HI758
Marine Calcium
INSTRUCTION MANUAL
Reagent Sets
HI758-26 Reagents for 25 Marine Calcium tests
Other Accessories
HI758-11 Marine Calcium Certified Standard Kit
HI731315 Glass Cuvettes and Caps for Checker®HC Colorimeters (2 pcs.)
HI731318 Cloth for wiping cuvettes (4 pcs.)
HI731339P 0.1 mL minipipette
HI731349P Tip for 0.1 mL minipipette (10 pcs.)
HI740028P 1.5V AAA batteries (12 pcs.)
HI70436M Deionized water (230 mL)
HI93703-50 Cuvette cleaning solution (230 mL)
Accessories
IST758 05/18
HI758 is warranted for a period of one year after date of purchase against defects in
workmanship and materials when used for their intended purpose and maintained according
to instructions. This warranty is limited to repair or replacement free of charge. Damage due
to accidents, misuse, tampering or lack of prescribed maintenance is not covered. If service
is required, contact your local Hanna Instruments Office. If under warranty, report the model
number, date of purchase, serial number and the nature of the problem. If the repair is not
covered by the warranty, you will be notified of the charges incurred. If the instrument is to
be returned to Hanna Instruments, first obtain a Return Goods Authorization number from the
Technical Service department and then send it with shipping costs prepaid. When shipping any
instrument, make sure it is properly packed for complete protection.
Before using Hanna Instruments products, make sure that they are entirely suitable for
your specific application and for the environment in which they are used. Operation of
these instruments may cause unacceptable interferences to other electronic equipment,
thus requiring the operator to take all necessary steps to correct such interferences. Any
variation introduced by the user to the supplied equipment may degrade the instrument’s
EMC performance. To avoid damages or burns, do not put the instrument in microwave
oven. For yours and the instrument safety do not use or store the instrument in hazardous
environments.
Recommendations for Users
Warranty
To conserve battery, the instrument shuts down after
10 minutes of non-use and 2 minutes after reading. One fresh battery
lasts for a minimum of 5000 measurements. When the battery is
dead the instrument will display “bAd” then “bAt” for 1 second
and then turns off. To replace the battery, turn the instrument off
by holding the button until the meter shuts off. Turn the instrument
upside down and remove the battery cover with a screwdriver.
Remove the battery from its location and replace it with a new one,
inserting the negative end first. Replace the battery cover and screw.
It is important that the sample does not contain any debris.
Whenever the cuvette is placed into the measurement cell, it must be
dry outside, and completely free of fingerprints, oil and dirt. Wipe it
thoroughly with HI731318 or a lint-free cloth prior to insertion.
Shaking the cuvette can generate bubbles, causing higher readings.
To obtain accurate measurements, remove bubbles by swirling or by
gently tapping the cuvette. Do not let the reacted sample stand for
too long after reagent is added, as accuracy will be affected. After the
reading, it is important to immediately discard the sample, otherwise
the glass might become permanently stained.
• Attach the pipette tip.
• Press the button down to the first stop.
• Immerse the pipette tip in the liquid approximately 2-3 mm.
• Slowly let the button move back to the original position, wait 2 seconds.
• Remove the pipette tip from the liquid.
• To dispense the liquid, place the pipette tip on the inside wall of the container.
• Slowly press the button down to the first stop.
• Wait until all of the liquid has been dispensed.
• Press the button down to the second stop, this will allow any remaining liquid to be dis-
pensed. First stop Second stopOriginal position
Minipipette Instructions:
Tips for an Accurate Measurement
Battery Management
10
mL
Functional Description
Errors and Warnings
Cover
Cuvette with cap
Cuvette holder
LCD Liquid Crystal Display
Operation Button
Under Range: A blinking “200” indicates that the reading is under
range.
Over Range: A blinking value of the maximum concentration indicates
the reading is over range. Dilute the sample and re-run the test.
Inverted Cuvette: The sample and the zero cuvette are inverted.
Low Battery: The battery is low and must be replaced soon.
Dead Battery: The battery is dead and must be replaced. Once this
indication is displayed, normal operation of the instrument will be
interrupted. Change the battery and restart the meter.
Light High: There is too much light to perform a measurement. Please
check the preparation of the zero cuvette.
Light Low: There is not enough light to perform a measurement.
Please check the preparation of the zero cuvette.
Please examine this product carefully. Make sure that the instrument is not damaged. If
any damage occurred during shipment, please contact your local Hanna Instruments Office.
Each HI758 meter is supplied complete with:
• Sample Cuvettes and Caps (2 pcs.)
• Reagents for 25 tests
• 1 mL syringe with tip
• Minipipette with tips
• Plastic pipette
• 1.5V AAA battery
• Instruction manual and Quick Reference Guide
Preliminary Examination
Range 200 to 600 ppm
Resolution 1 ppm
Accuracy ±6 ppm ±5% of reading @25 °C/77 °F
Light Source Light Emitting Diode @610 nm
Light Detector Silicon Photocell
Method Adaptation of the zincon method.
Environment 0 to 50 °C (32 to 122 °F); max 95% RH non-condesing
Battery Type 1.5V AAA (1 pc.)
Auto-Shut off After 10 minutes of non-use
Dimensions 86.0 x 61.0 x 37.5 mm (3.4 x 2.4 x 1.5”)
Weight 52 g (1.84 oz.)
Specifications
Thank You
Thank you for choosing a Hanna Instruments product. Please read this instruction
manual carefully before using the instrument.
For more information about Hanna Instruments and our products, visit
www.hannainst.com.
For technical support, contact your local Hanna Instruments Office or e-mail us at
[email protected].
Find your local Hanna Instruments Office on www.hannainst.com.
Measurement Procedure
Hanna Instruments reserves the right to modify the design, construction or appearance of
its products without advance notice.
• Turn the meter on by pressing the button.
All segments will be displayed. When the
display shows “Add”, “C.1” with “Press”
blinking, the meter is ready.
• Add 1 mL of HI7581 Reagent A to the
cuvette using the 1 mL syringe. Use
the plastic pipette to fill the cuvette
to the 10 mL mark with deionized
water and replace the cap. Invert
3-5 times to mix.
• Place the cuvette into the meter and close
the meter’s cap. Press the button. When the
display shows “Add”, “C2” with “Press”
blinking the meter is zeroed.
• Remove the cuvette from the meter and
unscrew the cap. Use the minipipette to
add 0.1 mL of sample to the cuvette.
• Add 1 packet of HI7582 Reagent B.
Replace the cap and shake vigorously for
15 seconds or until the powder is completely
dissolved. Allow air bubbles to dissipate for
15 seconds before taking a reading.
• Place the cuvette back into the meter and
close the meter’s cap. Press the button.
The meter displays concentration in ppm
of calcium. The meter automatically turns
off after 2 minutes.

