Hantek 4032L User manual

User’s Guide
Hantek4032L
PC USB Logic Analyzer
www.hantek.com

Content
General safety summary...............................................................................1
Introduction....................................................................................................2
Chapter 1 Getting started..............................................................................3
1.1 System Requirements..........................................................................................4
1.2 Installing Software................................................................................................5
1.3 Installing Driver....................................................................................................8
1.4 User Interface .................................................................................................... 11
Chapter 2 Menu............................................................................................12
2.1 File.....................................................................................................................13
2.2 View................................................................................................................... 13
2.3 Setup .................................................................................................................14
2.4 Analyzer.............................................................................................................14
2.5 Help ...................................................................................................................15
Chapter 3 Advanced....................................................................................16
3.1 Control Panel..................................................................................................... 17
3.2 Bus Panel...........................................................................................................18
3.3 Waveform Panel.................................................................................................20
3.4 Measurement Panel...........................................................................................22
3.5 Export Data........................................................................................................ 23
Chapter 4 Bus Plug-in .................................................................................24
4.1 Summary............................................................................................................25
4.2 Example............................................................................................................. 27
Chapter 5 Trigger.........................................................................................30
5.1 Base Trigger Setup............................................................................................31
5.2 Advance Trigger Setup.......................................................................................33
5.3 Immediately Trigger ...........................................................................................33
Appendix ......................................................................................................34
Hardware Specification............................................................................................35
Channels..................................................................................................................36
Block Diagram..........................................................................................................37
Cleaning and maintenance ...................................................................................... 38

Logic Analyzer
Hantek4032L
General safety summary
Understand the following safety precautions to avoid injuries and to prevent
damage to the product or the product of any product link. To avoid possible
dangers, be sure to use the product in accordance with the regulations.
Only qualified personnel to perform maintenance procedures.
Prevent fire and personal injury.
Use the right power cord. Only the country in which the authorized use of
this product for the power line.
Correctly inserted. Probe or test voltage wire connected to the source,
please do not plug.
Products will be grounded. This product through the power of the
grounding wire grounding. To avoid electric shocks, grounding conductor
must be connected to. In this connection the import or export of products
before the end, be sure to correct grounding for this product.
Properly connected probe. Probe the ground with the same potential. Do
not connect high-voltage ground.
See all the terminals rating. To avoid excessive current fire and the
impact, see the product of all the ratings and tags; please connect
products in the product manual inspection prior to understand the detailed
ratings information.
Do not run the product if you open the cover or panel.
Avoid the exposed circuit. Do not connect power after contact with the
exposed joints and components.
Suspected products to failure do not operate. If you suspect that this
product has been a failure, can be qualified maintenance personnel to be
checked.
Maintain proper ventilation.
Do not operate in the humid environment.
Do not flammable and explosive environment operation.
Please keep the product clean and dry surface.
User’sManual 1

Logic Analyzer
Hantek4032L
Introduction
The Hantek4032L is a sophisticated 32-channel logic analyzer used for testing,
analysis, and troubleshooting of digital circuits. It is equipped with features
found only in more expensive bench type instruments. The use of advanced
large-scale integrated circuits, integrated USB 2.0, CPLD, FPGA,
high-frequency digital circuitry, and other advanced technology, make the
Hantek4032L to be portable, and easy-to-use. The Hantek4032L is very
suitable for electronic measurement engineers, college students in scientific
research and development and teaching assistants.
The User’s Manual describes in detail the operation of the Hantek4032L as
well as installation of the software.
The device has a sufficient number of input channels and is capable of
simultaneously observing a lot of information or data flow direction control
information, and in some way of capturing narrow pulse interference.
It has the feature of delayed ability to capture the required observation points
around the waveform, in a variety of digital information capture function.
The Hantek4032L has intuitive and flexible displays to facilitate dynamic
analysis, can transform the information, and the user can use the binary,
decimal, hexadecimal or ASCII that information to facilitate the repair process
and debug.
It can be triggered in a variety of ways, can display a very long data stream, on
the basis of the analysis of that part of the information to make accurate
positioning, and capture appropriate information for software analysis by using
its tracking function trigger operation procedures. For hardware, trigger
function can be detected in the system and that the interference and Burr.
The Hantek4032L has reliable Burr detection ability. As competition in digital
circuit, the signal crosstalk, interference and power coupling factors, often
mixed with irregular signal in the burr, which will run from an incorrect circuit.
User’sManual 2

Logic Analyzer
Hantek4032L
Chapter 1 Getting started
This chapter focuses on the following topics:
System Requirements
Installing Software
Installing Driver
User Interface
User’sManual 3

Logic Analyzer
Hantek4032L
1.1 System Requirements
Minimum System Requirements
Operating System
Windows XP/Vista/Win 7
Memory
128MB
Graphic Card
Microsoft DirectX supported
Screen resolution: 1024x768
Color depth: 16bit
User’sManual 4

Logic Analyzer
Hantek4032L
1.2 Installing Software
1. While in Windows, insert the installation CD into the CD-ROM drive.
2. The installation should start up automatically. Otherwise in Windows
Explorer, switch to the CD-ROM drive and run "Setup.exe".
3. The Hantek4032L Installation is started. Click 'Next' to continue.
4. Choose a destination directory. Click 'Next' to continue.
User’sManual 5

