Haseman Electric RS-10PM2 User manual

HASEMAN ELECTRIC
RS-10PM2
USER MANUAL
Haseman RS-10PM2 is a 10-channel, DIN Rail,
Relay module with true RMS energy meter,
produced by using -Wave Plus, the latest version
of -Wave.
RS-10PM2 is optically isolated and protected
against voltage surges, caused by switching of
inductive and capacitive loads as power contactors,
motors, EM valves and switching power supplies.
ero-cross switching technology ensures high
reliability and long relay life.
WHAT IS Z-WAVE?
-Wave is an international standard protocol for
wireless communication in smart homes and
building systems. It enables smart home products
to talk to each other and creates the backbone of
your smart home. -Wave based system allows you
to use your smartphone or tablet to create one-
touch scenes that help with your daily activities:
saving energy, keeping your home secure and
being more comfortable.
-Wave technology is simple: each transmitted
message is reconfirmed (2-way communication)
and every mains powered device can act as a
repeater for other devices (mesh network). The
more -Wave products you have in your smart
home, the stronger your smart home network is.
-Wave technology is the leading solution in smart
home automation. There is a wide range of -Wave
devices that are compatible, independently of the
manufacturer which gives the system an ability to
evolve and expand over time.
SAFETY INFORMATION
Read this manual before attempting to install the
device! Failure to observe recommendations
included in this manual may be dangerous or cause
a violation of the law.
The manufacturer will not be held responsible for
any loss or damage resulting from not following the
instructions of operating manual.
DANGER OF ELECTROCUTION!
All works on the device may be performed
only by a qualified and licensed electrician.
Observe national regulations.
The device is designed to operate in electrical
home installation. Faulty connection or use may
result in fire or electric shock.
Even when the device is turned off, voltage may
be present at its terminals.
Any maintenance introducing changes into the
configuration of connections or the load must be
always performed with disabled fuse.
CONNECTION DIAGRAMS
When connecting the module, observe the
proper Neutral (N) and Line (L) terminals.
Only the provided current clamp can be
connected to Input terminals CT1 and CT2.
Each relay channel has its own Input (In)
and Output (O), which allows controlling of
devices, supplied by different voltages (12,
24, 48VDC / VAC, 110-240 VAC, etc.)
INSTALLATION
Mount the module on standard DIN Rail.
Connect the controlled lines. Depending on the
load supply voltage, use one of the following
connection diagrams:
For 2 0 VAC Loads:
For low voltage AC/DC Loads:
During operation, each channel
status is indicated by panel
indication LED.
Connect the local control lines S1 to S10 (
if local
control is used).
Depending on the BUTTON TYPE
Parameter (separate for each Channel), Push
Buttons or Toggle Switches can be connected:
Only Voltage Free contacts must be
connected between terminal Com and
terminals S1 to S10.
Connect the Current clamp to inputs CT1-CT2
and
fix it on the monitored power line.
Connect the supply to Neutral and Line terminals
and wait for 30 second until the module
initialization
process is completed.

Z-WAVE NETWORK
-Wave uses a mesh network topology where any
non-battery powered device acts as a signal
repeater, enabling reliable connections from one
node to the other. Battery powered devices do not
act as repeaters as this would result in high levels
of battery drain.
The frequencies used for -Wave are below that of
the normal Wi-Fi band and this enables better
penetration of walls and other items found in all
homes, but in addition to this, the mesh network
means that the transferred data can intelligently
routed by the network to get around obstacles and
thereby obtaining robust whole-home coverage.
-Wave typically has a range of about 50 meters in
open air. However walls and other items in the
home will considerably reduce this and therefore it
is recommended that the maximum device spacing
-Wave network is around 10 meters. Anything
closer will provide better communications.
In order to have a hierarchy within a wireless
network, various types of -Wave device are
specified:
Controller: As the name implies, these devices are
those that control other -Wave devices. Controller
devices are factory programmed with a Home ID
which cannot be changed by the user.
Slave: Slave devices are those that are controlled
by controllers. Slave devices do not have a pre-
programmed Home ID, but instead they take the
Home ID assigned to them by the -Wave network
controller.
Routing slave: This form of -Wave slave is one
that knows its neighbors and has partial knowledge
of routing table. It can reply to the node from
which it has received the message. It can also send
unsolicited messages to a number of predefined
nodes to which it has routes.
-Wave networks can be linked together for even
larger deployments. Each -Wave network can
support up to 232 -Wave devices allowing the
flexibility to provide sufficient devices for a
complete automated home.
