Haier YR-E16b User manual

WIRED CONTROLLER Page 1
ENGLISH
YR-E16b Wired Controller
User Manual
TABLE OF CONTENTS
Ductless Split Air Conditioner
Wired Control Panel Functions .................. 2
Features and Interface....................................2
Installation................................................ 4
Operation ................................................. 5
Settings & Functions.......................................5
• ThissystemshouldbeinstalledbyaqualiedHVAC
professional.Incorrectinstallationmaycausere,water
damage, personalinjuryordeath.
• Whenabnormalitiessuchasaburntsmellaredetected,
immediatelypowerothemainswitchandcontacta
licensed contractor.
• Do not obstruct or cover ventilation grill on the air con-
ditioner.Donotputngers/objectsintoinlet,outletor
swinglouver
• Donotallowchildrentoplayonorneartheoutdoor
system equipment
WARNING
!
Thursday
Set temp.
Mode Menu Swing
Indoor temp.
Qty. online
Standby
Defrost Master
Outdoor temp. 36 °F
Outdoor humidity 32%RH
70 °F
32%RH
Indoor humidity
76°F
10:30AM
01.01.2015

Page 2 WIRED CONTROLLER
ENGLISH
WIRED CONTROL PANEL FUNCTIONS
Wired Controller YR-E16b
Features and Interface
1
Left
Thursday
Set temp.
Mode Menu Swing
Indoor temp.
Qty. online
Standby
Defrost Master
Outdoor temp. 36 °F
Outdoor humidity 32%RH
70 °F
32%RH
Indoor humidity
76°F
10:30AM
01.01.2015
Modekeyinthemaininterface,return
key in other interface.
2
Thursday
Set temp.
Mode Menu Swing
Indoor temp.
Qty. online
Standby
Defrost Master
Outdoor temp. 36 °F
Outdoor humidity 32%RH
70 °F
32%RH
Indoor humidity
76°F
10:30AM
01.01.2015
Autokey,Pressittoenableautomode
immediately.
34
Thursday
Set temp.
Mode Menu Swing
Indoor temp.
Qty. online
Standby
Defrost Master
Outdoor temp. 36 °F
Outdoor humidity 32%RH
70 °F
32%RH
Indoor humidity
76°F
10:30AM
01.01.2015
Thursday
Set temp.
Mode Menu Swing
Indoor temp.
Qty. online
Standby
Defrost Master
Outdoor temp. 36 °F
Outdoor humidity 32%RH
70 °F
32%RH
Indoor humidity
76°F
10:30AM
01.01.2015
Left/Rightkey,fanspeedadjustment
key,swingangleadjustmentkeyinthe
maininterface,directionadjustment
key in other interface.
56
Thursday
Set temp.
Mode Menu Swing
Indoor temp.
Qty. online
Standby
Defrost Master
Outdoor temp. 36 °F
Outdoor humidity 32%RH
70 °F
32%RH
Indoor humidity
76°F
10:30AM
01.01.2015
Thursday
Set temp.
Mode Menu Swing
Indoor temp.
Qty. online
Standby
Defrost Master
Outdoor temp. 36 °F
Outdoor humidity 32%RH
70 °F
32%RH
Indoor humidity
76°F
10:30AM
01.01.2015
Up/Downkey,temp.adjustmentkey
inthemaininterface,shiftdirection
andvalueadjustmentkeyinother
interface.
7
Thursday
Set temp.
Mode Menu Swing
Indoor temp.
Qty. online
Standby
Defrost Master
Outdoor temp. 36 °F
Outdoor humidity 32%RH
70 °F
32%RH
Indoor humidity
76°F
10:30AM
01.01.2015
Menukeyinthemaininterface,enter
key in other interface.
8
Right
Thursday
Set temp.
Mode Menu Swing
Indoor temp.
Qty. online
Standby
Defrost Master
Outdoor temp. 36 °F
Outdoor humidity 32%RH
70 °F
32%RH
Indoor humidity
76°F
10:30AM
01.01.2015
Swingkeyinthemaininterface,back
to the main interface through the key
inotherinterface.When theswing
functionisinvalid,pressthekeyto
adjustfanspeed.
9
Thursday
Set temp.
Mode Menu Swing
Indoor temp.
Qty. online
Standby
Defrost Master
Outdoor temp. 36 °F
Outdoor humidity 32%RH
70 °F
32%RH
Indoor humidity
76°F
10:30AM
01.01.2015
On/Okey
Quiet function.
Turbo function.
Childlockfunction.PreetheLeftand
Right keys at the same time in the
main interface for 5s to either set or
cancel the function.
Forced defrost function. (Function is
not available for mini-split and multi-
split.)
Ventilationfunction.(Functionisnot
available for mini-split and multi-split.)
Healthfunction.(Functionisnot
available for mini-split and multi-split.)
Quick start function. (Function is not
available for mini-split and multi-split.)
Nightquietfunction,thisfunction
operationsonlyatnightwhenset.
(Function is not available for mini-split
and multi-split.)
Electrical heating. (Function is not
available for mini-split and multi-split.)
Autoswing.
Autoswingup.
Autoswingdown.
Sleep function.
Errorcodefunction,thisiconwill
displayinthemaininterfacewhen
thewiredcontrollerortheindoorunit
linked to the controller has an error.
Weekly programming.
1
2
3
5
7
4
6
8
9