Logic Analyzer
Hantek4032L
5. Check the setup information. Click Next to start copying of files.
6. This status dialog is displayed during copying of files.
User’sManual 6

Logic Analyzer
Hantek4032L
7. Updating Your System Configuration.
8. The installation is complete.
User’sManual 7

Logic Analyzer
Hantek4032L
1.3 Installing Driver
1. Connect the A-Type Plug of USB cable to your PC’s USB port.
2. Connect the B-Type Plug of USB cable to Hantek4032L’s USB port.
3. New hardware is found.
4. New hardware search wizard starts.
5. New hardware search wizard starts to search.
User’sManual 8

Logic Analyzer
Hantek4032L
6. New hardware wizard installs software.
User’sManual 9

Logic Analyzer
Hantek4032L
7. Finish new hardware search wizard.
Caution:
Do not disconnect any device from the USB bus while the computer is
communicating with the Hantek4032L, or you may lose data and/or your ability
to communicate with the device.
If the LED is illuminated but then turns off, the computer has lost
communication with the Hantek4032L.To restore communication, disconnect
the USB cable from the computer, and then reconnect is. This should restore
communication, and the LED should turn back on.
User’sManual 10

Logic Analyzer
Hantek4032L
1.4 User Interface
Hantek4032L provides users with a simple and full-featured interface so that
users needn’t spend a lot of time to learn.
At the same time, it provides control panel, waveform panel, bus panel,
measurement panel, trigger panel.
User’sManual 11

Logic Analyzer
Hantek4032L
Chapter 2 Menu
This chapter focuses on the following topics:
File
View
Setup
Analyzer
Help
User’sManual 12

Logic Analyzer
Hantek4032L
2.1 File
zExport As CSV File: Export data to file as “CSV”
zExport As TXT File: Export data to file as “TXT”
zExport As BMP File: Export data to file as “BMP”
zPrint…: Print the current waveform
zPrint Preview: Preview the current waveform
zPint Setup: Setupprinttype
zExit: Exit Hantek4032L
2.2 View
zToolbar: Show or hide the toolbar window
zStatus Bar: Showorhidethestatuswindow
zControl Window: Show or hide the control window
zMeasure Window: Show or hide the measure window
zZoom In: Enlargement waveform view
zZoom Out: Reduction waveform view
zZoom All: Show entire waveform view
User’sManual 13

Logic Analyzer
Hantek4032L
2.3 Setup
zSignal Name Setup: Modify the signal name.
zBus Setup: Configure the bus and signals.
zTrigger Setup: Configure the trigger condition.
2.4 Analyzer
zScroll to First Sample: Causes the waveform view to roll to the first
sample position
zScroll to Trigger: Causes the waveform view to roll to trigger
position.
zScroll to Last Sample: Causes the waveform view to roll to the last
sample position
zNew Mark: Create a new Mark
zNew Measurement: Create a new measurement.
zZoom In: Enlargement waveform view
zZoom Out: Reduction waveform view
zZoom All: Show entire waveform view
User’sManual 14

Logic Analyzer
Hantek4032L
2.5 Help
zHelp Content: Open the User Manual
zAbout: Show the copyright of the device
User’sManual 15

Logic Analyzer
Hantek4032L
Chapter 3 Advanced
This chapter focuses on the following topics:
Control Panel
Bus Panel
Waveform Panel
Measurement Panel
Export Data
User’sManual 16

Logic Analyzer
Hantek4032L
3.1 Control Panel
zHorizontal:
Set the clock and sample rate
Sample Rate: User can select the sample rate from 1MS/s to 400MS/s.
Sample Depth: User can set the sample depth 1k, 2k, 10k.
zThreshold:
Configure the input trigger level.
zTrigger:
Trigger Condition: Popup the trigger setup dialog.
Force Trigger: Trigger immediately once.
Stop: Stop trigger.
Single: Trigger under the trigger condition once.
User’sManual 17

Logic Analyzer
Hantek4032L
3.2 Bus Panel
Click the menu “Setup”-> “Bus Setup…” to open the dialog.
Hantek4032L has 32 signals channels, A0 ~A15, B0~B15. You can assign the
parts of them to some bus.
The list box contains all of the bus; you can add or delete the bus.
For example: Assign a bus “My Bus” which has 7 signals “A0, A1,A2, A3, A4,
A5 and A6”.
1. Click the button “Add”. Then a new bus is added to the list.
2. Click the pane under the A0, A1, A2, A3,A4, A5, and A6. If the pane is filled
of red, it means you have add the signal to the bus.
User’sManual 18
Table of contents
Other Hantek Measuring Instrument manuals

Hantek
Hantek DSO3062L User manual

Hantek
Hantek HT300B User manual

Hantek
Hantek DSO3102 User manual

Hantek
Hantek HT8000 Series User manual

Hantek
Hantek CC-800 User manual

Hantek
Hantek HSA2030 User manual

Hantek
Hantek Hantek2000 Series User manual

Hantek
Hantek HTM200 Series User manual

Hantek
Hantek 1832C User manual

Hantek
Hantek DSO8000 Series User manual