HI 83414 is a high accuracy, combined meter that benefits from Hanna’s years of experience as
manufacturer of analytical instruments.
The HI 83414 successfully combines turbidity and colorimetric measurements to meet the needs of
measuring the most important parameters of drinking water: turbidity and free/total chlorine. The
meter is especially designed for water quality measurements, providing reliable and accurate
readings on low turbidity and chlorine values. The HI 83414 meets and exceeds the requirements of
USEPA and Standard Methods both for turbidity and colorimetric measurements.
The instrument is based on a state-of-the-art optical system which guarantees accurate results,
assures long term stability and minimizes stray light and color interferences. It also compensates for
variations in intensity of the lamp, making no need for frequent calibration. The 525 nm intereference
filter of the colorimeter assures precise and repeatable results.
The 25 mm round cuvets made from special optical glass guarantee the repeatability of the
measurements.
Turbidity measurements
can be made in the 0.00 to 4000 NTU (Nephelometric Turbidity Units)
range when ratiometric measurements are used and in the 0.00 to 40.0 NTU range when non ratio
method is used. The instrument has an EPA compliance reading mode which rounds the reading to
meet EPA reporting requirements. Alternative EBC and Nephelos measuring units are available.
Depending on the measured sample and needed accuracy, normal measurement, continuous
measurement or signal averaging measurement can be selected.
A two, three, four or five-point calibration could be performed by using the supplied (<0.1, 15,
100, 750 and 2000 NTU) standards. When user prepared standards are used, the calibration points
can be modified.
Free or Total Chlorine measurements
can be made in the 0.00 to 5.00 mg/L (ppm) range.
With the powerful CAL CHECK™ function, the good performance of the instrument can be validated
at any moment by using the exclusive Hanna ready-made, NIST traceable standards.
A one-point calibration can be performed using the same cal check standard.
HI 83414 has complete G.L.P. (Good Laboratory Practice) functions that allows traceability of the
calibration conditions. The last calibration points, time and date can be checked.
HI 83414 has a user-friendly interface with an easy to understand, graphical LCD. All messages are
in plain text, easy to read and understand. Comprehensive contextual help is available at a simple
key press. All messages and helps are available in several languages. Confirmation and error acoustic
signals help the user during instrument operation. Furthermore, a tutorial mode of operation guides
the user step by step through the analysis process.
The instrument’s logging function offers complete information for the measurement. Up to 200
measurements can be stored in the internal memory and consulted at any time. In order to further
store or analyse, the data can be downloaded to a PC using the USB port.