Hanna Instruments Checktemp-Dir HI 98510-01 User manual

Checktemp®-Dip
HI 98509-01 • HI 98510-01
Precision Thermometers
with a Stainless Steel
Weighted Probe
Dear Customer,
Thank you for choosing a Hanna product.
Please read carefully this instruction manual be-
fore using the instrument. If you need additional
technical information, do not hesitate to e-mail us
at [email protected].
These instruments are in compliance with the
directives.
PRELIMINARY EXAMINATION
Remove the instrument from the packing material
and examine it carefully to make sure that no
damage has occurred during shipment. If there is
any damage, immediately notify your Dealer.
Each meter is supplied complete with battery and
instructions.
Note:Conserve all packing material until the in-
strument has been observed to function
correctly. Any defective item must be re-
turned in its original packing.
SPECIFICATIONS
Range -20.0 to 100.0°C / -4.0 to 212°F
Resolution 0.1°C
0.1°F (-4 to 199.9°F) / 1°F (200 to 212°F)
Accuracy
±0.5°C (-20 to 50°C) / ±0.9°C (outside)
±0.9°F (-4 to 122°F) / ±2°F (outside)
Probe Stainless steel, 3 m (9.9’) cable
Environment 0 to 50°C (32 to 122°F);
RH 95% max
Battery Type 1x1.5V AAA alkaline
Battery Life Approx. 3 years of use
Dimensions 106 x 58 x 19 mm (4.1x5.2x0.7")
Weight 80 g (2.8 oz.)
www.hannainst.com
GENERAL DESCRIPTION
Checktemp®-Dip is an accurate thermometer
provided with a fixed stainless steel probe with a 3
meter (9.9’) cable, and weighted so that it can be
dipped into any vat and tank and measure the tem-
perature at different depths.
Due to its hygienic stainless steel probe, it is ideal
for food applications, especially to check the tem-
perature inside wine casks and milk tanks.
Checktemp®-Dip can also be used for applications,
such as fish farms, water reservoirs and pools where
the operator can simply stand on the edge of the
water and throw the probe over.
The accuracy, in spite of the longer probe lead, is
an excellent ±0.3°C (±0.5°F).
In addition, you can check to make sure that your
thermometer is measuring the right temperature with
the Hanna Instruments’ exclusive Cal-Check®
technology.
Two models are available:
• HI 98509-01 (Checktemp®-Dip C) reads tempera-
ture in °C unit
• HI 98510-01 (Checktemp®-Dip F) reads tempera-
ture in °F unit
WARRANTY
These meters are guaranteed for one year against de-
fects in workmanship and materials when used for its
intended purpose and maintained according to instructions.
Probes are guaranteed for a period of six months. This
warranty is limited to repair or replacement free of charge.
Damages due to accident, misuse, tampering or lack of
prescribed maintenance are not covered. If service is re-
quired, contact the dealer from whom you purchased the
instrument. If under warranty, report the model number,
date of purchase, serial number and the nature of the
failure. If the repair is not covered by the warranty, you will
be notified of the charges incurred. If the instrument is to
be returned to Hanna Instruments, first obtain a Returned
Goods Authorization Number from the Customer Service
department and then send it with shipment costs prepaid.
When shipping any instrument, make sure it is properly
packaged for complete protection.
ISTCKTDIP R3 05/05
BATTERY REPLACEMENT
When Checktemp®-Dip cannot be switched on or
the display fades, remove the two screws, remove
the battery cover and change the 1.5V AAA bat-
tery, while paying attention to its polarity.
Replace the cover and tighten the two screws.
Battery should only be replaced in a safe area
and using an alkaline 1.5V AAA type battery.
OPERATION
• Turn the Checktemp®-Dip on and dip the probe in
the sample to be measured.
• Do NOT wrench the probe. If the cable is dam-
aged, the meter may have to be replaced.
• Wait a few seconds for the display to stabilize.
• After use, always switch the meter off
• Variations in readings or a fading display can
indicate a low battery level (see “Battery Re-
placement” section for details).
•Checktemp®-Dip should not be used for continu-
ous measurement at high temperatures. In fact,
even though Checktemp®-Dip can reach 100ºC
(212°F), prolonged measurements at high tem-
perature will reduce the sensor life dramatically.
The ideal operating temperature is in the -20 to
50ºC (-4 to 120ºF) range.
CALIBRATION CHECK SWITCH
Move the Cal-check®switch on the back of the
meter to the “Test” position.
The display should show 0.0°C (±0.5°C) or 32ºF
(±0.9°F).
Contact your dealer or the nearest Hanna Service
Center for recalibration, if necessary.
Move the Cal-check switch back to the “Run” po-
sition, and the display will return to normal mea-
surement mode.
Recommendations for Users
Before using this product, make sure that it is entirely suitable for the
environment in which it is used. Operation of this instrument in residential
areas could cause interference to radio and TV equipment. Any variation
introduced by the user to the supplied equipment may degrade the
instrument's EMC performance. To avoid electrical shocks, do not use this
instrument when voltage at the measurement surface exceeds 24 Vac or
60 Vdc. To avoid damage or burns, do not perform any measurement in
microwave ovens.

