V220322
Graphic Display Multi-Function Proximity
Controller (with Temperature Module)
O. Alarm Clock (for Factory)
Hardware installation
M1
Board
Horn M2
1
2
3
4
5
6
7
8
N.C.
N.O.
COM
CTL
12V
ALM
12V
GND
GND
P1
Output to M1 and M2
Mike device
Mike device
Music Box
Music Box Mike's sound wire
Mike's sound wire
DC 12V Relay Board
Controller
POWER
12VDC
Access programming mode → Tools → Daily Alarm → Set (00~15) → Set Start Tm (24 Hours) ; Set Eect Sec.
(Seconds as the bell time, Range:1~255) → Set Weekday (0:disable, 1: enable) → Succeeded
5 9
N. Lift control
[e.g.] Connect with AR-401-IO-0016R to control which oor the user will be able to access. (BAUD9600)
Access programming mode → Tools → Terminal Port → 0
:
Lift Controller → Baud Selection 0
: 9600
5 4
Setting Lift control
Access programming mode → User Setting → Single Floor →
Input 5-digit user address → Input single oor number: 1~64
2 4
Single oor
Access programming mode → User Setting → Multi Floor → Input 5-digit user address → Select range: 1 or 2 or 3 or 4 → Input 16 digits
multi oors number [0:disable, 1: enable]
[e.g.] Set NO. 114, can use it through the 8 F and 16F:
Access programming mode → User Setting → Multi Floor → 114 → 1 → 0000000100000001
2
2
5
5
Multi oors
Set Floor/ Stop
1
0
17
0
33
0
49
0
9
0
25
0
41
0
57
0
1
2
3
4
3
0
19
0
35
0
51
0
11
0
27
0
43
0
59
0
2
0
18
0
34
0
50
0
10
0
26
0
42
0
58
0
4
0
20
0
36
0
52
0
12
0
28
0
44
0
60
0
5
0
21
0
37
0
53
0
13
0
29
0
45
0
61
0
6
0
22
0
38
0
54
0
14
0
30
0
46
0
62
0
7
0
23
0
39
0
55
0
15
0
31
0
47
0
63
0
8
1
24
0
40
0
56
0
16
1
32
0
48
0
64
0
Access programming mode → Tools → Terminal Port → 1
:
Lift Controller
(need to use AR-321L485-5V)
5 5
While connecting with AR-721-U, AR-737-H/U(WG mode) and AR-661-U for anti-pass-back function, the access mode must be "Card" only.
M. Anti-pass-back
Device enable
Access programming mode → Parameters[2] → Anti-pass-back → master controller select [1: Yes] → WG select [1: Yes]
4 6
Card user enable
Access programming mode → Add/ Delete → Antipass Group → Input 5-digit starting user address → Input 5-digit ending user
address → must select [1: Yes]
1 9
Enable/Disable the arming status:
Standby Mode
Access Programming mode
Card only Card or PIN Card and PIN
Open the door
Present the tag to reader → Input
4-digit arming PWD →
Input user address → Input
4-digit individual PWD → →
Input 4-digit arming PWD →
Present the tag to reader → Input
4-digit individual PWD → →
Input 4-digit arming PWD →
Enable: Access programming mode → Quit & Arming
7Disable: Access programming mode → Quit
6
No open the door
→ Input 4-digit arming PWD
→ Present the tag to reader
※ [Use FP] can substitute for [Induct valid card].