handtmann 12507 User manual

Operating manual
Vacuum valve (closed type)
12507
BA_012507.05_EN
1 / 9 Albert Handtmann Armaturenfabrik GmbH & Co. KG 2017-06-14
1General.............................................................................................................................................................1
2Safety Information............................................................................................................................................2
3Delivery, Completeness, Storage ......................................................................................................................2
4Installation, Operation, Maintenance ...............................................................................................................3
5Additional Equipment.......................................................................................................................................8
1General
1.1 Manufacturer
Albert Handtmann Armaturenfabrik GmbH & Co. KG
Arthur-Handtmann-Str. 11; D-88400 Biberach
Tel.: +49(0) 73 51/3 42-0; Fax: +49(0) 73 51/3 42-44 80
E-Mail: sales.fit[email protected]
1.2 Proper application
Vacuum valves are used in the food, beverage, pharmaceutical and chemical industries.
They are suitable for the protection of tanks and other closed systems against negative
pressure.
During installation, operation and maintenance please pay attention to the generally
accepted safety regulations as well as to the operating instructions.
1.3 Misuse
Misuse is
Misuse is:
•Application in different operating conditions as intended for the specific type.
•Installation, operation and maintenance by unqualified staff.
•Any unauthorized modification of the valve or a valve component.
•On-observance of the operating instructions.
Any misuse will automatically lead to a loss of right to claim under guarantee as well as
any liability.
1.4 Duties of operator
The operator has to make sure that:
•The valve/component is operated properly and only in functional condition.
•The legal requirements are kept during operation and maintenance.
•Only sufficiently qualified and authorized staff maintain the valve/component.
•The staff responsible for operation and maintenance know and obey the
operating instructions and in particular the safety advice.
•The safety and warning signs remain on the valve/component and are
always legible.

Vacuum valve (closed type)
12507
BA_012507.05_EN
2017-06-14 Albert Handtmann Armaturenfabrik GmbH & Co. KG 2 / 9
2Safety Information
Notice and Safety
The following safety advice is an addition to existing national regulations and laws for
accident prevention. Existing regulations and laws for accident prevention always have to
be adhered to. Pay attention to the specific regulations and laws in your country.
The safety advice does not take into account:
•Coincidences and events that may occur during assembly, operation and
maintenance.
•Local safety regulations in responsibility of the operator.
Basic safety advice
Requirements for a proper function of the valve/component:
•Proper transportation and storage
•Installation and setting into operation by authorized staff
•Operation according to these operating instructions – proper application
•Proper and regular maintenance
WARNING
Warning – general dangers!
To avoid danger for health and life the following safety instructions
strictly have to be obeyed.
•Assembly and setting into operation only by qualified staff.
•Instruction and supervision by the operator.
•Keeping of technical and electrical data as specified in the operating instructions.
•Guarantee the electric safety of external devices.
•Keep legal regulations.
Non-observance may lead to the following dangers:
•Malfunction of the valve/component respectively of the plant.
•Danger for persons due to electrical, mechanical and chemical affects.
•Danger for the environment due to possible leakage of dangerous media.
3Delivery, Completeness, Storage
•Check the data of the delivery note for factual correctness and the material for
completeness. We regret that money cannot be refunded after purchase.
•Always check the material for transport damages. Possible damages have
to be informed immediately.
•Store the material in a dry place and if possible in its original packaging.

Vacuum valve (closed type)
12507
BA_012507.05_EN
3 / 9 Albert Handtmann Armaturenfabrik GmbH & Co. KG 2017-06-14
4Installation, Operation, Maintenance
Important notice !
•Valve/component suitable for vertical installation.
•Valve opens at a negative pressure of 3-5 mbar (30-50 mm WC).
Pressure compensation to ambient pressure by draw in air.
The valve will be closed by weight of valve cone.
•To avoid mistakes during assembly/disassembly, pay attention to the operating
instructions respectively the type plate.
4.1 Assembly instructions
Execution with heating device:
•The heating insets may only be connected according to attached scheme.
Pay attention to the connecting voltage!
•Do not remove the heating inset from the flange during function test
(heating capacity). It may get damaged by overheating.
Execution with lifting device:
•Pneumatic lifting cylinder for function test and for lifting the valve disk
during CIP.
•Suitable for treated compressed air, max. 6 bar.
•Throttle of air inlet has to be adjusted upon setting into operation.
•Compressed air supply: air hose Ø 6/4.
4.2 Operation
Type 12507
Construction with plastic valve disk DN 50 – DN 100
•Keep the valve clean.
•Lift the valve cone from time to time.
•Exchange the O-ring (1) carefully.
•Avoid any damages at the valve seat.
•Protect vacuum valves from any force influence from outside.
Any damage may affect the function.
•Admissible temperature: 40°C
Option: for higher temperatures use stainless steel valve cones.

