manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Hanna Instruments
  6. •
  7. Thermometer
  8. •
  9. Hanna Instruments HI 146-99 User manual

Hanna Instruments HI 146-99 User manual

Other Hanna Instruments Thermometer manuals

Hanna Instruments HI 98811 User manual

Hanna Instruments

Hanna Instruments HI 98811 User manual

Hanna Instruments Checktemp series User manual

Hanna Instruments

Hanna Instruments Checktemp series User manual

Hanna Instruments Checktemp-Dir HI 98510-01 User manual

Hanna Instruments

Hanna Instruments Checktemp-Dir HI 98510-01 User manual

Hanna Instruments HI 98509-1 User manual

Hanna Instruments

Hanna Instruments HI 98509-1 User manual

Hanna Instruments HI 9061 User manual

Hanna Instruments

Hanna Instruments HI 9061 User manual

Hanna Instruments HI150-00 User manual

Hanna Instruments

Hanna Instruments HI150-00 User manual

Hanna Instruments Checktemp 1 User manual

Hanna Instruments

Hanna Instruments Checktemp 1 User manual

Hanna Instruments Foodcare HI 93501 User manual

Hanna Instruments

Hanna Instruments Foodcare HI 93501 User manual

Hanna Instruments HI 149-00 User manual

Hanna Instruments

Hanna Instruments HI 149-00 User manual

Hanna Instruments HI 9060 User manual

Hanna Instruments

Hanna Instruments HI 9060 User manual

Hanna Instruments HI 99550-00 User manual

Hanna Instruments

Hanna Instruments HI 99550-00 User manual

Hanna Instruments HI 147-00 User manual

Hanna Instruments

Hanna Instruments HI 147-00 User manual

Hanna Instruments Checkfridge HI147-00 User manual

Hanna Instruments

Hanna Instruments Checkfridge HI147-00 User manual

Hanna Instruments HI145-00 User manual

Hanna Instruments

Hanna Instruments HI145-00 User manual

Hanna Instruments HI 935005 User manual

Hanna Instruments

Hanna Instruments HI 935005 User manual

Hanna Instruments HI 93551R User manual

Hanna Instruments

Hanna Instruments HI 93551R User manual

Hanna Instruments Foodcare HI 93501 User manual

Hanna Instruments

Hanna Instruments Foodcare HI 93501 User manual

Hanna Instruments HI 146-00 User manual

Hanna Instruments

Hanna Instruments HI 146-00 User manual

Hanna Instruments Pronto Plus HI99551 Series User manual

Hanna Instruments

Hanna Instruments Pronto Plus HI99551 Series User manual

Hanna Instruments HI145-20 User manual

Hanna Instruments

Hanna Instruments HI145-20 User manual

Hanna Instruments HI 151-00 User manual

Hanna Instruments

Hanna Instruments HI 151-00 User manual

Hanna Instruments HI 935005 User manual

Hanna Instruments

Hanna Instruments HI 935005 User manual

Hanna Instruments HI 935005 User manual

Hanna Instruments

Hanna Instruments HI 935005 User manual

Hanna Instruments HI 955501 User manual

Hanna Instruments

Hanna Instruments HI 955501 User manual

Popular Thermometer manuals by other brands

Benetech GM900 instruction manual

Benetech

Benetech GM900 instruction manual

Parton PTD-400 manual

Parton

Parton PTD-400 manual

GAME 15900 owner's manual

GAME

GAME 15900 owner's manual

scigiene FP-180 instruction manual

scigiene

scigiene FP-180 instruction manual

Ametek Land UNO U1 600/1600C-L user guide

Ametek Land

Ametek Land UNO U1 600/1600C-L user guide

Delton 981A instruction manual

Delton

Delton 981A instruction manual

Taylor 5286498 instruction manual

Taylor

Taylor 5286498 instruction manual

Baker MM2P instruction manual

Baker

Baker MM2P instruction manual

Chino IR-FA Series instructions

Chino

Chino IR-FA Series instructions

Vive DMD1010 user manual

Vive

Vive DMD1010 user manual

Tarmo 320281 manual

Tarmo

Tarmo 320281 manual

Citizen CTD 504 instruction manual

Citizen

Citizen CTD 504 instruction manual

TFA 14.1500 instruction manual

TFA

TFA 14.1500 instruction manual

Gotemp THB4002 user guide

Gotemp

Gotemp THB4002 user guide

GREISINGER G 1202 Quick reference guide

GREISINGER

GREISINGER G 1202 Quick reference guide

Amprobe TMD-53W user manual

Amprobe

Amprobe TMD-53W user manual

Trotec BP10 operating manual

Trotec

Trotec BP10 operating manual

Radiance instruments RT616 Series product manual

Radiance instruments

Radiance instruments RT616 Series product manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

