display
4. FAN SPEED display
LO MED HI AUTO
Display
circulated
5. LOCK display
6. TIMER OFF display
TIMER ON display
7. TEMP display
8. Additional functions display
Operation
mode QUITE SLEEP TURBO FRESH
Remote
controller
Operation
mode
ELECTRICAL
HEATING HEALTH
Remote
controller
9. QUIET button
10. HEAT button
11. COOL button
12. AUTO button
13. FAN SPEED button
14. TIMER button
15. HEALTH button
16. LOCK button
Used to lock buttons and LCD display.
17. LIGHT button (This model has not
this function.)
Control the lightening and extinguishing
of the indoor LED display board.
18. POWER ON/OFF button
19. DRY button
20. TEMP button
21. SWING button
22. Timer adjust button
23. EXTRA FUNCTION button
Function: Fan only function, health
airow upwards and downwards
sending function, sleep function, Fresh
function, Fahrenheit Celsius conversion,
Power setting function, left and right
swing function, 10°C heating function,
B code, Electrical Heating function.
24.CANCEL/CONFIRM button
Function: Setting and cancel to the
timer and other additional functions.
25. RESET button
When the remote controller appears
abnormal, use a sharp pointed article
to press this button to reset the remote.
Loading of the battery
1. Remove the battery cover;
2. Load the batteries as illustrated. 2
R-03 batteries, resetting key (cylinder);
3. Be sure that the loading is in line with
the " + "/"-";
4. Load the battery,then put on the cover
again.
Note:
• The distance between the signal transmission head and the receiver
hole should be within 7m without any obstacle as well.
• When electronic-started type uorescent lamp or change-over type
uorescent lamp or wireless telephone is installed in the room, the
receiver is apt to be disturbed in receiving the signals, so the distance
to the indoor unit should be shorter.
• Full display or unclear display during operation indicates the batteries
have been used up. Please change batteries.
• If the remote controller can't run normally during operation, please
remove the batteries and reload several minutes later.
Hint: Remove the batteries in case won't be in use for a long period. If
there is any display after taking-out, just press reset key.
Operation
Base Operation
1
3
2
4
1. Unit start
Press ON/OFF on the remote controller, unit starts.
2. Select operation mode
COOL button:Cooling mode; HEAT button: Heating mode; DRY button: Dehumidify mode
3. Select temp.setting
Press / button
Every time the button is pressed, temp.setting increase 1°C, if kept depressed,
it will increase rapidly.
Every time the button is pressed, temp.setting decrease 1°C, if kept depressed,
it will decrease rapidly.
Select a desired temperature.
4. Fan speed selection
Press FAN button. For each press, fan speed changes as follows:
Remote controller:
LO MED HI AUTO
Display
circulated
Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air
conditioner automatically adjusts the fan speed according to room temperature.
NO. 0150520000
Operation
Mode
Remote
Controller Note
AUTO
Under the mode of auto operation, air conditioner
will automatically select Cool /Heat / Fan operation
according to room temperature. When FAN is set to
AUTO the air conditioner automatically adjusts the
fan speed according to room temperature.
COOL
DRY
In DRY mode , when room temperature becomes
lower than temp.setting+2°C, unit will run
intermittently at LOW speed regardless of FAN
setting (only valid for part of models).
HEAT
In HEAT mode, warm air will blow out after a short
period of the time due to cold-draft prevention
function. When FAN is set to AUTO, the air
conditioner automatically adjusts the fan speed
according to room temperature.
FAN
In FAN operation mode , the unit will not operate in
COOL or HEAT mode but only in FAN mode, AUTO
is not available in FAN mode. And temp. setting
is disabled. In FAN mode, sleep operation is not
available.
Sleep Operation
Press button to enter additional options, when cycle display
to , will ash. And then press enter to sleep function.
1. In COOL, DRY mode
1 hours after SLEEP mode starts, temp.will become 1°C higher
than temp.setting.After another 1 hours, temp.rises by 1°C futher.
The unit will run for further 6 hours then stops Temp. is higher than
temp.setting so that room temperature won’t be too low for your
sleep.
2.In HEAT mode
1 hours after SLEEP mode starts,temp will become 2°C lower than
temp. setting. After another 1 hours, temp decrease by 2°C futher.
After more another 3 hours, temp. rises by 1°C futher.The unit will
run for further 3 hours then stops.Temp.is lower than temp. setting
so that room temperature won’t be too high for your sleep.
Operation Mode
3.In AUTO mode
The unit operaters in corresponding sleep mode adapted to the
automatically selected operation mode.
4. In FAN mode
It has no SLEEP function.
Note: When TIMER function is set, the sleeping function can't be set up.
After the sleeping function is set up, if user resets TIMER function, the
sleeping function will be cancelled; the machine will be in the state of
timing on/ timing off.
POWER/QUIET Operation
1. POWER Operation
When you need rapid heating or cooling, you can use this function.
Press button to enter additional options, when cycle display
to , will ash, and then press , enter to power
function. When cancel the function, please enter additional options
again and to cancel power function.
2. QUIET Operation
You can use this function when silence is needed for rest or
reading. Press QUIET button, the remote controller will show
, and then achieve to the quiet function. Press again this QUIET
button , the quiet function will be cancelled.
Note: During POWER operation, in rapid HEAT or COOL mode, the room
will show inhomogeneous temperature distribution. Long period QUIET
operation will cause effect of not too cool or not too warm.
SLEEP operation starts
In COOL, DRY mode
SLEEP operation stops
Approx. 6hrs
Temp. setting
Rises 1°C
Rises 1°C
1 hr
1 hr
Unit stop
SLEEP operation starts
In HEAT mode
SLEEP operation stops
Temp. setting
Rises 1°C
Decreases 2°C
Decreases 2°C
1 hr
1 hr
3 hrs
3 hrs
Unit stop
Timer On/Off On-Off Operation
1.After unit starts, select your desired operation mode.
2.Press TIMER button to change TIMER mode. Every time the
button is pressed, display changes as follows: Remote controller:
Then select your desired TIMER mode (TIMER ON or TIMER OFF
or TIMER ON-OFF). " "or " "will ash.
3.Press / button to set time.
Press the button for each time, setting time in the rst
12 hours increased by 0.5 hour every time, after 12
hours,increased by 1 hour every time.
Press the button for each time, setting time in the rst
12 hours decreased by 0.5 hour every time, after 12
hours,decreased by 1 hour every time.
It can be adjusted within 24 hours.
4.Conrm timer setting
After adjust the time, press button and conrm the time ON
or OFF button will not ash any more.
5.Cancel timer setting
Press the timer button by times until the time display eliminated.
Press button to cancel timer setting.
Hints: After replacing batteries or a power failure happens, time setting
should be reset. According to the Time setting sequence of TIMER ON or
TIMER OFF, either Start-Stop or Stop-Start can be achieved.
Healthy airow Operation
1.Press to starting
Setting the comfort work conditions.
2.The setting of healthy airow function
Press button to enter additional options,Press this button
continuously, the louvers location will cycle between in the following
three locations, to choose the swing location what you needed,and
then press button to conrm.
Healthy
airow
upwarder
Healthy
airow
downwarder
Left and
Right
swing
3.The cancel of the healthy airow function
Press button to enter additional options,Press this button
continuously, the louvers location will cycle between in the following
three locations again,and then press button to cancel.
Note:
1.After setting the healthy airow function, the position grill is xed.
2.In heating, it is better to select the mode.
3.In cooling, it is better to select the mode.
4.In cooling and dry, using the air conditioner for a long time under the
high air humidity, condensate water may occur at the grille .
Air Flow Direction Adjustment
1.Status display of air ow
COOL/DRY:
HEAT:
2. Left and right air ow adjustment
Initial state
Initial state