WIRED CONTROLLER Page 3
ENGLISH
Date,week,clockdisplayarea,
the format the of date can
be changed through the time
function.
Set Temperature range
60°F-86°F
Indoor room temperature.
Indoor humidity display area
(reserved for future models).
Mode
Auto Cooling Heating Fan Dry
The mode cycle depends on mode
setting in basic setting function.
Up/DownswingandLeft/Right
swingfunction.
Fanspeed,thecycletypeoffanspeed
can be set through basic setting.
Thursday
Set temp.
Mode Menu Swing
Indoor temp.
Qty. online
Standby
Defrost Master
Outdoor temp. 36 °F
Outdoor humidity 32%RH
70 °F
32%RH
Indoor humidity
76°F
10:30AM
01.01.2015
The quantity of indoor units connected
tothewiredcontroller.
Thursday
Set temp.
Mode Menu Swing
Indoor temp.
Qty. online
Standby
Defrost
Master
Outdoor temp. 36 °F
Outdoor humidity 32%RH
70 °F
32%RH
Indoor humidity
76°F
10:30AM
01.01.2015
Defrost function.
Thursday
Set temp.
Mode Menu Swing
Indoor temp.
Qty. online
Standby
Defrost Master
Outdoor temp. 36 °F
Outdoor humidity 32%RH
70 °F
32%RH
Indoor humidity
76°F
10:30AM
01.01.2015
Thestateoftheindoorunit,thisareacan
also display “operation”
Thursday
Set temp.
Mode Menu Swing
Indoor temp.
Qty. online
Standby
Defrost Master
Outdoor temp. 36 °F
Outdoor humidity 32%RH
70 °F
32%RH
Indoor humidity
76°F
10:30AM
01.01.2015
Thestateofwiredcontroller,this
area also can display”slave”. “Master”
meansthewiredcontrolleristhemain
controller,“Slave”meansthewired
controller only can control parts of
functions.
Thursday
Set temp.
Mode Menu Swing
Indoor temp.
Qty. online
Standby
Defrost Master
Outdoor temp. 36 °F
PM2.5 A++
70 °F
32%RH
Indoor humidity
76°F
10:30AM
01.01.2015
Reserved function.
Filter clean reminder. Default = 500
running hours.
EnergySavingfunction.Thisiconwillbe
displayedonlywhenenergysavingfunc-
tion is set.
Motion sensor on.
MotionSensingairowfollowing
human.
MotionSensingairowavoidhuman.
Thursday
Set temp.
Mode Menu Swing
Indoor temp.
Qty. online
Standby
Defrost Master
Outdoor temp. 36 °F
Outdoor humidity 32%RH
70 °F
32%RH
Indoor humidity
76°F
10:30AM
01.01.2015
Outdoor temperature display
area.Itcanbesetwhether
display or not.
Thursday
Set temp.
Mode Menu Swing
Indoor temp.
Qty. online
Standby
Defrost Master
Outdoor temp. 36 °F
Outdoor humidity 32%RH
70 °F
32%RH
Indoor humidity
76°F
10:30AM
01.01.2015
Outdoor humidity display area.
Itcanbesetwhetherdisplayor
not. (Not valid for mini-split and
multi-split units.)