www.hannainst.com
Dear Customer,
Thank you for choosing a Hanna product.
Please read carefully this instruction manual before using
the meter.
If you need additional technical information, do not hesitate
to e-mail us at [email protected].
This instrument is in compliance with the directives.
PRELIMINARY EXAMINATION
Hanna Instruments reserves the right to modify the design, construction
and appearance of its products without advance notice.
Remove the instrument from the packing material and
examine it carefully. If any damage has occurred during
shipment, immediately notify your Dealer or the nearest
Hanna Customer Service Center.
The meter is supplied with battery and instructions.
Note: Conserve all packing material until the instrument
has been observed to function correctly. Any defective
item must be returned in its original packing.
GENERAL DESCRIPTION
This instrument is specially designed to meet the needs of
simple continuous monitoring of temperature.
The housing has been completely sealed against dust and
humidity with IP65 rating.
Simply hang the meter right above the sample to be tested
for continuous measurement.
The probe is easy to clean and requires little maintenance.
A protected switch allows a quick check of the meter accuracy
at any time.
FUNCTIONAL DESCRIPTION
Instruction Manual
HI146-99 Thermometer
1. Molded eye
2. Temperature Probe
3. Liquid Crystal Display
SPECIFICATIONS
Range -50.0 to 150.0°C
Resolution 0.1°C
Accuracy ±0.3°C (-20 to 90°C)
±0.5°C (outside)
Typical EMC Deviation ±0.3°C
Probe Stainless steel probe with 2 m (6.6’) cable
Battery Type 1 x 1.5V AA, alkaline
Battery Life approx. 5 years of use
Casing IP65
Environment 0 to 50°C (32 to 122°F); RH 100%
Dimensions 86 x 110 x 43 mm (3.4 x 4.3 x 1.7’’)
Weight 150 g (5.3 oz.)
OPERATION
• Dip the probe in the sample to be
measured. An immersion level of 4 cm
(1 ½") is recommended.
• Do NOT immerse the probe handle.
• Do NOT wrench the probe or put
heavy objects on the cable. If the
cable is damaged, the meter needs
to be replaced.
• Wait for a few seconds for the display
to stabilize.
• Variations in readings or fading dis-
play can indicate a weak battery.
CALIBRATION CHECK SWITCH
• Remove the rear cover (see also “Battery replacement”
section).
• Move the internal switch to the “TEST” position.
• The display should show 0.0±0.3°C (contact the near-
est Hanna Service Center for recalibration, if necessary).
OPERATIONAL GUIDE • To return to measure mode, move back the switch to
“MEAS” position.
• Reattach the cover while paying attention that the
gasket is in place before tightening the screws.
BATTERY REPLACEMENT
When the display fades, it is recommended to replace the
battery with a new one: unscrew the screws on the meter
back, remove the rear cover and change the battery, while
paying attention to its polarity.
Reattach the back cover while ensuring that the gasket is in
place before tightening the screws.
Battery should only be replaced in a safe area using one
1.5V AA alkaline type.
CE DECLARATION OF CONFORMITY
Recommendations for Users
Before using this product, make sure
that it is entirely suitable for the
environment in which it is used. Op-
eration of this instrument in residen-
tial areas could cause unacceptable
interferences to radio and TV equip-
ment. Any variation introduced by the
user to the supplied equipment may
degrade the instrument’s EMC per-
formance. To avoid electrical shock,
do not use this instrument when volt-
ages at the measurement surface
exceed 24 Vac or 60 VdcC. To avoid
damages or burns, do not perform
any measurement in microwave ov-
ens.
WARRANTY
This meter is warranted for two years against defects in workmanship and materials when
used for its intended purpose and maintained according to instructions.
The probe is warranted for a period of six months.
This warranty is limited to repair or replacement free of charge. Damages due to accident,
misuse, tampering or lack of prescribed maintenance are not covered.
If service is required, contact the dealer from whom you purchased the instrument. If under
warranty, report the model number, date of purchase, serial number and the nature of the
failure. If the repair is not covered by the warranty, you will be notified of the charges
incurred. If the instrument is to be returned to Hanna Instruments, first obtain a Returned
Goods Authorization Number from the Customer Service department and then send it with
shipment costs prepaid. When shipping any instrument, make sure it is properly packaged for
complete protection.
IST146-99R1 05/05