Z-WAVE NETWORK
INCLUSION / EXCLUSION
On factory default the device does not belong to
any -Wave network. The device needs to be
added to an existing wireless network to
communicate with the devices of this network. This
process is called Inclusion. Devices can also be
removed from the network. This process is called
Exclusion. Both processes are initiated by the
primary controller of the -Wave network. This
controller is turned into exclusion respective
inclusion mode. Inclusion and Exclusion is then
performed doing a special manual action right on
the device.
INCLUSION
Bring the module at max. 1 meter distance
from the main controller.
Connect the module to power supply.
Set the -Wave controller into INCLUSION
mode (adding new device to the Network).
Triple click the -Button on the front panel.
Be patient until the inclusion process is
completely finished. Multichannel
devices usually need a bit more time
for complete configuration.
After the inclusion, it will appear a separate
instance (Node) for each relay channel as well as
additional nodes for the network Voltage, and
Frequency, Instant Current, Active Power, Power
Factor and Energy Usage. You can hide
unwanted Nodes and rename those which you
need. Depending on the model of your main
controller, you can also edit Node icons in order
to suit your current project needs.
EXCLUSION
Bring the module at max. 1 meter distance
from the main controller.
Connect the module to power supply.
Set the -Wave controller into EXCLUSION
mode (remove device from -Wave Network).
Triple click the -Button on the front panel.
After the EXCLUSION, all user
configuration parameters of the
module will be automatically set to
their default values.
CONFIGURATION PARAMETERS
This -Wave product is designed to work out of the
box after inclusion. However certain configuration
can customize its functionality and fit it to your
specific project needs.
Configuration parameters are
accessible from the main controller
User Interface (UI). You should find
detailed instruction on configuration
procedure into your main controller
User Manual.
When proceeding with parameter modification,
please refer to the parameter Range and Data
Type, as they are specified below:
Reporting time
Minimum time interval between power meter
data reports.
Parameter No: 11
Data type: 1 byte
Default value: 30 sec
Range: 1 – 255 sec
Decreasing the reporting time to less than
5 seconds could flood your -Wave
network, strongly impacting the network
communication.
Power Up Memory
When Power Up memory is active, the module will
save actual status of all outputs in case of power
break. After restoring the supply, all outputs will be
switched to their previously saved statuses.
Parameter No: 64
Data type: 2 bytes
Default value: 0 (inactive)
Available Settings:
1 – Active
0 (or any other number) - Inactive
Button Type (separate for each channel)
Parameters No: 65 to 74 (for Channel 1 to 10)
Data type: 2 bytes
Default value: 1
Available Settings:
1 – PUSH BUTTON (Each push is changing the
output status from ON to OFF, or vice versa).
2 – TOGGLE SWITCH (Each changing the
switch position will change the Output between ON
and OFF statuses).
– FOLLOWER SWITCH (The output is
following the status of the switch: open switch –
inactive output, closed switch – active output).
ANY OTHER number will disable the local
control of this channel (remote control over the
-Wave network will remain active).

ASSOCIATIONS
Associations provide direct control of other
devices within the -Wave network, using the
switches, connected to the module inputs.
ASSOCIATION GROUPS:
Association Group 1 (Lifeline)
Reports state of the device.
The main -Wave+ network controller is added to
this group by default. It is not recommended to
modify this group.
Association Groups 2 to 11 (User Groups 1 to
10) are assigned to switches S1 to S10.
The module sends BASIC command class frame
(On/Off), following the state of the corresponding
Output 1 to Output 10 (behavior depends on the
value of the configuration parameter for the
Button Input type (parameter 65 to 73, individual
for each channel).
Association ensures direct transfer of
control commands between devices, i.e.
it is performed without participation of
the main controller and requires
associated device to be in a direct range.
Sample configuration screens and module views in
-Way UI.
Sample configuration screens and module views
in Fibaro Home Center UI:
Configuring of polling time interval :
Sample views of RS10-PM power data in Fibaro
Home Center Energy Panels – (Current Energy
and Historical Data):

ENCLOSURE DIMENSIONS (mm)
DIN RAIL MOUNTING
CLAMP DIMENSIONS (mm)
ACCURACY
Power network parameters are measured out by the
most advanced True RMS measuring technology
assuring maximum accuracy and precision (±1% for
loads greater than 4.8W).
Power measurement takes into account all
actual fluctuations of the Mains voltage.