Page 4 WIRED CONTROLLER
ENGLISH
Wired Controller Wiring Instructions
INSTALLATION
Wired Controller Wiring
1.Holdthefrontofthecontroller,pushdownthebackcoverto
open the back cover of the controller.
2.Putcommunicationwirethroughtheholeinthebackcover.
3.Fix the back cover.
4.ConnectcommunicationwiretoCON4portofwired
controller.
5.Finallyputthefrontcoverofwiredcontrollertobackcover
to complete the installation.
Communication Wiring
Communication Wiring
Length
Dimension of Wiring
0~100 ft (0~30m) 22AWG(0.3mm2)x3-core
shieldedwire
100~200 ft (30~60m) 20AWG(0.5mm2)x3-core
shieldedwire
200~300 ft (0~90m) 18AWG(0.75mm2)x3-core
shieldedwire
300-400 ft (90~120m) 16AWG(1.25mm2)x3-core
shieldedwire
400~500 ft (120~150m) 14AWG(2mm2)x3-core
shieldedwire
Note: the battery is non-removable and recharges while the unit
is connected to power in order to save user settings if there is a
power outage.
3 3/4 (95.74)
1 3/8 (34)
5/8 (15.26)
3 11/16 (94)
4 3/4 (120)
1 7/8 (47.4)
13/16 (21.44)
4 3/4 (120)
7/16 (11.8)
11/16 (17.8)
7/16 (11.87) 9/16 (14.03)

WIRED CONTROLLER Page 5
ENGLISH
OPERATION
Settings & Functions
Schedule options include segmented timing and random
timing. It can be selected through display setting. The default
is segmented timing.
Segmented timing (recommended setting)
Thursday
Return Enter Main
10:30
Display Setting
Language
English
°C
Spanish
°F
French
Russian
Italian
Segmented timing
Chinese
Random timing
Schedule
Temp. unit
AM
01.01.2015
1.Note: The segmented timing will only operate in cooling or
heating mode. will not execute in fan mode. Time can be
adjustedin24hours,thedefaultformatoftimedisplayis
12-hour.Temperaturecanbeadjustedfrom60°Fto86°F,
“OFF”canalsobesetmeaningpowero.
2.First,theleftandrightarrowsashbesidethetimeof
wake-up.Nextpresstheenterkey,thearrowswillbestatic,
continuetopressleftorrightkeytoadjusttimefollowedby
theenterkeytoconrm.Thefourdirectionkeyscanmove
thearrowwhentheyareashing.
3.Pressokkeytoconrmthesettingaccordingtheprompt
belowthescreen.
4.Thedefaultvalueisthesameinthegurebelow.
Pressthemenukeyinthemaininterfacetoenterthe
operation settings menu.
Weekly Program 1.KeeppressingLeft/Rightkeytospeeduptimeadjustment.
Random timing
Thursday
Return Enter Main
10:30
Display Setting
Language
English
°C
Spanish
°F
French
Russian
Italian
Segmented timing
Chinese
Random timing
Schedule
Temp. unit
AM
01.01.2015
1.When +ashesinthescheduleeditinginterface,press
the enter key to enter the setting interface.
Thursday
Schedule
Sleep
Time
Swing
Extra function
Humidity control
Error code
Display setting
Service help
Installer setting
Mode Menu Swing
10:30Menu AM
01.01.2015
Thursday
Schedule
Sleep
Time
Swing
Extra function
Humidity control
Error code
Display setting
Service help
Installer setting
Return Enter Main
10:30Menu AM
01.01.2015
Thursday
Cancel Ok
10:30
Schedule
AM
01.01.2015
Heat
(mon.-fri.) Cool
(mon.-fri.) Heat
(sat.-sun.) Cool
(sat.-sun.)
Wake
6:00 am 70°F OFF 70°F OFF
Leave
8:00 am 70°F 85°F 62°F 62°F
Return
6:00 pm 70°F 85°F OFF 78°F
Sleep
10:00 pm 62°F 82°F 62°F 62°F
Thursday
Cancel Ok
10:30Schedule AM
01.01.2015
1Weekday
+Add
-Delete
2Everyday
3Monday
3Tuesday
No. Week Mode Temp
26.0°F 12:47 N
22.0°F 14:22 Y
19.0°F 15:34 N
20.0°F 09:25 Y
Time Enable
Press for page turning
Thursday
Cancel Ok
10:30Schedule Setting AM
01.01.2015
Mode On/OffTemp
20.5
°F 14:20 NON
Time Week
Enable/
Disable
Auto
Cool
Week
day
Mon.
Wed.
Fri.
Sun.
Tue.
Thu.
Sat.
Every
day
Heat
Fan
Dry
1.Intelligentmode,76°F,powero,12:00,enableand
weekdayisdefault.
2.Iftheschedulethatyouaresettinghasbeensetbefore,the
interfacewillpromptyou thattheschedulealreadyexists.
You need to cancel it or change the repeated parameters.
The Timer ON of this Unit is in conict
with the existing Timer OFF, please
reset the Timer ON.
Cancel Enter
The Timing of this Unit has been set.
Do you want to replace the previous
setting?
Cancel Enter
The Timer OFF of this Unit is in conict
with the existing Timer ON, please
reset the Timer OFF.
Cancel Enter
The Timing has been set, please revise
relevant parameters.
Cancel Enter
1.Aftersetting,pressOktoconrmthetimingandgobackto
schedule interface simultaneously.
Presstheenterkeytodeleteaschedulewhen“ -”ashes.
Thedeleteinterfacewilldisplay.Nowchoosethenumberyou
wanttodeletethroughthedirectionkeysandenterkey.
Cancel Enter
Please select the No. you want to delete.
all 1 2 4 6 83 5 7
910 11 13 15 1712 14 16
18 19 20 22 24 2621 23 25
27 28 29 31 33 3530 32 34

