Document#101-0007 4 9/12/05
I. Installation
Mounting
1. DURING INSTALLATION, REMOVEALLMAJOR COMPONENTS FROM
THECHANGER.
2. Cut anopening inthe wallmeasuring aminimumof34-5/8" Hx9"Wfor RNS, 34-
3/4" H x 18-1/8" W for DRS and 20-3/4" H x 15" W for ER-60.
3. Caulk aroundthe outsideedge oftheopening.
4. Place thecabinetintheopeningand press until the flange is flush on allsides.
5. Fasten thecabinet bybolting orweldinga2"angle iron onboth sidesofthecabinet.
Hamilton will not be responsible for injury due to improper installation.
FACEPLATE: 38 5/8" H x 12" Wfor RNS, 38 1/4" H x 21 5/8" Wfor DRS and 24-3/4" H x 18"W for ER-
60.
Electrical
Thischanger isoperatedon 120VAC, 60 Hz.This changerusesa 5AMPCIRCUITBREAKER.This unit
maybe hard-wired withconduitif desired.AGROUNDFAULTINTERRUPTERISREQUIRED.The
recommendedGroundFaultInterruptershouldhavethefollowingspecifications:
• 120 VAC
• 15 AMP
• 6-10mAtrip level
• Shouldnottrip whenpower isremovedfrom circuit.
Attached to the main harness is a 1-pin white Molex connected to a white wire. There should be a bright
yellowtagattachedtothiswirewiththefollowingwarning:
WARNING: Forsecurityreasons,thisplug shouldremaindisconnected until
suchtime asyouneedtoutilize thehopper’s manualrunswitch.
Thereisnoneedtoconnectthisplugfornormaloperation.Ifforsomereasonyouwishtoutilizethemanualrun
switch,besureto unplug theMolex afterward.