manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Hanna Instruments
  6. •
  7. Measuring Instrument
  8. •
  9. Hanna Instruments Champ HI 98106 User manual

Hanna Instruments Champ HI 98106 User manual

Other Hanna Instruments Measuring Instrument manuals

Hanna Instruments HI 2214 User manual

Hanna Instruments

Hanna Instruments HI 2214 User manual

Hanna Instruments HI 83140 User manual

Hanna Instruments

Hanna Instruments HI 83140 User manual

Hanna Instruments HI 99131 User manual

Hanna Instruments

Hanna Instruments HI 99131 User manual

Hanna Instruments HI96702C User manual

Hanna Instruments

Hanna Instruments HI96702C User manual

Hanna Instruments HI 981404N User manual

Hanna Instruments

Hanna Instruments HI 981404N User manual

Hanna Instruments HI 8014 User manual

Hanna Instruments

Hanna Instruments HI 8014 User manual

Hanna Instruments HI 99181 User manual

Hanna Instruments

Hanna Instruments HI 99181 User manual

Hanna Instruments HI 93726 User manual

Hanna Instruments

Hanna Instruments HI 93726 User manual

Hanna Instruments HA8424 User manual

Hanna Instruments

Hanna Instruments HA8424 User manual

Hanna Instruments Checker HI 711 User manual

Hanna Instruments

Hanna Instruments Checker HI 711 User manual

Hanna Instruments HI981954 User manual

Hanna Instruments

Hanna Instruments HI981954 User manual

Hanna Instruments HI 720 User manual

Hanna Instruments

Hanna Instruments HI 720 User manual

Hanna Instruments HI96709C User manual

Hanna Instruments

Hanna Instruments HI96709C User manual

Hanna Instruments HI 8314 User manual

Hanna Instruments

Hanna Instruments HI 8314 User manual

Hanna Instruments HI 1285-5 User manual

Hanna Instruments

Hanna Instruments HI 1285-5 User manual

Hanna Instruments Pronto HI 982401 User manual

Hanna Instruments

Hanna Instruments Pronto HI 982401 User manual

Hanna Instruments HI97717 User manual

Hanna Instruments

Hanna Instruments HI97717 User manual

Hanna Instruments edge pH User manual

Hanna Instruments

Hanna Instruments edge pH User manual

Hanna Instruments HI 99301 User manual

Hanna Instruments

Hanna Instruments HI 99301 User manual

Hanna Instruments HI 93703-11 User manual

Hanna Instruments

Hanna Instruments HI 93703-11 User manual

Hanna Instruments HI 84533 User manual

Hanna Instruments

Hanna Instruments HI 84533 User manual

Hanna Instruments HI 2211 User manual

Hanna Instruments

Hanna Instruments HI 2211 User manual

Hanna Instruments HI 96734C User manual

Hanna Instruments

Hanna Instruments HI 96734C User manual

Hanna Instruments HI 755 User manual

Hanna Instruments

Hanna Instruments HI 755 User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

IRIMO 984-6D-1 owner's manual

IRIMO

IRIMO 984-6D-1 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

HI 98106
Pocket-sized pH Meter
IST98106 R5 05/05
Champ®is a rugged pH tester with replaceable
electrode and renewable reference junction. The
instrument can be calibrated at one point by the
user, simply acting on the calibration trimmer.
Champ®is in compliance with the CE directives.
SPECIFICATIONS
Range 0.0 to 14.0 pH
Resolution 0.1 pH
Accuracy (@20°C/68°F) ±0.2 pH
Typical EMC Deviation ±0.1 pH
Calibration Manual, 1 point
Environment 0 to 50°C (32 to 122°F);
95% RH
Battery Type 4 x 1.5V alkaline
Battery Life approx. 800 hours of use
Dimensions 175 x 41 x 23 mm
(7.9 x 1.8 x 1")
Weight 78 g (2.7 oz.)
ACCESSORIES
HI 73106 Spare electrode
HI 70004P pH 4.01 solution (25 x 20 mL)
HI 70007P pH 7.01 solution (25 x 20 mL)
HI 70010P pH 10.01 solution (25 x 20 mL)
HI 7004M pH 4.01 solution, 230 mL bottle
HI 7007M pH 7.01 solution, 230 mL bottle
HI 7010M pH 10.01 solution, 230 mL
HI 70300M Storage solution, 230 mL bottle
HI 7061M Cleaning solution, 230 mL bottle
HI 731326 Calibration screwdriver (20 pcs)
Champis a registered Trademark of
Hanna Instruments
www.hannainst.com
CONDITIONING
• Remove the cap.
• To activate the electrode, immerse it in HI70300
storage solution for 2 hours.
CALIBRATION
• Immerse the tester in a pH buffer solution (for
example, HI 7007 pH 7.01 buffer).
• Allow the reading to stabilize
and with the supplied screw-
driver adjust the calibration
trimmer to read "7.0" pH.
The calibration is now complete.
OPERATION
• Remove the protective cap and
turn the Champ®on, by
sliding the ON/OFF switch on
the top of the meter.
• Immerse it into the solution to
be tested without exceeding
the maximum immersion level.
• Stir gently and wait for the
reading to stabilize.
• After use, switch the meter off, rinse the
electrode with water and store it with a few
drops of storage (HI70300) or pH 7 (HI7007)
solution in the protective cap. Always replace
the cap after use.
NEVER USE DISTILLED OR DEIONIZED WATER FOR
STORAGE PURPOSES.
• Large differences in pH readings (±1 pH)
could be due to lack of calibration or dry
electrode.
MAINTENANCE
The sensor should be kept moist at all times. For
this purpose, always keep wet the tissue inside
the protective cap.
In case of erroneous readings even after an
accurate conditioning and calibration, the refer-
ence junction might be contaminated or clogged.
Pull out 2 mm (1/8'') of the
cloth junction to renew the
electrode reference (it is rec-
ommended to cut the cloth
leaving always at least 2 mm
-1/8'' over the reference com-
partment) and recalibrate the
meter.
The cloth junction can be pulled out approxi-
mately 20 times. After that, the electrode should
be replaced.
ELECTRODE REPLACEMENT
For replacing the electrode contact your Dealer or
the nearest Hanna Service Center.
BATTERY REPLACEMENT
When display fades the batteries must be re-
placed. Slide off the battery compartment cover
and replace all four 1.5V alkaline batteries while
paying attention to the correct polarity.
Batteries should only be replaced in a nonhaz-
ardous area using the battery type specified in
this instruction manual.
WARRANTY
This meter is guaranteed for one year against defects in
workmanship and materials when used for their intended
purpose and maintained according to instructions. This war-
ranty is limited to repair or replacement free of charge.
Damages due to accident, misuse, tampering or lack of
prescribed maintenance are not covered. If service is re-
quired, contact the dealer from whom you purchased the
instrument. If under warranty, report the model number,
date of purchase, serial number and the nature of the fail-
ure. If the repair is not covered by the warranty, you will be
notified of the charges incurred. If the instrument is to be
returned to Hanna Instruments, first obtain a Returned Goods
Authorization Number from the Customer Service depart-
ment and then send it with shipment costs prepaid. When
shipping any instrument, make sure it is properly packaged
for complete protection.