Page 6 WIRED CONTROLLER
ENGLISH
Whenthetimeiconisashing,presstheenterkeytoenter
the time interface.
Presstheenterkeytoenterthesettinginterfacewhenthe
iconisashinginthemenu.
1.The default information for each function is decided by
indoorunitexceptchildlock.Childlockfunctionisoby
default.
2.MovethearrowsusingtheUp/DownorLeft/Rightkey.
Arrowswilldisplaystaticallywhenyoupressenterkey.Press
theLeft/Rightkeytochoose“ON”or“OFF”.Aftersetting,
pressUp/Downkeytoconrmandmovetotheaboveor
belowfunctiondirectlyorpresstheenterkeytosetagain.
3.Thecorrespondingfunction iconwilldisplayinthemain
interfacewhenafunctionissetinextrafunction.
4.Some functions are not available for some models. These
willbegreyedout.TurboandQuietfunctionconictand
can’tbothbeon.Settingonewilldisabletheother.Thisis
thesameforhealthairowupanddown.
5.Important: When child lock is set to ON, the interface skips
to the main display automatically. The function also can be
set or canceled by pressing the Left and Right keys together
for 5s in the main interface.
Presstheenterkeytoentertheerrorcodedisplayinterface
whentheiconisashinginthemenu.
1.Up/Downkeytochoosetheunit.Left/Rightkeytochange
pages.
2.Onecurrenterrorcodewilldisplayanduptothirtyvepast
errorcodeswilldisplayforeachunit.
3.PresstheLeftandRightkeystogetherfor5sto clearaway
theerrorhistoryinformationofthecurrentunit.Press
UpandDownkeystogetherfor5stoclearawaytheerror
history information of all the units on line. The combination
method is only valid in error interface.
Time
Extra Function
Error Code
1.The defaultdateisDecember 12th,2014,thetimeis
12:00PMandtheweekisFriday.Adjustingsettingsisthe
samewayasscheduleadjusting.
2.The defaultformatis12-hourandMonth/Day/Year.
Thursday
Return Enter Main
10:30
Time
01.01.2015 AM
Time setting 2015
year
AM 9
hour
11
month
35
minute
30
day
Mon.
week
12-hour 24-hour
Year/Month/Day
Day/Month/year
Month/Day/Year
Date format
setting
Thursday
Return Enter Main
10:30
Extra Function
01.01.2015 AM
Quiet Ventilation
Turbo Health
Child lock Quick start
Forced
defrost Night quiet
NO NO
OFF OFF
ON ON
OFF OFF
Thursday
Return Enter Main
10:30
Error Code 01.01.2015 AM
Current error
Error history
Error code:017 20/08/2014 11:20
Error code:017 18/08/2014 15:35
Error code:006 27/10/2013 13:56
Error code:012 20/05/2014 09:37
Error code:013 10/08/2014 23:14
Presstheenterkeytotheservicehelpinterfacewhentheicon
isashinginthemenu.
1.Passwordfunctionincludespasswordsettingandrecovery.
Thedefaultpasswordis841226. Whennishedentering
password,pressdirectionkeytocancelorenter,thenpress
enterkeytoconrm,orcontinuetopressenterkeyto
conrmafterinputtingsixnumbers.
Service Help
Thursday
Return Enter Main
10:30
Service & Help 01.01.2015 AM
Password
Help
Passwordrecovery
Passwordsetting
Howtosetchildlock?
Howtocleanlters?
Howtoinquireerrorcodes?
Howtosetfour-waycassetteangle?
1.Ifpassword recoveryisset, theinterfacewillpromptas
follows,thencancelorenter.
1.Helpfunctionisavailableforonlysomemodels.The
informationisgraywhenitisnotavailable.
Do you really want to password
recovery?
Cancel Enter

