manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Hanna Instruments
  6. •
  7. Measuring Instrument
  8. •
  9. Hanna Instruments HI 96108 User manual

Hanna Instruments HI 96108 User manual

Other Hanna Instruments Measuring Instrument manuals

Hanna Instruments HI 93735 User manual

Hanna Instruments

Hanna Instruments HI 93735 User manual

Hanna Instruments HI 95721C User manual

Hanna Instruments

Hanna Instruments HI 95721C User manual

Hanna Instruments HI 255 User manual

Hanna Instruments

Hanna Instruments HI 255 User manual

Hanna Instruments HI 991301 User manual

Hanna Instruments

Hanna Instruments HI 991301 User manual

Hanna Instruments HI 38022 User manual

Hanna Instruments

Hanna Instruments HI 38022 User manual

Hanna Instruments HI96786 User manual

Hanna Instruments

Hanna Instruments HI96786 User manual

Hanna Instruments HI 991301 User manual

Hanna Instruments

Hanna Instruments HI 991301 User manual

Hanna Instruments PICCOLO User manual

Hanna Instruments

Hanna Instruments PICCOLO User manual

Hanna Instruments HI 93734 User manual

Hanna Instruments

Hanna Instruments HI 93734 User manual

Hanna Instruments HI 83141V User manual

Hanna Instruments

Hanna Instruments HI 83141V User manual

Hanna Instruments 96708 User manual

Hanna Instruments

Hanna Instruments 96708 User manual

Hanna Instruments HI 991001 User manual

Hanna Instruments

Hanna Instruments HI 991001 User manual

Hanna Instruments HI 4110 User manual

Hanna Instruments

Hanna Instruments HI 4110 User manual

Hanna Instruments HI 9812-0 User manual

Hanna Instruments

Hanna Instruments HI 9812-0 User manual

Hanna Instruments HI96720C User manual

Hanna Instruments

Hanna Instruments HI96720C User manual

Hanna Instruments HI98198/10 User manual

Hanna Instruments

Hanna Instruments HI98198/10 User manual

Hanna Instruments HI 84432 User manual

Hanna Instruments

Hanna Instruments HI 84432 User manual

Hanna Instruments HI770 User manual

Hanna Instruments

Hanna Instruments HI770 User manual

Hanna Instruments HI 98180 User manual

Hanna Instruments

Hanna Instruments HI 98180 User manual

Hanna Instruments HI 98186 User manual

Hanna Instruments

Hanna Instruments HI 98186 User manual

Hanna Instruments HI97710 User manual

Hanna Instruments

Hanna Instruments HI97710 User manual

Hanna Instruments HI97769 User manual

Hanna Instruments

Hanna Instruments HI97769 User manual

Hanna Instruments HI 96821 User manual

Hanna Instruments

Hanna Instruments HI 96821 User manual

Hanna Instruments Checker Marine HI784 User manual

Hanna Instruments

Hanna Instruments Checker Marine HI784 User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

IRIMO 984-6D-1 owner's manual

IRIMO

IRIMO 984-6D-1 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

pHep®+
HI96108
Pocket-Sized
pHMeterwithATC
www.hannainst.com
SPECIFICATIONS
Range 0.0 to 14.0 pH
Resolution 0.1 pH
Accuracy (@20°C) ±0.1 pH
Calibration manual, 2 points
Temperature compensation
automatic, 0 to 50°C (32 to 122°F)
Environment RH 95% max;
0 to 50°C (32 to 122°F)
Batteries 3 x 1.5V alkaline
Life approx. 150 hours of use
Dimensions 150x30x21 mm
(5.9x1.2x0.8")
Weight 70 g (2.5 oz.)
ACCESSORIES
HI 7004M pH 4.01 solution (230 ml)
HI 7007M pH 7.01 solution (230 ml)
HI 7010M pH 10.01 solution (230 ml)
HI 70300M Storage solution (230 ml)
HI 7061M Cleaning solution (230 ml)
Dear Customer,
Thank you for choosing a Hanna product.
If you need additional technical informa-
tion, do not hesitate to e-mail us at
[email protected].
This instrument is in compliance with the
directives.
WARRANTY
This meter is guaranteed for six months against de-
fects in workmanship and materials when used for
its intended purpose and maintained according to in-
structions. This warranty is limited to repair or
replacement free of charge. Damages due to acci-
dent, misuse, tampering or lack of prescribed
maintenance are not covered. If service is required,
contact the dealer from whom you purchased the in-
strument. If under warranty, report the model number,
date of purchase, serial number and the nature of the
failure. If the repair is not covered by the warranty,
you will be notified of the charges incurred. If the
instrument is to be returned to Hanna Instruments,
first obtain a Returned Goods Authorization Number
fromtheCustomerServicedepartmentandthensend
it with shipment costs prepaid. When shipping any
instrument,makesureitisproperlypackagedforcom-
pleteprotection. IST96108 12/04
OPERATION
• Remove the protective cap. Do
not be alarmed if white crystals
appear around the cap. This is
normal with pH electrodes and
they dissolve when rinsed with
water.
• Turn the meter on sliding the
switch on the top.
• Immerse into solution up to
the max immersion level.
• Stir gently and wait until the
display stabilizes.
• After use, rinse the electrode
with water to minimize con-
tamination and store it with a
few drops of storage (HI70300)
or pH 7 (HI 7007) solution in
the protective cap.
DO NOT USE DISTILLED OR DEIONIZED
WATER FOR STORAGE PURPOSES.
• Large fluctuations in readings could be due
to lack of calibration, dry electrode or run-
down batteries.
Recommendations for users
Before using this product, make sure that it is entirely
suitable for the environment in which it is used. Operation
of this instrument in residential areas could cause
interference to radio and TV equipment. The glass bulb
at the end of the pH electrode is sensitive to electrostatic
discharge. Avoid touching this glass bulb at all times. Any
variation introduced by the user to the supplied equipment
may degrade the instrument's EMC performance. To avoid
electrical shock, do not use this instrument when voltages
at the measurement surface exceed 24 Vac or 60 Vdc.
To avoid damage or burns, do not perform any
measurement in microwave ovens.
CALIBRATION
• Immerse the tester up to the maximum
immersion level in pH 7 buffer (HI 7007)
• Allow the reading to
stabilize; using a
small screwdriver
adjust the pH7 cali-
bration trimmer to
read 7.0.
• Rinse the electrode with water and
immerse up to the maximum level in
pH4 (HI 7004) or pH10 (HI 7010).
• Allow the reading
to stabilize and
adjust the pH4/10
calibration trim-
mer to read 4.0
(or 10.0).
Calibration is now complete.
ALWAYSUSEFRESHBUFFERSFORCALIBRATION.
BATTERY REPLACEMENT
When the meter cannot be
switched on or the display
fades, pull out the battery com-
partment and replace all three
1.5V batteries, while paying
attention to their polarity.
Batteries should only be re-
placed in a safe area using
the battery type specified in
this instruction manual.
pHep is a registered Trademark of