This manual suits for next models

1

Other Hanna Instruments Thermometer manuals

Hanna Instruments HI 935005 User manual

Hanna Instruments

Hanna Instruments HI 935005 User manual

Hanna Instruments HI145-20 User manual

Hanna Instruments

Hanna Instruments HI145-20 User manual

Hanna Instruments HI 955502 User manual

Hanna Instruments

Hanna Instruments HI 955502 User manual

Hanna Instruments HI 147-00 User manual

Hanna Instruments

Hanna Instruments HI 147-00 User manual

Hanna Instruments HI 9060 User manual

Hanna Instruments

Hanna Instruments HI 9060 User manual

Hanna Instruments HI 98121 User manual

Hanna Instruments

Hanna Instruments HI 98121 User manual

Hanna Instruments HI 935005 User manual

Hanna Instruments

Hanna Instruments HI 935005 User manual

Hanna Instruments Foodcare HI 93501 User manual

Hanna Instruments

Hanna Instruments Foodcare HI 93501 User manual

Hanna Instruments HI 93530 User manual

Hanna Instruments

Hanna Instruments HI 93530 User manual

Hanna Instruments Pool Line HI985394 User manual

Hanna Instruments

Hanna Instruments Pool Line HI985394 User manual

Hanna Instruments Foodcare HI 93501 User manual

Hanna Instruments

Hanna Instruments Foodcare HI 93501 User manual

Hanna Instruments HI 98509-1 User manual

Hanna Instruments

Hanna Instruments HI 98509-1 User manual

Hanna Instruments Foodcare HI 93501 User manual

Hanna Instruments

Hanna Instruments Foodcare HI 93501 User manual

Hanna Instruments HI 148 Series User manual

Hanna Instruments

Hanna Instruments HI 148 Series User manual

Hanna Instruments HI 99556 User manual

Hanna Instruments

Hanna Instruments HI 99556 User manual

Hanna Instruments HI 98701 User manual

Hanna Instruments

Hanna Instruments HI 98701 User manual

Hanna Instruments HI 955202 User manual

Hanna Instruments

Hanna Instruments HI 955202 User manual

Hanna Instruments HI 146-01 User manual

Hanna Instruments

Hanna Instruments HI 146-01 User manual

Hanna Instruments HI 93551 User manual

Hanna Instruments

Hanna Instruments HI 93551 User manual

Hanna Instruments HI 146-00 User manual

Hanna Instruments

Hanna Instruments HI 146-00 User manual

Hanna Instruments Pronto Plus HI99551 Series User manual

Hanna Instruments

Hanna Instruments Pronto Plus HI99551 Series User manual

Hanna Instruments HI 146-99 User manual

Hanna Instruments

Hanna Instruments HI 146-99 User manual

Hanna Instruments HI 8752 User manual

Hanna Instruments

Hanna Instruments HI 8752 User manual

Hanna Instruments HI 9271 User manual

Hanna Instruments

Hanna Instruments HI 9271 User manual

Popular Thermometer manuals by other brands

Technoline 433MHz Remote Thermo manual

Technoline

Technoline 433MHz Remote Thermo manual

Technoline WS 7003 manual

Technoline

Technoline WS 7003 manual

Delta OHM HD2205.2 manual

Delta OHM

Delta OHM HD2205.2 manual

Ink Bird IBBQ-4T manual

Ink Bird

Ink Bird IBBQ-4T manual

Digi-Sense ThermoLogR 93410-50 manual

Digi-Sense

Digi-Sense ThermoLogR 93410-50 manual

Lanaform Goby's world DT-100 instructions

Lanaform

Lanaform Goby's world DT-100 instructions

VOLTCRAFT IR 500-8S SE operating instructions

VOLTCRAFT

VOLTCRAFT IR 500-8S SE operating instructions

VOLTCRAFT IR-1600 CA operating instructions

VOLTCRAFT

VOLTCRAFT IR-1600 CA operating instructions

Geevon T208604 user manual

Geevon

Geevon T208604 user manual

nuVita 1015 Instructions for use

nuVita

nuVita 1015 Instructions for use

Shinko IRT-100-TF instruction manual

Shinko

Shinko IRT-100-TF instruction manual

MOB KC2444 user manual

MOB

MOB KC2444 user manual

Unisar Digital Thermometer user manual

Unisar

Unisar Digital Thermometer user manual

Lucky Reptile LTH-32 Operating	 instruction

Lucky Reptile

Lucky Reptile LTH-32 Operating instruction

Extech Instruments MO295 user guide

Extech Instruments

Extech Instruments MO295 user guide

TFA DUCKY instruction manual

TFA

TFA DUCKY instruction manual

Radiant Innovation TH06F manual

Radiant Innovation

Radiant Innovation TH06F manual

Microlife ProCheck FEVERGLOW IR1DY1-1-PRO instruction manual

Microlife

Microlife ProCheck FEVERGLOW IR1DY1-1-PRO instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.