WIRED CONTROLLER Page 7
ENGLISH
Thursday
Return Enter Main
10:30
Swing 01.01.2015 AM
Type Up/Down
ON
Left/Right
OFF
Four-way
cassette
Angle
control
NotavailableinNorthAmerica.
Pressenterkeytoentertheinterfacewhenswingiconis
ashinginthemenu.Passwordisrequired.(Passwordis
841226).
1.Thedefaultinformationofswingtypeandanglecontrol
is decided by the indoor unit and is automatically decided
whenconnected.Whentypeandanglecontrol aresetin
adierentcombination,themaininterfacewilldisplay
correspondingiconandthenswingfunctionwillbeupdated
by indoor unit.
Sleep
Swing
2.Ifacombinationisnotavailable,theinformationwillbegray.
3.Ifnoswingisset,the swingkeyinthemaininterfaceisused
foradjustingthefanspeed.
4.IfUp/DownandLeft/Rightswingwithnoangleisset,swing
keyinthemaininterfacecontrolsopenandcloseofswing.
5.IfUp/DownandLeft/Rightswingwithangleisset,the
swingiconwillashafterpressingtheswingkeyinthemain
interface.NextpressLeft/Rightkeytoadjustangle.Swing
keyisusedforshiftingUp/DownswingandLeft/Right
swing.Thereisnooperationfor5safterswingiconashes,
theiconwill bestatic indicatingquittingadjustment.
6.Iftheindoorunit isafour-waycassettemodel,swing
functioninthemenuisinvalid. Swingkeyinthemain
interfaceisusedforchangingthedeector.Theorder
fourdeectors->deector1->deector2->deector3-
>deector4->fourdeectors.Thedeectorashesfor
5swhenitisselected,then pressLeft/Rightkeytoadjust
swingangleofthisdeectoratthesametime.
7.Angledenition:
Up/Downswing:1standsforangle1,2standsforangle2,3
standsforangle3,4standsforangle4,5standsforangle5,
1and2standforhealthairowup,4and5standsforhealth
airowdown,thecirculationof1->2->3->4->5->4->3->2-
>1standsforautomaticswing.
Up/Downswingwillbechangedinsequenceasfollows:
angle1->angle2->angle3->angle4->angle5->automatic
swing->angle1.
1
2
3
45
12345
Left/Rightswing:
Left/rightswingcanbeadjustedaspertheuser’s
requirement.Thecirculationof1->2->3->4->5->4->3->2-
>1standsforautomaticswing.
Not available for mini-split and multi-split.
Humidity Control
8.Thedefaultangleindierentmodesisasfollows:
Up/Downswing:
Auto Heating Cooling Dry Fan
Angle Angle1 Angle5 Angle1 Angle1 Angle1
Left/Rightswing:
Auto Heating Cooling Dry Fan
Angle Angle1 Angle1 Angle1 Angle1 Angle1
Four-waycassette:
Auto Heating Cooling Dry Fan
Deector Four
deectors
Four
deectors
Four
deectors
Four
deectors
Four
deectors
Angle Angle1 Angle5 Angle1 Angle1 Angle1