Vacuum valve (closed type)
12507
BA_012507.05_EN
2017-06-14 Albert Handtmann Armaturenfabrik GmbH & Co. KG 4 / 9
Fig. 1: DN 50 – DN 65
Fig. 2: DN 80 – DN 100
1 Valve cone
2 O-ring
3 O-ring
4 Gasket
For all nominal diameters valid: The CIP-device is only optional available.

Vacuum valve (closed type)
12507
BA_012507.05_EN
5 / 9 Albert Handtmann Armaturenfabrik GmbH & Co. KG 2017-06-14
4.3 Maintenance
•Maintain the valve carefully, avoid any damages.
•Dismount the valve.
•Exchange the O-rings (1) and (2) do not distort.
Clean the grooves and sealing area.
– The maintenance should be executed at regular intervals of min. every year.
Depending on the operating conditions of the valves, these intervals may be
shorter.
– During maintenance pay attention to the assembly and safety instructions.
– Any maintenance work may be carried out only in a depressurized system.
In case of spare parts orders please inform us the order No.
Gasket material EPDM
4.4 Seals
Fig. 3: Type 12507 DN 50 - 65

Vacuum valve (closed type)
12507
BA_012507.05_EN
2017-06-14 Albert Handtmann Armaturenfabrik GmbH & Co. KG 6 / 9
Fig. 4: Type 12507 DN 80 - 100
10 Valve cone
20 O-ring
30 O-ring
40 Gasket
4.5 Spare parts
DN 12507
50 012507.00050LE
65 012507.00065LE
80 012507.00080LE
100 012507.00100LE
LE - EPDM

Vacuum valve (closed type)
12507
BA_012507.05_EN
7 / 9 Albert Handtmann Armaturenfabrik GmbH & Co. KG 2017-06-14
4.6 Identification of components
All vacuum valves (VV) must be provided with permanent identification of the component.
– Standard vacuum valves are provided with a setting value (4 mbar) specified by us
(opening pressure range 3-5 mbar)
Explanation of the identification:
Numerical
code AH VV xxxxx xxx yyy xx / xxxxx
AH VV xxxxx xxx yyy xx / xxxxx
Allocation 1 2 3 4 5 6
1 Manufacturer
2 Vacuum valve
3 Valve type
4 Nominal width / DN [mm]
5 Set negative pressure p [mbar]
6 Year of manufacture with manufacturing №

Vacuum valve (closed type)
12507
BA_012507.05_EN
2017-06-14 Albert Handtmann Armaturenfabrik GmbH & Co. KG 8 / 9
5Additional Equipment
Proxi mit y swi tch, i nd ucti ve
5.1 Proximity switch, inductive
Type make contact (NO); №106220 BES M12EE-PSC40B-S04G,
Nominal switching distance
>> with trip cam material steel
4 mm even
>> with trip cam material stainless steel 2,8 mm even
Supply current U 10 ...30 VDC
No-load current bedämpft / unbedämpft max. 10 mA/max. 5 mA
Operating current 200 mA
Potential drop U max. 2,5 V
Switching frequency 200 Hz
Reserve battery protection yes
Short-circuit proof yes
Construction size M12x1
Casing material Stainless steel
Temperature range - 25° C ... + 85° C
Enclosure rating IP 68
Indicator Multi-hole – LED
Fig. 5: Dimensions and connection scheme PNP

Vacuum valve (closed type)
12507
BA_012507.05_EN
9 / 9 Albert Handtmann Armaturenfabrik GmbH & Co. KG 2017-06-14
5.2 Heating insets
Heating insets
DN
Connection-
scheme №
Connection
voltage
Volt
Heating
capacity
Watt
Quantity
Rated power:
Volt Watt
Part №
50-100 11 125E23 24 11.5 2 24 23 105373
Fig. 6: E23, DN 50 – DN 100
Heating inset Ø6,5 x 40
Temperature
control unit