Energy Usage
data is saved into nonvolatile
memory of the module at any 1 kWh and will
be automatically restored in case of power
breaks. After excluding the module from the -
Wave
network, Energy Usage record will reset to 0.
COMMAND CLASSES
• Basic • Switch Binary • Sensor Multilevel
• Meter • Association Group Information
• Device Reset Locally • -Wave Plus Info
• Multi Channel • Configuration
• Manufacturer Specific • Power Level
• Firmware Update • Association • Version
• Multi Channel Association
WARRANTY
We warrant that the device is free from defects in
parts and workmanship under normal use for 24
months from date of purchase. The original
purchase invoice or sales receipt is the proof of
date of purchase by the Customer.
If the Device has manufacturing defects or in any
case of alleged lack of conformity, the Customer
shall send a claim. Once we receive the Warranty
Claim, we must inform the Customer if the
Warranty is applicable and the address where the
Device shall be sent in order to verify the defects
(if any). The Device shall be sent by the Customer
at its own costs and expenses, and with the
original packaging, the supplied accessories and
documents proving date of purchase. We must
then inform the Customer about the defects and on
its repair or replacement (where applicable). The
Warranty Period of the replaced or repaired Device
shall not be extended. We will ship the repaired or
a replaced Device to Customer freight prepaid. We
will not be liable for damages to property caused
by faulty device. We will not be liable for indirect,
incidental, special, consequential or punitive
damages, or for any damage, including, inter alia,
loss of profits, savings, data, loss of benefits,
claims by third parties and any property damage or
personal injuries arising from or related to the use
of the Device. If the Device cannot be replaced
with another of the same type (e.g. the Device is
no longer in production or no longer available for
selling in the Customer’s country), it may be
replaced with a different one having similar
technical specifications to the faulty one. Such
replacement shall be considered as a total
fulfillment of our obligations.
Warranty exclusion:
- Defects caused by normal wear of parts or
especially subject to wear, such as parts that
require periodic replacement during the normal
operation of the system;
- Splits, cracks, scratches, dents, scratched or
discolored surfaces and parts, breakage of plastic
parts and any other cosmetic damage;
- Damages resulting from use of the system other
than that provided, including but not limited to the
failure to follow instructions contained in the
operating manual;
- Damages caused by accident, abuse, misuse,
dirt, viruses, liquid contact, fire, earthquake,
improper or inadequate maintenance or calibration,
negligence or other external causes;
- Environmental damage and / or defects caused
by smoke, dust, dirt, soot, or other external
influences;
- Damages caused by modifications and alterations
in the functionality or features;
- Damages resulting from transportation or
inadequate packaging when returning the product
to an authorize service center;
- Damages resulting from surges in the power
and/or telecommunication network, improper
connection to the grid in a manner inconsistent
with the operating manual, or from connecting
other devices not recommended by the maker;
- Damages caused by operating or storing the
device in extremely adverse conditions, i.e. high
humidity, dust, too low (freezing) or too high
ambient temperature;
- Products whose warranty sticker has been
removed, damaged or rendered illegible;
- Expiration of the Warranty Period.
If a defect is not covered by the Warranty, we will
inform the Customer about the extra expenses for
the repair or replacement.
TECHNICAL SPECIFICATIONS
10 Independent Relay Outputs
Optically-isolated, surge protected
ero Cross relay switching
Capable to control AC and/or DC loads
Wide Power Supply range: 110-240VAC, 50/60Hz
Max. AC output: 10A / 110-230V (resistive load)
Max. DC output: 12A / 12-30VDC
Durable relays with long life contact system
16A rated PCB power tracks and terminals
Front panel LED indication of active outputs
User configurable Power Up Memory function
User configurable parameters for button type –
push button, toggle switch or follower switch
(individual setting for each channel)
True RMS Power meter with 60A current clamp
(included), reporting all power data to the -Wave
controller (True RMS Voltage, Frequency, Current,
Instant Active Power, Power Factor and Energy
Usage)
ABS enclosure for standard DIN Rail mounting
Dimensions: 105 x 86 x 57mm
Durable tactile buttons on the front panel
Conforms to EU regulations: EN55022 EN610006
Radio protocol: -Wave Plus, GEN 5, 868.42MHz
Antenna range: up to 50m outdoor / 30m indoor
DISPOSAL GUIDELINES
The product does not contain hazardous chemicals.
Do not dispose of electrical appliances as
unsorted municipal waste, use separate
collection facilities. Contact your local
government for information regarding
the collection systems available.