Other Haier Remote Control manuals

Haier YR-H71 User manual

Haier

Haier YR-H71 User manual

Haier YR-E17 User manual

Haier

Haier YR-E17 User manual

Haier HSU-09LA10 - annexe 1 User manual

Haier

Haier HSU-09LA10 - annexe 1 User manual

Haier HBS01 User manual

Haier

Haier HBS01 User manual

Haier YR-HQ User manual

Haier

Haier YR-HQ User manual

Haier YR-HBS01 User manual

Haier

Haier YR-HBS01 User manual

Haier HTR-D51 User manual

Haier

Haier HTR-D51 User manual

Haier YR-E06 User manual

Haier

Haier YR-E06 User manual

Haier YR-F02 User manual

Haier

Haier YR-F02 User manual

Popular Remote Control manuals by other brands

Muller paladin 670 010 rf manual

Muller

Muller paladin 670 010 rf manual

Spektrum DX8 instruction manual

Spektrum

Spektrum DX8 instruction manual

Calex 429204 Getting started

Calex

Calex 429204 Getting started

MOFILY YOYO user manual

MOFILY

MOFILY YOYO user manual

Supersonic Gate and Door Automation GIT-1 Programming instructions

Supersonic Gate and Door Automation

Supersonic Gate and Door Automation GIT-1 Programming instructions

X10 CR13A Installation and operating instructions

X10

X10 CR13A Installation and operating instructions

One Forall URC-6820 user manual

One Forall

One Forall URC-6820 user manual

Speed Link SL-4112 user guide

Speed Link

Speed Link SL-4112 user guide

Fly Sky Noble NB4 user manual

Fly Sky

Fly Sky Noble NB4 user manual

Tripp Lite Keyspan URM-15T owner's manual

Tripp Lite

Tripp Lite Keyspan URM-15T owner's manual

Silvercrest SFS 18 A1 User manual and service information

Silvercrest

Silvercrest SFS 18 A1 User manual and service information

Paradox Magellan MG-REM1 instructions

Paradox

Paradox Magellan MG-REM1 instructions

Digi-Code 5040 Installation instructions manual

Digi-Code

Digi-Code 5040 Installation instructions manual

One Forall URC1281 manual

One Forall

One Forall URC1281 manual

Jline Quattro Lite instruction manual

Jline

Jline Quattro Lite instruction manual

Alpic Air YV1L1 user manual

Alpic Air

Alpic Air YV1L1 user manual

One Forall URC7125 quick start guide

One Forall

One Forall URC7125 quick start guide

Fantini Cosmi CT3MA instruction manual

Fantini Cosmi

Fantini Cosmi CT3MA instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.