2
IMPORTANT SAFETY INSTRUCTIONS
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean the contaminated area on the product surface with a soft, dry cloth or a damp cloth.
(Do not use a detergent or cosmetic products that contain alcohol, solvents or surfactants or oil
constituents as they may deform or cause damage to the product.)
7. Do not block any ventilation openings, Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus
(including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has
two blades with one wider than the other. A grounding type plug has two blades and a third
grounding prong. The wide blade or the third prong are provided for your safety, If the provided
plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience recep-
tacles, and the point where they exit from the apparatus.
11. Only use attachments/ accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufac-
turer, or sold with the apparatus. When a cart is used, use caution when moving
the cart/apparatus combination to avoid injury from tip-over.
13.
Refer all servicing to qualified service personnel. Servicing is required when the
apparatus has been damaged in any way, such as power-supply cord or plug is
damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been
exposed to rain or moisture, does not operate normally, or has been dropped.
WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS
PROCUCT TO RAIN OR MOISTURE. DO NOT INSERT ANY METALLIC OBJECT
THROUGH THE VENTILATION GRILLS OR OTHER OPENNINGS ON THE
EQUIPMENT.
Apparatus shall not be exposed to dripping or splashing and that no objects filled with
liquids, such as vases, shall be placed on the apparatus.

3
CAUTION
CAUTION
RISK OF ELECTRIC SHOCK.
DO NOT OPEN
CAUTION : TO REDUCE THE RISK OF ELECTRIC SHOCK.
DO NOT REMOVE COVER (OR BACK).
NO USER SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
EXPLANATION OF GRAPHICAL SYMBOLS
The lightning flash with arrowhead symbol, within an equilateral
triangle, is intended to alert the user to the presence of “dangerous
voltage” within the product’s enclosure that may be of sufficient
magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert
the user to the presence of important operating and maintenance
(servicing) instructions in the literature accompanying the product.
Please read the following recommended safety precautions carefully.
yDo not place this apparatus on an uneven surface.
yDo not install on a surface where it is exposed to direct sunlight, near heating equipment or
heavy cold area.
yDo not place this apparatus near conductive material.
yDo not attempt to service this apparatus yourself.
yDo not place a glass of water on the product.
yDo not install near any magnetic sources.
yDo not block any ventilation openings.
yDo not place heavy items on the product.
yPlease wear protective gloves when installing/removing the product.
The high temperature of the product surface may cause a burn.
User’s Manual is a guidance book for how to use the products.
The meaning of the symbols are shown below.
yReference : In case of providing information for helping of product’s usages
yNotice : If there’s any possibility to occur any damages for the goods and human caused by
not following the instruction
Please read this manual for the safety before using of goods and keep it in the safe
place.

4
What’s Included
Quick Guide Warranty card (Optional) Hex screw
Hex columns Door lock key L Wrench
Battery securing band Washer flat
Installing the washer

5
Terminal block wiring
J `
Turn the AC power off to ensure safety when wiring terminal block for power supply.
`
Make sure to connect to the correct polarity (+ -) when connecting the battery to the power supply.
`
When producing, do not connect the download terminal of the power supply with test terminals.
a
Connect to the AC FAIL terminal of V100, V200, V300, V1000, and V2000
b
Connect to the BATT FAIL terminal of V100, V200, V300, V1000, and V2000
c
Connect to 12VDC (+, -) power input terminal of V100, V200, V300, V1000, and V2000 (note +, - polarity)
d
Connect to Lock’s DC 12V +, - power input terminal (note +, - polarity)
e
Connect to STROBE/HORN’s DC 12V +, - power input terminal (note +, - polarity)
f
Connect to Battery+, Battery- terminal of Battery (note +, - polarity)
g
When producing, do not connect with test terminals.
AC FAIL CHARGENON BATT CONTROLLER/INTERFACE LOCK STROBE/HORN
DOWNLOAD
a b f gc d e

6
TAMPER AC
FAIL
BAT
FAIL
P7
12VDC
IN
Allocate the electric current capacity for each terminal block
Item Information
CONTROLLER/INTERFACE(2Port),
LOCK(2Port)
3,200mA
STROBE/HORN(2Port)
800mA
CHARGE(1Port)
700mA
Wiring of case tamper switch
Connect to TAMPER terminal of V100, V200, V300, V1000, and V2000.
Wiring power cord
n`
Secure with the securing band when wiring power cord.
There is a risk of falling if it is not secured by the securing band.

7
Product Specifications
Item Information
SMPS
Terminal Interface
AC FAIL(+,-)1Port, NON_BATT(+,-)1Port, CONTROLLER/INTERFACE
(+,-)2Port, LOCK(+,-)2Port, STROBE/HORN(+,-)2Port, CHARGE(+,-)1Port
Operation Temperature
0°C ~ +45°C (+32°F ~ +113°F)
Input Power
Rated 100~240VAC(50Hz/60Hz) / 2.0A
Power Consumption
Rated 13.5V±5%, 4.7A (However, DC 12.5V ±5% is used for strobe and horn terminal)
Compatible battery
12V, 18Ah, Rechargeable
Battery Backup
In the event of a power outage, make a battery backup by converting the power supply
from AC to DC
SMPS Status Transmission
Transmit the signal for AC loss and battery fail (non battery-check whether battery exists
or not in the initial run) to controller/interface board
Battery Overcharge Protection
Protect the battery by limiting the backup battery usage to 10.8V
Certificate
CE, KC
MAX. Power consumption (W)
83W (SMPS output 13.5V / 4A + Battery 0.7A charging)
ENCLOSURE
Dimension(mm) (W x L x D)
W 410 x L 410 x D 97
Battery Fixture
Provide the band to secure the battery
Case Lock
Provide protection using the housing case lock
Case Status Transmission
When the case opens, transmit the signal for case tampering to the controller/interface
board
CONTROLLER/INTERFACE Onboard
Provide a loading board of 2EA Max (2-layer stack structure)

Table of contents
Popular IP Access Controllers manuals by other brands

Tyco Security Products
Tyco Security Products Software House IP-ACM quick start guide

Intelligent Building Solutions
Intelligent Building Solutions CAP 2020 DR IB installation manual

Roger
Roger MC16 installation manual

Nice
Nice EPad manual

NetComm
NetComm IAC4000 Specifications

Clarion
Clarion TF1700 user manual