Page 8 WIRED CONTROLLER
ENGLISH
Indoor temperature display
Ifthefunctionisturnedon,themaininterfacewilldisplaythe
indoortemperature.Ino,themaininterfacewillnotdisplay
indoor temperature.
Indoor humidity display
It is only available for some models.
Outdoor temperature display
It is only available for some models.
Outdoor humidity display
It is only available for some models.
Presstheenterkeytoenterthefunctionwhentheiconis
ashinginthemenu.
Details
Thecorrespondingparameterinformationwillbedisplayedin
thisfunction.Up/Downkeytoadjustunitnumber,Left/Right
key to turn page. Some information is gray that can not be
inquired.
Installer Setting
Presstheenterkeytogotothenextinterfacewhentheiconis
ashinginthemenu.
1.Screen saving
There arevescreensavingtimeoptions.Thetime
indicateshowlongthescreenlightstaysonafterno
operation.”Cancel”meansthatthe screenlightwillnevergo
o.
2.Brightness
The function is used for controlling the light intensity.
Language
Only valid for some models.
Temp. unit
Celsius or Fahrenheit can be selected through this function.
Schedule
Segmented timing or Random timing can be set. Segment
timing is highly recommended.
Display Setting
Thursday
Return Enter Main
10:30
Display Setting
Screen
saving
15s
30%
30s
50%
1min
60%
3mins
80%
Cancel
100%
Bright
-ness
AM
01.01.2015
Thursday
Return Enter Main
10:30
Display Setting
Language
English
°C
Spanish
°F
French
Russian
Italian
Segmented timing
Chinese
Random timing
Schedule
Temp. unit
AM
01.01.2015
Thursday
Return Enter Main
10:30
Display Setting
Outdoor temp display
Indoor humidity display
Indoor temp display
Outdoor humidity display
PM2.5 display
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
AM
01.01.2015
Thursday
Return Enter Main
10:30
Details
01.01.2015 AM
Mode Cool
Auto
07
A++
Speed
Indoor address
PM2.5
unit
6
Address setting
Thedefaultpasswordis841226. Thecommunicationaddress
canbesettwoways.Onewayisthewiredcontroller.The
otherwayisthewiredcontrollerwithautomaticcompeting
set.Centraladdressandcommunicationaddressbetween
indoorandoutdoorcanbothbe adjustedaccordingtothe
individual situation.
Thursday
Return Enter Main
10:30
Address Setting
01.01.2015 AM
Comm. Add.
setting
Central address
4
68
Communication address
between
indoor and outdoor unit:
unit
6
wired controller + auto
wired controller
Thursday
Return Enter Main
10:30
Details
01.01.2015 AM
Central address:
113
37
unit
6Communication address between indoor
and outdoor unit:
37

WIRED CONTROLLER Page 9
ENGLISH
Basic setting
The information of model is controlled by the indoor unit and
can not be changedas is the same to capacity information.
Normal fan
The default information is controlled by the indoor unit.
Mode selection
Dierentmodecombinationscanbesetaccordingtoeach
application.
New/old protocol
Self-adaption is default. The function is used for basic
settings.Donotresetit,orthecontrollermaynotwork
normally.
Power o memory
Ifthefunctionisseton,thewiredcontrollerwillmaintainthe
previousstateintemperature,fanspeed,etcfrominoutage
topowerupagain.
Master/Slave set
Wired controller can be set as master controller or slave
controller through this function. Slave controller can only
control some of the functions.
Ambient temperature revision
Therevisionvalueisonlyvalidforwiredcontrollerambient
temperature.Pressenterkeytomakethearrowsstaticand
adjustthetemperatureusingtheLeft/Rightkey.
Thursday
Return Enter Main
10:30
Basic Setting
AM
01.01.2015
Mode
selection
Auto Heat Dry Cool Fan
Heat Dry Cool Fan
Cool Heat Fan
Auto Bypass Recovery
Heat only
Hot water
Dry Cool Fan
Thursday
Return Enter Main
10:30
Basic Setting
AM
01.01.2015
Power off
memory
Outdoor fan
xed speed
Master/Slave
set
grade
ON OFF
Slave
rotational speed
Master
Thursday
Return Enter Main
10:30
Basic Setting
AM
01.01.2015
Ambient temp.
revision
Twin energy
judgement
condition
ON OFF
4 group
2 group
3 group
1 group
- 3.5 º F
Indoor temperature collection
Theambienttemperaturemaybereadfromthewired
controller or the indoor unit through this setting. The same for
indoor humidity reading.
Inbasicsettinginterface,pressUp/Downkeytoadjust
unitnumber;pressLeft/Rightkeytomovethecursor.
Some functions are not available for some models and the
information is gray.
ECO
NOTE:Theenergysavingdefaultparametersarelistedbelow:
74°FLowesttemperaturelimitofCoolingandDrymode.
78°FHighesttemperaturelimitofHeatingmode.
74°F–86°FTemperatureadjustmentrangeinCoolingandDry
mode.
Fourdirectionkeyscanmovethecursor,whenthearrows
ash,pressenterkeytostoptheashingandpressLeft/
Rightkeytoadjustthevalue,thenpresstheenterkeyagain
toconrm.AftersettingECOfunction,thetemp.adjustment
willbelimited.Ifoverrunisset,thetemp.canbeadjustoutof
ECOrangeinallowabletime.
Thursday
Return Enter Main
10:30
Basic Setting AM
01.01.2015
unit
6
Available
Wired controller
Wired controller
Unavailable
Indoor unit
Indoor unit
Indoor hum.
collection
Indoor temp.
collection
Wi module
Thursday
Return Enter Main
10:30
ECO
AM
01.01.2015
ON
Setting
Range of temp.
The highest limit
of heating
The lowest limit
of cooling/dry
OFF
Temp.
ECO 75.0ºF
75.5ºF
Thursday
Return Enter Main
10:30
ECO AM
01.01.2015
ON
No overrun
Type
permitted
OFF
Temp.
ECO 2
hour
15
min
Thursday
Return Enter Main
10:30
Basic Setting AM
01.01.2015
Breeze
Quiet fan
Auto fan
Auto fan
High speed fan
Super fan ON
ON
ON
ON
ON
1
OFF
OFF
OFF
OFF
2 3
Normal
fan
unit
6
OFF

