E. Non-Combustible Materials Specication
Materialwhichwillnotigniteandburn.Suchmaterialsare
thoseconsistingentirelyofsteel,iron,brick,tile,concrete,
slate,glassorplasters,oranycombinationthereof.
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in
a Vertical Tube Furnace at 750° C and UL763 shall be
considerednon-combustiblematerials.
F. Combustible Materials Specication
Materials made of or surfaced with wood, compressed
paper,plantbers,plastics,orothermaterialthatcanignite
andburn,whetherameproofedornot,orplasteredorun-
plasteredshallbeconsideredcombustiblematerials.
G. Electrical Codes
120VAC,60Hz,Start4.2Amps,Run2.8Amps
NOTE: Some generator or battery back-up systems may
not be compatible with the micro-processor electronics
on this appliance. Please consult the power supply
manufacturer for compatible systems.
WARNING! Risk of Fire! Hearth & Home Technologies
disclaimsanyresponsibilityfor,andthewarrantyandagency
listingwillbevoidedbythebelowactions.
DO NOT:
• Installoroperatedamagedappliance
• Modifyappliance
• Install other than as instructed by Hearth & Home
Technologies
• Operate the appliance without fully assembling all
components
• Overre
• Install any component not approved by Hearth &
HomeTechnologies
• InstallpartsorcomponentsnotListedorapproved.
• Disablesafetyswitches
Improper installation, adjustment, alteration, service or
maintenancecancauseinjuryorpropertydamage.
Forassistanceoradditionalinformation,consultaqualied
installer,serviceagencyoryourdealer.
D. BTU & Efciency Specications
*AnefciencybasedonEPAhistoricaldataof78%
**ActualtestedHigherHeatingValue(HHV)efciencyand
datacollectedduringEPAemissionstest
***ArangeofBTUoutputsbasedonEPAdefaultefciency
andtheburnratesfromthelowandhighEPAtests
****Basedonthemaximumfeedrateperhourmultipliedby
approximately8,600BTU’swhichistheaverageBTU’sfrom
apoundofpellets.
Thiswoodheaterneedsperiodicinspectionandrepairfor
properoperation.Itisagainstfederalregulationstooperate
this wood heater in a manner inconsistent with operating
instructionsinthismanual.
P43 Freestanding Pellet Stove:
EPA Certication Number: 945-14
EPA Certied Emissions: 1.3g/hr
*EPA Default Efciency: 78%
**Actual Tested Efciency: 69.5%
***EPA BTU Output: 31,300
****BTU Input 43,000
Vent Size: 3Inch
Hopper Capacity: 50lbs
Fuel WoodPellet
P61A Freestanding Pellet Stove:
EPA Certication Number: 966-14
EPA Certied Emissions: 1.7g/hr
*EPA Default Efciency: 78%
**Actual Tested Efciency: 73.5%
***EPA BTU Output: 45,100
****BTU Input 61,000
Vent Size: 3Inch
Hopper Capacity: 72lbs
Fuel WoodPellet
P68 Freestanding Pellet Stove:
EPA Certication Number: 963-14
EPA Certied Emissions: 1.3g/hr
*EPA Default Efciency: 78%
**Actual Tested Efciency: 72.7%
***EPA BTU Output: 53,500
****BTU Input 68,000
Vent Size: 3Inch
Hopper Capacity: 76lbs
Fuel WoodPellet