Other manuals for HI 758

3

Other Hanna Instruments Measuring Instrument manuals

Hanna Instruments HI 140 Series User manual

Hanna Instruments

Hanna Instruments HI 140 Series User manual

Hanna Instruments HI 99121 User manual

Hanna Instruments

Hanna Instruments HI 99121 User manual

Hanna Instruments HI 93711 User manual

Hanna Instruments

Hanna Instruments HI 93711 User manual

Hanna Instruments HI 2221 User manual

Hanna Instruments

Hanna Instruments HI 2221 User manual

Hanna Instruments HI97771 User manual

Hanna Instruments

Hanna Instruments HI97771 User manual

Hanna Instruments PCA 310 User manual

Hanna Instruments

Hanna Instruments PCA 310 User manual

Hanna Instruments HI747 User manual

Hanna Instruments

Hanna Instruments HI747 User manual

Hanna Instruments HI 83414 User manual

Hanna Instruments

Hanna Instruments HI 83414 User manual

Hanna Instruments Total Chlorine HI 711 User manual

Hanna Instruments

Hanna Instruments Total Chlorine HI 711 User manual

Hanna Instruments HI 93711 User manual

Hanna Instruments

Hanna Instruments HI 93711 User manual

Hanna Instruments Checker HI721 User manual

Hanna Instruments

Hanna Instruments Checker HI721 User manual

Hanna Instruments HI97105 User manual

Hanna Instruments

Hanna Instruments HI97105 User manual

Hanna Instruments HI 9125 User manual

Hanna Instruments

Hanna Instruments HI 9125 User manual

Hanna Instruments C 214 User manual

Hanna Instruments

Hanna Instruments C 214 User manual

Hanna Instruments HI 98127 User manual

Hanna Instruments

Hanna Instruments HI 98127 User manual

Hanna Instruments HI 38018 User manual

Hanna Instruments

Hanna Instruments HI 38018 User manual

Hanna Instruments HI 4221 User manual

Hanna Instruments

Hanna Instruments HI 4221 User manual

Hanna Instruments HI 98140 User manual

Hanna Instruments

Hanna Instruments HI 98140 User manual

Hanna Instruments HI981400 User manual

Hanna Instruments

Hanna Instruments HI981400 User manual

Hanna Instruments HI99111 User manual

Hanna Instruments

Hanna Instruments HI99111 User manual

Hanna Instruments HI 96821 User manual

Hanna Instruments

Hanna Instruments HI 96821 User manual

Hanna Instruments HI83325 User manual

Hanna Instruments

Hanna Instruments HI83325 User manual

Hanna Instruments GROLINE MONITOR HI981420 User manual

Hanna Instruments

Hanna Instruments GROLINE MONITOR HI981420 User manual

Hanna Instruments HI 254 User manual

Hanna Instruments

Hanna Instruments HI 254 User manual

Popular Measuring Instrument manuals by other brands

Azbil MCW400A100 user manual

Azbil

Azbil MCW400A100 user manual

Johnson Controls RLBC Series user manual

Johnson Controls

Johnson Controls RLBC Series user manual

Northern Design PowerRail300 operating guide

Northern Design

Northern Design PowerRail300 operating guide

Ripley ODM OTDR 800 user guide

Ripley

Ripley ODM OTDR 800 user guide

Fieldpiece SOX3 Operator's manual

Fieldpiece

Fieldpiece SOX3 Operator's manual

Kane KANE458s Quick reference guide

Kane

Kane KANE458s Quick reference guide

Canon RA-532H Quick manual

Canon

Canon RA-532H Quick manual

Altronics Q0965 quick start guide

Altronics

Altronics Q0965 quick start guide

Endress+Hauser Proline Prowirl F 200 operating instructions

Endress+Hauser

Endress+Hauser Proline Prowirl F 200 operating instructions

Dixie DIGITAL ANGLE GAUGE manual

Dixie

Dixie DIGITAL ANGLE GAUGE manual

AEMC instruments K100 user manual

AEMC instruments

AEMC instruments K100 user manual

Center 530 instruction manual

Center

Center 530 instruction manual

Endress+Hauser Proline Prosonic Flow 91 operating instructions

Endress+Hauser

Endress+Hauser Proline Prosonic Flow 91 operating instructions

Sensorex SX40000 instruction manual

Sensorex

Sensorex SX40000 instruction manual

ANDalyze AND1100 user manual

ANDalyze

ANDalyze AND1100 user manual

Megger ATEC 210415 Series manual

Megger

Megger ATEC 210415 Series manual

Keysight Technologies N9322C user guide

Keysight Technologies

Keysight Technologies N9322C user guide

Tonghui U822 Operation manual

Tonghui

Tonghui U822 Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.