Page 10 WIRED CONTROLLER
ENGLISH
Running time
The function records both continuous running time and total
running time. When the bottom color of “Clear” changes to
white,pressenterkeytocleartheaccumulativerunningtime.
Vip priority choice
The function is only available for some models.
Special setting
Whenthethermostatisconnectedtoducttypeindoorunit,
thethermostatwilldetecttheavailablespeeds(static)the
unit is capable of.
Forexample,iftheunitonlyhave4staticsetting,thenitwill
onlyshow1-4.Thestaticpressurerangecanbereferencedin
the service manual of the corresponding indoors.
Thursday
Return Enter Main
10:30
Running Time
AM
01.01.2015
Continuous Running
Time 0014:22:53
0037:10:26
Total Running
Time
Clear
Clear
Thursday
Return Enter Main
10:30
Motion sensing
Motion sensing follow
Power off
when sensing
nobody in
Motion sensing evade
30 mins
15 mins
ON
ON
10 mins
OFF
OFF
OFF
AM
01.01.2015
Parameter setting
The function is only available for some models.
EEPROM setting
The function is only available for some models.
Motion sensing
The function is available for some models. When motion
sensingfolloworevadeisset,theangleofthedeectorwill
bedecidedbytheperson’scurrentlocation,thesettingswing
angle in the main interface is invalid at this time. When the
functionofautomaticpoweroisset,indoorunitwillpower
oaftersensingnobodyintheroomforthesettingtime.All
the functions in the interface are “OFF” by default.


www.Haier.com
HaierAmerica,
Wayne,NJ07470
©2016HaierAmericaTrading,LLC.
Model #: YR-E16b
IssuedDate:January2016
Other manuals for YR-E16b
1
Table of contents
Other Haier Temperature Controllers manuals
Popular Temperature Controllers manuals by other brands

Lumel
Lumel RE60 User Manual & Quick Start

sauermann
sauermann TH 210-R quick start guide

Solid State Cooling Systems
Solid State Cooling Systems TCS-110 product manual

Temperature@lert
Temperature@lert TM-WIFI220 user guide

Bryant
Bryant SYSTXBBECW01-A installation instructions

Tech Controllers
Tech Controllers EU-292n v2 user manual

Vaillant
Vaillant VRC 470 installation instructions

resideo
resideo ADEMCO TS300 Installation and operating instructions

Siemens
Siemens QMX3.P37 Technical principles

Shimaden
Shimaden SR70 Series instruction manual

ABB
ABB TSP341-N Detailed installation instructions

Dakota Digital
Dakota Digital 393050 manual